Code: 1D65B6??
Display:
Used by:
Cause: There is a lead where there ought not to be one on the upper side of the part. The final two digits
indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65B7??
Display:
Used by:
Cause: There is no lead where there ought to be one on the upper side of the part. The final two digits
indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65C0??
Display:
Used by:
Cause: A lead could not be detected on the left side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65C1??
Display:
Used by:
Cause: A lead could not be detected on the lower side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65C2??
Display:
Used by:
Cause: A lead could not be detected on the right side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65C3??
Display:
Used by:
Cause: A lead could not be detected on the upper side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65C4??
Display:
Used by:
Cause: An edge could not be detected on the left side of the part.
第 1772 页
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65C5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65C6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65C7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65D000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D65D080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D65E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D660002
Display:
第 1773 页
Used by:
Cause: Unable to pick parts.
Remedy: Replenish the parts supply.
------------------------------
Code: 1D660003
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660004
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660005
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660006
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660007
Display:
Used by:
Cause: Vision processing could not take a normal image. The upper or lower areas were too uneven or
there was foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D660008
Display:
Used by:
Cause: Vision processing could not take a normal image. The upper or lower areas were too uneven or
there was foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D660009
Display:
Used by: