FUJI错误代码查询.pdf - 第562页

retract position sensor (X07B). Check the input status of the out-setup station pallet pass-through sensor (X06F). Check the input status of the out-setup station pallet sensor (X07F). Check the input status of the out-p…

100%1 / 5282
Used by: CP652C
Cause: When the pallet is moving from the in-setup station to the in-position:
1. The in-setup station cylinder has not reached its extended position in the 10 seconds allowed.
2. The input status for each of the sensors, after the in-setup station cylinder has arrived at its extended
position, is as follows:
- The retract position (extended position) sensor is on.
- The in-setup station pallet pass-through sensor (between in-position <-> in-setup station) is detecting a
pallet.
- The in-setup station pallet sensor is detecting a pallet.
- The in-position pallet sensor is not detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X072) for the in-setup station cylinder and the
retract position sensor (X073).
Check the input status of the in-setup station pallet pass-through sensor (X06E).
Check the input status of the in-setup station pallet sensor (X077).
Check the input status of the in-position pallet sensor (X046).
------------------------------
Code: 12054089
Display: "Pallet Transport ERROR IN Pos -> SETUP_ST. IN."
Used by: CP652C
Cause: When the pallet is moving from the in-position to the in-setup station:
1. The in-setup station cylinder has not reached its retract position in the 10 seconds allowed.
2. The input status for each of the sensors, after the in-setup station cylinder has arrived at its retract
position, is as follows:
- The extended position sensor is on.
- The in-setup station pallet pass-through sensor (between in-position <-> in-setup station) is not
detecting a pallet.
- The in-setup station pallet sensor is not detecting a pallet.
- The in-position pallet sensor is detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X072) for in-setup station cylinder and the retract
position sensor (X073).
Check the input status of the in-setup station pallet pass-through sensor (X06E).
Check the input status of the in-setup station pallet sensor (X077).
Check the input status of the in-position pallet sensor (X046).
------------------------------
Code: 1205408A
Display: "Pallet Transport ERROR SETUP_ST. OUT -> OUT Pos."
Used by: CP652C
Cause: A pallet transport error occured between the out-setup station and the out-position.
When the pallet is moving from the out-setup station to the out-position:
1. The out-setup station cylinder has not reached its extended position in the 10 seconds allowed.
2. The input status for each of the sensors, after the out-setup station cylinder has arrived at its extended
position, is as follows:
- The retract position sensor is on.
- The out-setup station pallet pass-through sensor (between out-position <-> out-setup station) is
detecting a pallet.
- The out-setup station pallet sensor is detecting a pallet.
- The out-position pallet sensor is not detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X07A) for the out-setup station cylinder and the
第 561 页
retract position sensor (X07B).
Check the input status of the out-setup station pallet pass-through sensor (X06F).
Check the input status of the out-setup station pallet sensor (X07F).
Check the input status of the out-position pallet sensor (X047).
------------------------------
Code: 1205408B
Display: "Pallet Transport ERROR OUT Pos. -> SETUP_ST. OUT"
Used by: CP652C
Cause: A pallet transport error occured between the out-setup station and the out-position.
When the pallet is moving from the out-position to the out-setup station:
1. The out-setup station cylinder has not reached its retract position in the 10 seconds allowed.
2. The input status for each of the sensors, after the out-setup station cylinder has arrived at its retract
position, is as follows:
- The extended position sensor is on.
- The out-setup station pallet pass-through sensor (between out-position <-> out-setup station) is not
detecting a pallet.
- The out-setup station pallet sensor is not detecting a pallet.
- The out-position pallet sensor is detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X07A) for the out-setup station cylinder and the
retract position sensor (X07B).
Check the input status of the out-setup station pallet pass-through sensor (X06F).
Check the input status of the out-setup station pallet sensor (X07F).
Check the input status of the out-position pallet sensor (X047).
------------------------------
Code: 1205408C
Display: "Pallet Transport ERROR R. Conveyor -> Filler"
Used by: CP652C
Cause: A pallet transport error occurs when the PPS filler is operating.
1. The return-conveyor out cylinder has not reached it extended position in the 10 seconds allowed.
2. The input status for each of the sensors, after the return-conveyor out cylinder has reached its
extended position, is as follows:
- The cylinder retract position sensor is on.
- The filler pallet sensor is not detecting a pallet.
- The return-conveyor pallet arrival sensor is detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X09A) for the return-conveyor out cylinder and
the retract position sensor (X09B).
Check the input status of the filler pallet sensor (X094).
Check the input status of the return-conveyor pallet arrival sensor (X09E).
------------------------------
Code: 1205408D
Display: "Pallet Transport ERROR Filler -> PPS"
Used by: CP652C
Cause: A pallet transport error occurred between the filler and the PPS6.
1. After the PPS6 has pulled the pallet in (after the cylinder on the lower conveyor has reached its
extended position), the filler pallet sensor is still detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the PPS6 lower conveyor cylinder's extended position and retract position.
Check the input status of the filler pallet sensor (X094).
------------------------------
第 562 页
Code: 1205408E
Display: "SETUP_ST. IN Feeder Time Out"
Used by: CP652C
Cause: The cylinder used to clamp the pallet, when clamping is attempted by the in-setup station
cylinder, has not reached the clamp position in the 10 seconds allowed.
Remedy: Check that there is nothing obstructing the movement of the in-setup station cylinder.
Check the input status of the extended (X072) and retract (X073) position for the in-setup station cylinder.
------------------------------
Code: 1205408F
Display: "SETUP_ST. IN Slide Time Out"
Used by: CP652C
Cause: Operation of the in-setup station slide has not been completed in the 10 seconds allowed.
Remedy: Check that there is nothing obstructing the movement of the in-setup station slide.
Check the input status of the extended (X070) and retract (X071) position for the in-setup station slide.
------------------------------
Code: 12054090
Display: "SETUP_ST. OUT Feeder Time Out"
Used by: CP652C
Cause: The cylinder used to clamp the pallet, when clamping is attempted by the out-setup station
cylinder, has not reached the clamp position in the 10 seconds allowed.
Remedy: Check that there is nothing obstructing the movement of the out-setup station cylinder.
Check the input status of the extended (X07A) and retract (X07B) position for the out-setup station
cylinder.
------------------------------
Code: 12054091
Display: "SETUP_ST. OUT Slide Time Out"
Used by: CP652C
Cause: Operation of the out-setup station slide has not been completed in the 10 seconds allowed.
Remedy: Check that there is nothing obstructing the movement of the out-setup station slide.
Check the input status of the extended (X078) and retract (X079) position for the out-setup station slide.
------------------------------
Code: 12054092
Display: "SETUP_ST. IN Interlock on"
Used by: CP652C
Cause: The pallet pass-through sensor between the in-setup station and in-position is detecting a pallet
as the in-setup station slide attempts to move.
Remedy: Remove the obstruction.
Check the pallet pass-through sensor (X06E).
------------------------------
Code: 12054093
Display: "SETUP_ST. OUT Interlock on"
Used by: CP652C
Cause: The pallet pass-through sensor between the out-setup station and out-position is decting a pallet
as the out-setup station slide attempts to move.
Remedy: Remove the obstruction.
Check the pallet pass-through sensor (X06F).
------------------------------
Code: 12054094
Display: "SETUP_ST. IN Origin Position Error"
Used by: CP652C
Cause: The slide is off-center of the extended position when the pallet attempts to move between the in-
第 563 页