------------------------------ Code: 1101C07F Display: Used by: Cause: There are over 30 next devices and the loop does not close. This error applies to device numbers 301 to 500. Remedy: Change the settings in "Nex…

100%1 / 5282
specified for another device. This error applies to sequences 51 to 100.
Remedy: Check that "TU" and "TM" in D_data in the production program match, and that the data is
correct.
------------------------------
Code: 1101C078
Display:
Used by: IP3
Cause: The next device has not been specified. This error applies to device numbers 1 to 50.
Remedy: Specify a next device in "Next" in the production program.
------------------------------
Code: 1101C079
Display:
Used by:
Cause: The next device has not been specified. This error applies to device numbers 51 to 100.
Remedy: Specify a next device in "Next" in the production program.
------------------------------
Code: 1101C07A
Display:
Used by:
Cause: The next device has not been specified. This error applies to device numbers 101 to 300.
Remedy: Specify a next device in "Next" in D_Data in the production program.
------------------------------
Code: 1101C07B
Display:
Used by:
Cause: The next device has not been specified. This error applies to device numbers 301 to 500.
Remedy: Specify a next device in "Next" in D_data in the production program.
------------------------------
Code: 1101C07C
Display:
Used by: IP3
Cause: There are over 30 next devices and the loop does not close. This error applies to device numbers
1 to 50.
Remedy: Change the settings in "Next" in the production program so that the loop closes within 30
devices.
------------------------------
Code: 1101C07D
Display:
Used by:
Cause: There are over 30 next devices and the loop does not close. This error applies to device numbers
51 to 100.
Remedy: Change the settings in "Next" in the production program so that the loop closes within 30
devices.
------------------------------
Code: 1101C07E
Display:
Used by:
Cause: There are over 30 next devices and the loop does not close. This error applies to device numbers
101 to 300.
Remedy: Change the settings in "Next" in the production program so that the loop closes within 30
devices.
第 75 页
------------------------------
Code: 1101C07F
Display:
Used by:
Cause: There are over 30 next devices and the loop does not close. This error applies to device numbers
301 to 500.
Remedy: Change the settings in "Next" in the production program so that the loop closes within 30
devices.
------------------------------
Code: 1101C080
Display:
Used by: IP3
Cause: The next device station is not the same as that of the original device. The original device is
between device number 1 and 50.
Remedy: Specify the correct device number in "Next" in the production program's D_data.
------------------------------
Code: 1101C081
Display:
Used by:
Cause: The next device station is not the same as that of the original device. The original device is
between device number 51 and 100.
Remedy: Specify the correct device number in "Next" in the production program's D_data.
------------------------------
Code: 1101C082
Display:
Used by:
Cause: The next device station is not the same as that of the original device. The original device is
between device nunber 101 and 300.
Remedy: Specify the correct device number in "Next" in the production program's D_data.
------------------------------
Code: 1101C083
Display:
Used by:
Cause: The next device station is not the same as that of the original device. The original device is
between device number 301 and 500.
Remedy: Specify the correct device number in "Next" in the production program's D_data.
------------------------------
Code: 1101C084
Display: Same as code
Used by: GP551,GP6
Cause: A speed has been set in the final cleaning sequence.
Remedy: Be sure to set a "-1" for the final cleaning sequence.
------------------------------
Code: 1101C085
Display: Same as code
Used by: GP551,GP6
Cause: Sequence error. Verify that the sequence groups are in the order shown below.
Remedy: Re-arrange the sequences so that the groups are in the proper order,then transfer the data. The
sequence order does not apply within the same group.
Group 1: Mask mark, board fiducial mark sequence
Group 2: Inspection reference sequence
第 76 页
Group 3: Printing sequence
Group 4: Snap-off, cleaning, inspection sequence
------------------------------
Code: 1101C1??
Display:
Used by: CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Same as code (1101C100 + i/20) where i is the sequence number.
Remedy: The sequence references a device number 0 or less or greater than 140.
The device number that has been specified in sequence data is out of range
------------------------------
Code: 1101C2??
Display:
Used by: CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Same as code (1101C200 + i/20) where i is the sequence number.
Remedy: The placing sequence's X data is out of the machine's range of movement.
There is a sequence where the X coordinate is outside the limits of the board in the X direction (PCB_X)
(single board production program).
------------------------------
Code: 1101C3??
Display:
Used by: CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Same as code (1101C300 + i/20) where i is the sequence number.
Remedy: The placing sequence's Y data is out of the machine's range of movement.
------------------------------
Code: 1101C400
Display: 1101C400
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: There is an illegal combination of sequences in the production program.
Remedy: A production program must include two board fiducial sequences, two mask fiducial sequences
and two printing sequences. Check the production program sequences. As an exception it is possible to
transmit a program which contains only printing sequences.
------------------------------
Code: 1101C401
Display: 错误编码的编号无变动
Used by: GSP5,GP551,GP6,GPX
Cause: 生产程序中指定的印刷sequence超出规定范围。
Remedy: 请检查生产程序中的印刷sequence以及Proper的139.Max Limit Position S Holder, 140.Min Limit
Position S Holder。
印刷可设置范围:
(GPX V5.40以上)
·第1个sequence:-15.00mm~电路板尺寸Y
当第1个sequence的起点在电路板外围时
请将第二个sequence的起点设置为0.00mm;剩余印刷区域请从第3个sequence开始依次进行设置。
如果第1个sequence的印刷范围是0.01mm~电路板尺寸Y,
则请将之后的sequence都设置为上一个sequence的终点~电路板尺寸Y。
·最后一个sequence:电路板尺寸Y~电路板尺寸Y+15.00mm
最后一个sequence需要印刷电路板外围时
最后第2个sequence的数值与电路板尺寸Y必须保持一致。
(GPX V5.30以前)
·第1个sequence:1mm~电路板尺寸Y
·第2~第9个sequence:上一个sequence的终点~电路板尺寸Y
第 77 页