FUJI错误代码查询.pdf - 第521页
------------------------------ Code: 1205200C Display: "Cycle alarm: servo LT" (IP) Used by: IP1 Cause: A cycle alarm has occurred for servo axis LT.The servo axis did not reach the targeted value within the ex…
between the rotor and the nozzle.
------------------------------
Code: 12052006
Display: "R REACH ERR" (CP), "CHECK R-AXIS" (CP3)
Used by: CP3
Cause: A cycle alarm has occurred for servo axis R. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects. On the CP3, check the meshing
between the rotor and the nozzle.
------------------------------
Code: 12052007
Display: "D REACH ERR" (CP), "CHECK D-AXIS" (CP3)
Used by: CP3,CP4-1,CP4-2
Cause: A cycle alarm has occurred for servo axis D. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052008
Display: "C REACH ERR" (CP)
Used by:
Cause: A cycle alarm has occurred for servo axis C. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052009
Display: "Cycle alarm: servo Z(Z1)" (IP), "Cycle alarm Z: Reach" (CP6)
Used by: CP4-1,CP4-2,CP4-
3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,GSP5,GP2,GP3,GP551,GP6,IP1,IP3
Cause: A cycle alarm has occurred for servo axis C. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 1205200A
Display: "Cycle alarm: servo SX" (IP)
Used by: IP1
Cause: A cycle alarm has occurred for servo axis SX.The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 1205200B
Display: "Cycle alarm: servo SY" (IP)
Used by: IP1
Cause: A cycle alarm has occurred for servo axis SY.The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
第 520 页
------------------------------
Code: 1205200C
Display: "Cycle alarm: servo LT" (IP)
Used by: IP1
Cause: A cycle alarm has occurred for servo axis LT.The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 1205200D
Display: "Cycle alarm: servo RT" (IP)
Used by: IP1
Cause: A cycle alarm has occurred for servo axis RT.The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 1205200E
Display: "Cycle alarm: servo X2"
Used by: IP2,IP3
Cause: A cycle alarm has occurred for servo axis X2.The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 1205200F
Display: "Cycle alarm: servo Q2"
Used by: IP2
Cause: A cycle alarm has occurred for servo axis Q2.The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052010
Display: "Cycle alarm: servo Z2" (IP2)
Used by: GL5,GL541,GSP5,GP551,IP2
Cause: A cycle alarm has occurred for servo axis Z2.The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052011
Display: "Cycle alarm: servo S" (GSP)
Used by: GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6
Cause: A cycle alarm has occurred for servo axis S. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052012
Display: "Cycle alarm: servo ZL" (GL)
第 521 页
Used by: GL2
Cause: A cycle alarm has occurred for servo axis ZL.The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052013
Display: "Cycle alarm: servo ZR" (GL)
Used by: GL2
Cause: A cycle alarm has occurred for servo axis ZR.The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052014
Display: "Cycle alarm: servo Z3" (GL5)
Used by: GL5,GL541
Cause: A cycle alarm has occurred for servo axis Z3.The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052015
Display: PQ Rotation Alarm
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The pre-theta could not be rotated within the cycle time.
Remedy: Check that the axis is not overloaded. Remove any objects that interfere with axis
movement.Check the cylinder's advance and retract sensors.
------------------------------
Code: 12052016
Display: "Servo cycle alarm FQ" (CP4), "Cycle alarm <R> FQ: Reach" (CP6)
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: On the CP4, [fine sheeter] rotation could not be completed within the cycle time.On the CP6, FQ-
axis rotation could not be completed within the cycle time; if an <R> is displayed, the FQ-axis was being
returned (10ST).
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052017
Display: Cycle Alarm Search Error
Used by:
Cause: The pre-theta origin point cannot be found.
Remedy: Check the station 2 position sensor.
------------------------------
Code: 12052018
Display: 4st clutch NG
Used by:
Cause: The clutch did not engage at station 4.
Remedy: Check that there are no alarms at the station 4 clutch and the nozzle shaft.
------------------------------
Code: 12052019
第 522 页