FUJI错误代码查询.pdf - 第1382页
Code: 1D0DE??? Display: Used by: Cause: The image in vision processing is not correct so operation was canceled. Remedy: Check the part. Check the direction of part supply. Cheak the entries in Part data and Device data.…
Remedy: Check the part. Check the direction of part supply. Cheak the entries in Part data and Device
data.
------------------------------
Code: 1D0DC3??
Display:
Used by:
Cause: A lead could not be detected on the upper side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Cheak the entries in Part data and Device
data.
------------------------------
Code: 1D0DC4??
Display:
Used by:
Cause: An edge could not be detected on the left side of the part.
Remedy: Check the part. Check the direction of part supply. Cheak the entries in Part data and Device
data.
------------------------------
Code: 1D0DC5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Cheak the entries in Part data and Device
data.
------------------------------
Code: 1D0DC6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Cheak the entries in Part data and Device
data.
------------------------------
Code: 1D0DC7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Cheak the entries in Part data and Device
data.
------------------------------
Code: 1D0DD000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D0DD080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
第 1381 页
Code: 1D0DE???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Cheak the entries in Part data and Device
data.
------------------------------
Code: 1D0DF???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D0E0002
Display:
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D0E0010
Display:
Used by:
Cause: An edge without leads was not found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0011
Display:
Used by:
Cause: An edge without leads was not found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0012
Display:
Used by:
Cause: The lead length was too short (less than 90% of the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0013
Display:
Used by:
Cause: The lead length was too long (over 10% longer than the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0014
Display:
Used by:
Cause: The lead length was too short (less than 90% of the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0015
Display:
第 1382 页
Used by:
Cause: The lead length was too long (over 10% longer than the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0016
Display:
Used by:
Cause: The lead length was too short (less than 90% of the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0017
Display:
Used by:
Cause: The lead length was too long (over 10% longer than the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0018
Display:
Used by:
Cause: The lead length was too short (less than 90% of the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0019
Display:
Used by:
Cause: The lead length was too long (over 10% longer than the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E001A
Display:
Used by:
Cause: The part shape is not what was expected. Vision processing cannot take a good image.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E001B
Display:
Used by:
Cause: There are too many leads (set in PDG).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E001C
Display:
Used by:
Cause: There are too many leads (set in PDG).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0020
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
第 1383 页