FUJI错误代码查询.pdf - 第432页
Cause: Axis number 1 deviation overflow. Remedy: Turn off the machine power. ------------------------------ Code: 12035105 Display: Used by: CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132 Cause: Axis number 1 + soft limit. Remed…
Code: 12034202
Display:
Used by:
Cause: The remote I/O board circuit is not ready.
Remedy: Check the cable or the programmable controller.
------------------------------
Code: 12034204
Display:
Used by:
Cause: The OP link is not ready.
Remedy: Check the cable or the programmable controller.
------------------------------
Code: 12034208
Display:
Used by:
Cause: Remote I/O alarm.
Remedy: None.
------------------------------
Code: 12034210
Display:
Used by:
Cause: An interrupt was not received from the remote I/O board.
Remedy: Check the mother board interrupt jumper.
------------------------------
Code: 12034220
Display:
Used by: None.
Cause: Failed in remote I/O board (2nd board) initialization.
Remedy: Reboot the machine.
------------------------------
Code: 12035101
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 1 system error.
Remedy: Turn off the machine power.
------------------------------
Code: 12035102
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 1 incorrect command.
Remedy: Turn off the machine power.
------------------------------
Code: 12035103
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 1 placement time too long.
Remedy: Turn off the machine power.
------------------------------
Code: 12035104
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
第 431 页
Cause: Axis number 1 deviation overflow.
Remedy: Turn off the machine power.
------------------------------
Code: 12035105
Display:
Used by: CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 1 + soft limit.
Remedy: Turn off the machine power.
------------------------------
Code: 12035106
Display:
Used by: CP6,CP6M,CP65,GP551,GP6,QP132
Cause: Axis number 1 - soft limit.
Remedy: Turn off the machine power.
------------------------------
Code: 12035107
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 1 not ready.
Remedy: Turn off the machine power.
------------------------------
Code: 12035108
Display:
Used by: CP5,CP6,CP6M,CP65,QP132
Cause: Axis number 1 emergency stop.
Remedy: Turn off the machine power.
------------------------------
Code: 12035109
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Incorrect parameter was sent from axis number 1.
Remedy: Turn off the machine power.
------------------------------
Code: 1203510A
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132,NP133E,NP134E,NP153E
Cause: Axis number 1 encoder error.
Remedy: Turn off the machine power.
------------------------------
Code: 1203510B
Display:
Used by: CP5,CP6,CP6M,CP65
Cause: Axis number 1 synchronicity error.
Remedy: Cut the machine power.
------------------------------
Code: 1203510C
Display:
Used by: CP5,CP6,CP6M,CP65,GP551,GP6
Cause: The servo interlock was activated during startup.
Remedy: Check the interlock sensor.
------------------------------
第 432 页
Code: 12035201
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 2 system error.
Remedy: Turn off the machine power.
------------------------------
Code: 12035202
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 2 incorrect command.
Remedy: Turn off the machine power.
------------------------------
Code: 12035203
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 2 placement time too long.
Remedy: Turn off the machine power.
------------------------------
Code: 12035204
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 2 deviation overflow.
Remedy: Turn off the machine power.
------------------------------
Code: 12035205
Display:
Used by: CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 2 + soft limit.
Remedy: Turn off the machine power.
------------------------------
Code: 12035206
Display:
Used by: CP6,CP6M,CP65,GP551,GP6,QP132
Cause: Axis number 2 - soft limit.
Remedy: Turn off the machine power.
------------------------------
Code: 12035207
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 2 not ready.
Remedy: Turn off the machine power.
------------------------------
Code: 12035208
Display:
Used by: CP5,CP6,CP6M,CP65,QP132
Cause: Axis number 2 emergency stop.
Remedy: Turn off the machine power.
------------------------------
Code: 12035209
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
第 433 页