FUJI错误代码查询.pdf - 第826页

(value replacing "?" is module number; error code appears in place of asterisks) Remedy: Either return the current tray to the magazine using the [POSITION] command or remove the tray manually. ----------------…

100%1 / 5282
------------------------------
Code: 1207E?3D
Display: "ICM (PMC?, SCU?) Error Code:********" (QP2)
"Instruction to LLL failed" (QP2)
Used by: QP242
Cause: Instruction to LLL failed. ? is the module number. "****" is the error code.
Remedy: Change the LLL board.
------------------------------
Code: 1207E?3E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray not at retract pos." (QP2)
Used by: QP242
Cause: The TZ-axis has attempted to move but the prerequisite conditions are not being satisfied.
SCU I/O: X03D or X03E is ON, X017 is ON
MTU7: When X03D is ON, X01D is ON
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether or not the shuttle's extended position or the retract position sensor is ON. Check
that the tray storage confirmation sensor (tray's expulsion sensor) is not being blocked. If the shuttle is at
the extended position on a MTU-7, check that the TZ-axis interlock sensor is not being blocked.
------------------------------
Code: 1207E?3F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"TZ axis not at org. pos." (QP2)
Used by: QP242
Cause: The TY-axis has attempted to move but the prerequisite conditions are not being satisfied.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check that the TY-axis movement sensor is not being blocked.
(SCU I/O: X03F TY MOVE OK POS... ON)
------------------------------
Code: 1207E?40
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Empty tray container full" (QP2)
Used by: QP242
Cause: Either the MTU-7's empty tray container is full or the tray eject sensor is being blocked.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove the trays from the empty tray container or remove what is blocking the tray eject sensor.
------------------------------
Code: 1207E?41
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray D No. unknown" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Currently not supported. If this error occurs, please contact Fuji.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy:
------------------------------
Code: 1207E?42
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray collect not possible" (QP2)
Used by: QP242
Cause: The tray cannot be returned to the MTU-6 magazine because the tray's device number is
unknown.
第 825 页
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Either return the current tray to the magazine using the [POSITION] command or remove the
tray manually.
------------------------------
Code: 1207E?43
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray positioning sensor NG" (QP2)
Used by: QP242
Cause: The tray height positioning sensor for the tray that has been pulled has been executed but the
sensor will not turn ON or the sensor is already ON.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the state of the tray height positioning sensor.
------------------------------
Code: 1207E?44
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"X-axis measurement command error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The LLL board may be carrying out another command. ? is the module number. "****" is the
error code.(QP2)
X-axis measurement command error.The LLL board may be carrying out another
command.(NP2,QP3)
Remedy: Reboot the machine and retry the operation.
------------------------------
Code: 1207E?45
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"X-axis measurement command processing error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP201,NP2,QP3
Cause: A command was issued to the LLL incorrectly. Or the LLL did not respond correctly. ? is the
module number. "****" is the error code.(QP2)
X-axis measurement command processing error. A command was issued to the LLL incorrectly. Or
the LLL did not respond correctly.(NP2,QP3)
Remedy: Check that the LLL board and the LLL sensor are connected correctly.(QP2,NP2,QP3)
------------------------------
Code: 1207E?46
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Y-axis measurement command error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP201,NP2,QP3
Cause: The LLL board may be carrying out another command. ? is the module number. "****" is the
error code.(QP2)
Y-axis measurement command error. The LLL board may be carrying out another
command.(NP2,QP3)
Remedy: Reboot the machine and retry the operation.
------------------------------
Code: 1207E?47
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Y-axis measurement command processing error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
第 826 页
Cause: A command was issued to the LLL incorrectly. Or the LLL did not respond correctly. ? is the
module number. "****" is the error code.(QP2)
Y-axis measurement command processing error.A command was issued to the LLL incorrectly. Or
the LLL did not respond correctly.(NP2,QP3)
Remedy: Check that the LLL board and the LLL sensor are connected correctly.
------------------------------
Code: 1207E?48
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Measurement completion command error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Another command may currently be executing. ? is the module number. "****" is the error
code.(QP2)
Y-axis measurement command processing error.Another command may currently be
executing.(NP2,QP3)
Remedy: Reboot the machine and retry the operation.
------------------------------
Code: 1207E?4A
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Time out for movement of the TY-axis" (QP2)
Used by: QP242,QP201,QP202,QP203,QP203
Cause: The TY-axis was not positioned within the time limit. ? is the module number. "****" is the error
code.
Remedy: Check that nothing is interfering with the movement of the TY-axis. Also, check there are no
alarms being issued from the control box of the MTU.
------------------------------
Code: 1207E?4B
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Time out for movement of the TZ-axis" (QP2)
Used by: QP242,QP201,QP202,QP203,QP203
Cause: The TZ-axis was not positioned within the time limit. ? is the module number. "****" is the error
code.
Remedy: Check that nothing is interfering with the movement of the TZ-axis. Also, check there are no
alarms being issued from the control box of the MTU.
------------------------------
Code: 1207E?4C
Display: "ICM (PMC?, SCU?) Error Code:********" (QP2)
"MFU/MTU connection error" (QP2)
Used by: QP242
Cause: The MFU/MTU is not connected to the machine. ? is the module number. "****" is the error
code.
Remedy: Connect the MFU/MTU to the machine.
------------------------------
Code: 1207E?4D
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"TZ-axis interlock alarm" (QP2)
Used by: QP242
Cause: The TZ-axis is interlocked. ? is the module number. "****" is the error code.
Remedy: Move the TZ-axis out of interlock using inching.
------------------------------
Code: 1207E?4E
第 827 页