Code: 11C11??? Display: 11C11??? Used by: QP242,QP201,QP202,QP203,QP132 (??? indicates the sequence number (in hexadecimal).) (For sequences above 4096, 4096 is displayed.) Cause: An x coordinate in sequence data is out …

100%1 / 5282
another device.
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Check and correct the data item combination D_data TU and D_data TM in the production
program.
------------------------------
Code: 11C06???
Display: 11C06???
Used by: QP132
Cause: There is an unspecified next device in the next device loop.
??? indicates the sequence number (in hexadecimal).
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Check the next device loop of the appropriate sequence in the production program. Specify the
next device in Next.
------------------------------
Code: 11C07???
Display: 11C07???
Used by: QP132
Cause: The next device station number is different from the first device.
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Specify correct data for Next in the production program's D_data.
------------------------------
Code: 11C08???
Display: 11C08???
Used by: QP132
Cause: The loop does not close even though the next device nest has exceeded 30 (12 for the QP132).
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Check the next device loop of the appropriate sequence. Change Next in D_data so that the loop
closes within 30 devices (within 12 for the QP132).
------------------------------
Code: 11C0A???
Display: Same as Code.
Used by: QP132
Cause: The device comment of the device used by the specified sequence, is not set. This setting must be
made for the QP132.
("???" represents the sequence number in hexadecimal format. However, if the sequence number is 4096
or greater, subtract 4096.)
Remedy: Set the device comment.
------------------------------
Code: 11C10???
Display: 11C10???
Used by: QP242,QP201,QP202,QP203,QP132
Cause: An x coordinate in sequence data is out of range in the minus direction (for example placing area
or movement range).
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Specify correct data for X in the production program's N_data.
------------------------------
第 275 页
Code: 11C11???
Display: 11C11???
Used by: QP242,QP201,QP202,QP203,QP132
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Cause: An x coordinate in sequence data is out of range in the plus direction (for example placing area or
movement range).
Remedy: Specify correct data for X in the production program's N_data.
------------------------------
Code: 11C12???
Display: 11C12???
Used by: QP242,QP201,QP202,QP203,QP132
Cause: An y coordinate in sequence data is out of range in the minus direction (for example placing area
or movement range).
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Specify correct data for Y in the production program's N_data.
------------------------------
Code: 11C13???
Display: 11C13???
Used by: QP242,QP201,QP202,QP203,QP132
Cause: An y coordinate in sequence data is out of range in the plus direction (for example placing area or
movement range).
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Specify correct data for Y in the production program's N_data.
------------------------------
Code: 11C20???
Display: 11C20???
??? represents the sequence number (in hexadecimal).
For sequences above 4096, 4096 is displayed.
Used by: QP242,QP201,QP202,QP203
Cause: The main mark or the submark which is referred to by this sequence is not in the production
program, or has been skipped.
Remedy: Check the mark numbers at the placement sequence in question and the main and submark
numbers at the mark sequences.
------------------------------
Code: 11C21???
Display: 11C21???
??? represents the sequence number (in hexadecimal).
For sequences above 4096, 4096 is displayed.
Used by: QP242,IP3
Cause: The referenced main and sub marks for the sequence in question are set to the same number.
Remedy: Check the main and sub mark numbers.
------------------------------
Code: 11C22???
Display: 11C22???
??? represents the sequence number (in hexadecimal).
For sequences above 4096, 4096 is displayed.
Used by: QP242,IP3
Cause: The referenced main and sub marks for the sequence in question are set to the same coordinates.
第 276 页
Remedy: Check the main and sub mark coordinates.
------------------------------
Code: 11C30001
Display: 11C30001
Used by: CP7,QP3,NP1,NP2
Cause: More than one 2Dmark exists in Board.
Remedy: Check the 2Dmark sequence in the Recipe.
------------------------------
Code: 11C30002
Display: 11C30002
Used by: CP7,QP3,NP1,NP2
Cause: The Panel ID or the Board ID which is referred to by this sequence
is not in the production program, or has been skipped.
Remedy: Change the 2Dmark sequence before the placement sequence.
------------------------------
Code: 11CE0???
Display: 11CE0???(QP1)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The module number for the specified sequence is out of range.
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Input a module number which is within the specified range.
------------------------------
Code: 11CE1???
Display: 11CE1???(QP1)
Used by: QP132
Cause: The module number for the specified sequence is out of range.
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Either specify 105. Working Module in Proper data or change the module number.
------------------------------
Code: 11D00???
Display: 11D00???
Used by:
Cause: A device number is out of range. This error also occurs if device numbers used by the MTU1 are
set even though the machine is not equipped with an MTU1.
(The first number in ??? indicates the station number (in hexadecimal).)
(The following two numbers indicate the device number in that station.)
(For device numbers above 256, 256 is displayed.)
Remedy: Change the number of the devices which are located on the MFU.
Specify correct data for D in the production program's N_data.
If the machine is equipped with an MTU1, change Machine_Status B in Proper data (for the FIP3 and FLT)
as follows:
Machine_Status B: **** **** **** 1*** (MTU1),
Machine_Status B: **** **** ***1 **** (MTU2).
The data represented by * should not be changed from its present setting.(FIP3,FLT)
------------------------------
Code: 11D06???
Display: 11D06???
Used by: CP4-1,CP4-2,CP4-3,QP242,QP201,QP202,QP203,QP132
Cause: There is an unspecified next device in the next device loop.