FUJI错误代码查询.pdf - 第493页
Code: 12050112 Display: Btm Cleaner Position Error Used by: GP551 Cause: The lower cleaner tray is not in the locked position. Remedy: Move the lower cleaner tray to the locked position. ------------------------------ Co…
the table.Move the table to the loading position and ensure that the upper and lower sensors work
properly by performing the lifter up/down command and performing an I/O check.
------------------------------
Code: 1205010B
Display: "Interlock: camera" (GP-6)
Used by: GP551,GP6
Cause: The Z-axis and X-axis are in the interference zone, or are interfering with each other. This error
may also be caused by a sensor error.
Remedy: If the Z-axis and Y-axis are interfering with each other, manually move the X-axis until the X-
axis escape position check sensor (X03D: X ESC POS CHK) is tripped. If they are in the interference zone,
or if there is no interference, check the X-axis escape position check sensor (X03D: X ESC POS CHK) and
the Z-axis camera interference prevention check sensor (X03C: Z ESC POS CHK).
------------------------------
Code: 1205010C
Display: Interlock Sqg/Cleaner Head
Used by:
Cause: This error occurs when both the upper cleaning head and the squeegee are in the lowered
position.
Remedy: Raise the cleaning head or the squeegee holder. Alternatively, check the following sensors:
(X070: (F) SQG HLDR UP, X078: R SQG HLDR UP) or (X07C: TP CLR OPN CHK, X05A: LW CLR OPN CHK).
------------------------------
Code: 1205010E
Display: Sqg Head Unlock
Used by: GP551,GP6
Cause: The squeegee head has been opened.
Remedy: Close and lock the squeegee head.
------------------------------
Code: 1205010F
Display: "Parking Position Error"
Used by: GP551,GP6
Cause: When a parking command is executed, the squeegee head is down after the S-axis has moved to
the position specified in the Proper data and the squeegee parking position check sensor (X03F) has
turned on. This error occurs when the squeegee parking position check sensor remains off after the S-axis
has moved.
Remedy: Check the position detected by the parking position check sensor and the position specified by
the "Parking Position S" parameter in the Proper data.These should be adjusted so that the sensor turns
on when the S-axis arrives at the parking position, and the squeegee head comes to rest on the screen
support when it is down.
------------------------------
Code: 12050110
Display: Sqg Head Position Error
Used by: GP551
Cause: The squeegee head is not in the locked position.
Remedy: Ensure that the squeegee head is in the locked position.
------------------------------
Code: 12050111
Display: Top Cleaner Position Error
Used by: GP551
Cause: The top cleaner swing bar is not in the locked position.
Remedy: Move the top cleaner swing bar to the locked position.
------------------------------
第 492 页
Code: 12050112
Display: Btm Cleaner Position Error
Used by: GP551
Cause: The lower cleaner tray is not in the locked position.
Remedy: Move the lower cleaner tray to the locked position.
------------------------------
Code: 12050113
Display: 印刷位置无网板
[Conf scr at print pos now]
Used by: GPX,NXTP
Cause: 印刷位置上没有网板。
Remedy: 请在印刷位置上设置网板。
<img src="$LKEY_ERRIMG_MC$/12050113.PNG">
------------------------------
Code: 12050114
Display: Warning! Top Cleaner may damage solder roll
Used by: GP551
Cause: On machines with double squeegees, solder may be present on the screen. During automatic
operation, cleaning of both sides cannot be performed.
Remedy: In Proper data, set the cleaning method to not use the upper cleaning unit.
------------------------------
Code: 12050115
Display: Placing head 1 nozzle has become detached.
Used by: IP3
Cause: The nozzle at placing head 1 has become detached.
Remedy: Remove the detached nozzle from within the machine. Either reattach the nozzle to the head by
hand, or set the nozzle in the nozzle change unit and use the [NOZZLE] -[CHANGE] commands to perform
reattachment.
------------------------------
Code: 12050116
Display: Placing head 2 nozzle has become detached.
Used by: IP3
Cause: The nozzle at placing head 2 has become detached.
Remedy: Remove the detached nozzle from within the machine. Either reattach the nozzle to the head by
hand, or set the nozzle in the nozzle change unit and use the [NOZZLE] -[CHANGE] commands to perform
reattachment.
------------------------------
Code: 12050117
Display: 传感器检测出挡块不可下降错误
Used by: NXTP
Cause: 因为传感器检测出电路板,所以不能降低挡块。
Remedy: 1.请清除电路板。
2.请调整传感器。
<img src="$LKEY_ERRIMG_MC$/12050117.PNG">
------------------------------
Code: 1205012?
Display: Nozzle damage has been detected on head 1.
Used by: NP133,NP134,NP153
Cause: The nozzle bend check sensor at head 1, 13ST has detected a nozzle error. The question mark (?)
indicates the nozzle position. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Replace the nozzle, either manually or using the nozzle change command.
第 493 页
------------------------------
Code: 1205013?
Display: Nozzle damage has been detected on head 2.
Used by: NP133,NP134,NP153
Cause: The nozzle bend check sensor at head 2, 13ST has detected a nozzle error. The question mark (?)
indicates the nozzle position. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Replace the nozzle, either manually or using the nozzle change command.
------------------------------
Code: 1205014?
Display: A nozzle error has been detected at head 1, 16ST.
Used by: NP133,NP134,NP153
Cause: The nozzle check sensor at head 1, 16ST has detected a nozzle position error. The question mark
(?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. The nozzle may be stuck.
------------------------------
Code: 1205015?
Display: A nozzle error has been detected at head 2, 16ST.
Used by: NP133,NP134,NP153
Cause: The nozzle check sensor at head 2, 16ST has detected a nozzle position error. The question mark
(?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. The nozzle may be stuck.
------------------------------
Code: 1205016?
Display: A nozzle catch error has been detected at head 1, 1ST.
Used by: NP133,NP134,NP153
Cause: The nozzle catch check sensor at head 1, 1ST has detected a nozzle catch error. The question
mark (?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. In some cases a nozzle catch error occurs
when the nozzle is stuck.
------------------------------
Code: 1205017?
Display: A nozzle catch error has been detected at head 2, 1ST.
Used by: NP133,NP134,NP153
Cause: The nozzle catch check sensor at head 2, 1ST has detected a nozzle catch error. The question
mark (?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. In some cases a nozzle catch error occurs
when the nozzle is stuck.
------------------------------
Code: 12050180
Display: A vacuum pump thermal error has been detected.
Used by: NP133,NP134,NP153
Cause: The vacuum pump power source breaker was switched.
Remedy: Inspect the vacuum pump motor, the 200V main power source, and their connections.
------------------------------
Code: 12050181
Display: Shutter 1 Alarm
Upper limit sensor error
Used by: CP4,CP42,CP43,CP6,CP6M,CP65,CP642,CP642M,CP643
Cause: An alarm has occurred at the upper-limit sensor for the shutter of the D1-axis.
Remedy: Check the upper-limit sensor for the shutter of the D1-axis.
------------------------------
第 494 页