FUJI错误代码查询.pdf - 第181页

Remedy: Check the Recovery_count setting in Status data. ------------------------------ Code: 11032002 Display: Used by: GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,IP1,IP3 Cause: Status data's Production_report …

100%1 / 5282
Cause: The maximum pulse count for movement of the PMC X-axis in the minus direction was not
specified.
Remedy: Specify 1058 + offset. Min Limit Position X in Proper data, where offset = (PMC No. - 1)*50)
------------------------------
Code: 11025?14
Display: Same as Code.
Used by: QP132
Cause: The PMC's Y-axis extended position is not set.
Remedy: Set the Proper data item "Max Limit Position Y" to the correct value. This Proper data item exists
for each module. Module one is number 729 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?15
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?16
Display: Data Check Error [11025?16]
Used by: QP132
Cause: The camera center for the AB nozzle and the E nozzle is not set.
Remedy: Perform the Proper data measurement of AB and E nozzles' camera center or check Proper data
items 276?467.
------------------------------
Code: 11025?17
Display: Data Check Error [11025?17]
Used by: QP132
Cause: The camera center for the CD nozzle and the F nozzle is not set.
Remedy: Perform the Proper data measurement of CD and F nozzles' camera center or check Proper data
items 276?467.
------------------------------
Code: 11025?18
Display: Data Check Error [11025?18]
Used by: QP132
Cause: The value for the lean tolerance item is out of range.
"?" indicates the module number in hexadecimal notation. "0" indicates PMC 16.
Remedy: The lean tolerance range for a PMC is -50 to +50 1/1000 deg.
Set the Proper data item "739. Lean offset" (PMC 1) to a value in the range. For other Proper data
numbers (module number - 1) x 82.
------------------------------
Code: 11032000
Display:
Used by: GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,IP1,IP3
Cause: Status data's Error setting is out of range.
Remedy: Check the Error setting in Status data.
------------------------------
Code: 11032001
Display:
Used by: IP1
Cause: Status data's Recovery_count setting is out of range.
第 180 页
Remedy: Check the Recovery_count setting in Status data.
------------------------------
Code: 11032002
Display:
Used by: GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,IP1,IP3
Cause: Status data's Production_report setting is out of range.
Remedy: Check the Production_report setting in Status data.
------------------------------
Code: 11032003
Display: 11032003
Used by: GSP5,GP551,GP6
Cause: The error setting in status data is inappropriate.
Remedy: Check the error setting in status data. Auto_recovery cannot be used on the GSP series.
Therefore, enable Error_stop or Error_pass and retransmit the status data to the machine.
------------------------------
Code: 11050001
Display: Program Check NG
Pallet ID is not specified (FCP651C)
Used by: CP652C
Cause: The ID of the pallet to be used in production has not been specified.
Remedy: Use the [PROGRAM] -> [DEVICE] -> [PALLET ID] command sequence at the machine to specify
the pallet ID. Edit the pallet ID table, then retransmit (FCP651C).
------------------------------
Code: 11050002
Display: 11050002
Used by: CP652C
Cause: Overlapping pallet ID numbers have been set in the pallet ID table.
Remedy: Edit the pallet ID table, then retransmit.
------------------------------
Code: 11060001
Display:
Used by:
Cause: The specified module number is less than 1
Remedy: None.
------------------------------
Code: 11060002
Display:
Used by:
Cause: The specified module number has not been transmitted.
Remedy: None.
------------------------------
Code: 11060003
Display:
Used by:
Cause: There is no empty module block
Remedy: Delete programs 1~9 at the machine.
------------------------------
Code: 11060004
Display:
Used by:
Cause: There is no empty data area
第 181 页
Remedy: Delete programs 1~9 at the machine.
------------------------------
Code: 11060005
Display:
Used by:
Cause: Syntax error. An unregistered command has been sent to the machine.
Remedy: Press the [Reset] button. Reboot MCS.
------------------------------
Code: 11060006
Display:
Used by:
Cause: There is no data name.
Remedy: None.
------------------------------
Code: 11060007
Display:
Used by:
Cause: There was a program with the same data name used previously.
Remedy: None.
------------------------------
Code: 11060008
Display:
Used by:
Cause: The program was transmitted prior to the DVH.
Remedy: Re-transmit the program.
------------------------------
Code: 11060009
Display:
Used by:
Cause: The program was transmitted prior to the DQ.
Remedy: None.
------------------------------
Code: 1106000A
Display:
Used by:
Cause: The initialize non-permission flag setting is finished.
Remedy: None.
------------------------------
Code: 1106000B
Display:
Used by:
Cause: The specified address is outside the data perimeters.
Remedy: None.
------------------------------
Code: 1106000C
Display:
Used by:
Cause: The specified ID was not transmitted.
Remedy: None.
------------------------------
Code: 1106000D
第 182 页