FUJI错误代码查询.pdf - 第2277页

occur. Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","DEVICE+"in the production program. ------------------------------ Code: 52??1073 Display: "GUTNSSLT"va…

100%1 / 5282
------------------------------
Code: 52??1060
Display: "GUTNDN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTNDN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line.
------------------------------
Code: 52??1061
Display: "GUTPDN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTPDN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line. "GUTPDN" is a mandatory item.
------------------------------
Code: 52??1062
Display: Part data name for "GUTPDN" is too long.
Used by:
Cause: "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" data in the specified production program was read
and the "GUTPDN" part data name was too long. The file name is abbreviated to its maximum length
when downloaded.
Remedy: Check the "GUTPDN" setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line.
------------------------------
Code: 52??1070
Display: "GSQSSLTN"value out of range.
Used by:
Cause: An out of range value was detected for"GSQSSLTN"in the"BLOCK","SEQUENCE+"data
when"UNIT","PROGRAM"in the specified production program was read.
Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","SEQENCE+"in the production program.
Normally the sequence number in which the error occurred is reported to the supplementary information
line. Check this line.
------------------------------
Code: 52??1071
Display: No"GUTSSLTN"item declaration.
Used by:
Cause: No"GUTSSLTN"entry was found in the item declaration line
in"BLOCK","DEVICE+"when"UNIT","PROGRAM"in the specified production program was read.
Remedy: Check the"GUTSSLTN"setting in the item declaration line in"UNIT","PROGRAM"-
"BLOCK","DEVICE+"in the production program. "GUTSSLTN"is a mandatory item.
------------------------------
Code: 52??1072
Display: "GUTSSLTN"value out of range.
Used by:
Cause: An out of range value was detected for"GUTSSLTN"in the"BLOCK","DEVICE+"data
when"UNIT","PROGRAM"in the specified production program was read. At present this error does not
第 2276 页
occur.
Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","DEVICE+"in the production program.
------------------------------
Code: 52??1073
Display: "GUTNSSLT"value out of range.
Used by:
Cause: An out of range value was detected for"GUTSSLTN"in the"BLOCK","DEVICE+"data
when"UNIT","PROGRAM"in the specified production program was read.
Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","DEVICE+"in the production program.
Generally the stage number,slot number,sub slot number in which the error occurred is reported to the
supplementary information line.
------------------------------
Code: 52??1074
Display: Invalid combination of sub slot numbers found.
Used by:
Cause: Both a zero and a non-zero value exist for the same slot of the same stage in the specified
program.
Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","DEVICE+"or"UNIT","PROGRAM"-
"BLOCK","SEQUENCE+"in the production program. Generally the sequence number at which the error
occurred is reported to the supplementary information line if the problem was found in
the"SEQUENCE+"section. If the problem lies in the "DEVICE+"section,the stage number,slot number and
sub slot number in which the error occurred is generally reported to the supplementary information line.
------------------------------
Code: 52??1100
Display: Unused sequence data.
Used by:
Cause: In "BLOCK", "SEQUENCE+" in "UNIT", "PROGRAM" in the specified production program, there are
sequence lines with "GSQSN" values (the sequence numbers) which exceed the specified "GSMSQQ" value
(the number of sequences in the program).
Remedy: Check the data settings for "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the specified
production program. Furthermore, check that the setting for "GSQSMM" in "UNIT", "PROGRAM" -
"BLOCK", "PGHEAD-" is correct.
------------------------------
Code: 52??1101
Display: Out of range sequence data.
Used by:
Cause: In "BLOCK", "SEQUENCE+" in "UNIT", "PROGRAM" there are sequence lines with "GSQSN" values
which are invalid for the applicable machine type.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the production
program.
------------------------------
Code: 52??1102
Display: Multiply defined sequence data.
Used by:
Cause: An attempt was made to read a sequence number in "BLOCK", "SEQUENCE+" in "UNIT",
"PROGRAM" in the production program but the data line for this sequence number was multiply defined.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the production
program.
------------------------------
Code: 52??1110
Display: Unused device data.
第 2277 页
Used by:
Cause: In "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the specified production program, the reported
device line is not referred to in "BLOCK", "SEQUENCE+".
Remedy: Check the data setting in "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the production
program. Also check the data setting in "UNIT", "PROGRAM" - "BLOCK", "DEVICE+".
------------------------------
Code: 52??1111
Display: Out of range device data.
Used by:
Cause: In "BLOCK", "DEVICE+" in "UNIT", "PROGRAM" there are device lines with "GUTSTN", "GUTSLTN"
values or "GUTDN" values which are invalid for the applicable machine type.
Remedy: Check the data settings for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program.
------------------------------
Code: 52??1112
Display: Multiply defined device data.
Used by:
Cause: In "BLOCK", "DEVICE+" in "UNIT", "PROGRAM" the data lines for the reported device are multiply
defined.
Remedy: Check the data settings for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program.
------------------------------
Code: 52??1120
Display: The"GSQGSS"value is out of range.
Used by:
Cause: The value for item"GSQGSS"has been detected as out of range at the data reading of
"BLOCK","SEQUENCE+"when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the data settings under"BLOCK","SEQUENCE+"of"UNIT","PROGRAM". Since the sequence
number where the error occurs is generally recorded in supplemental data,check the corresponding
sequence data line.
------------------------------
Code: 52??1121
Display: The data values for the item"GSQGSS"are the same for the lines where the item"GSQST"are set
to'S'and'E'.
Used by:
Cause: In the lines where'S'and'E'are set for the item"GSQST",the values set,in the
corresponding"GSQGSS"item,are the same. This was determined at the data reading
of"BLOCK","SEQUENCE+"when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the data settings under"BLOCK","SEQUENCE+"of"UNIT","PROGRAM". The value for
item"GSQGSS",of the line where item"GSQST"is set to'S',cannot be the same as the value for
the"GSQGSS"item of the line where item"GSQST"is set to'E'.If the values for item"GSQST"are the same,no
error occurs even if more than one line containing the same value for item"GSQGSS"exists.Since the
sequence number where the error occurs is generally recorded in supplemental data,check the
corresponding sequence data line as well as the lines before it.
------------------------------
Code: 52??1122
Display: Too many"GSQGSS"entries.
Used by:
Cause: There are too many lines which are set to'S'and'E'in item"GSQST". This was determined at the
data reading of"BLOCK","SEQUENCE+"when"UNIT","PROGRAM"of the specified production program was
read.
第 2278 页