Used by: Cause: MCS/2 programs used on XP-141E with the Program Polarity setting set to "No" cannot be used on other machine types. Remedy: Set the Program Polarity setting to "Yes". -----------------…
Code: 2300E11C
Display: The main and sub marks are too close together.
Used by:
Cause: Unable to correct placement because the main and sub marks are too close together.
Remedy: Revise the mark settings or to separate the main and sub marks by at least 5 mm.
------------------------------
Code: 2300E11D
Display: Another group skip mark sequence has the same mark number.
Used by:
Cause: Another group skip mark sequence has the same mark number.
Remedy: Change the mark number.
------------------------------
Code: 2300E11E
Display: There is a group skip mark sequence after a board skip mark sequence.
Used by:
Cause: The insertion order is incorrect.There is a group skip mark sequence after a board skip mark
sequence.
Remedy: Change the insert order so that group skip mark sequences are before board skip mark
sequences.
------------------------------
Code: 2300E11F
Display: There is a global skip mark sequence after a group skip or board skip mark sequence.
Used by:
Cause: The insertion order is incorrect.There is a global skip mark sequence after a group skip or board
skip mark sequence.
Remedy: Change the insert order so that global skip sequences are before group skip mark sequences and
board skip mark sequences.
------------------------------
Code: 2300E120
Display: To reference a fiducial mark,a fiducial mark whose board number 0 is required.
Used by:
Cause: When referencing a fiducial mark for a global skip mark,group skip mark,or board skip mark,a
fiducial mark whose board number is 0 is required.
Remedy: Create a fiducial mark sequence whose board number is 0.
------------------------------
Code: 2300E121
Display: The reference fiducial mark is after the current sequence.
Used by:
Cause: The insertion order is incorrect.The reference fiducial mark is after the current sequence.
Remedy: Change the insert order so that the reference fiducial mark is before the indicated sequence.
------------------------------
Code: 2300E201
Display: The Program polarity item's [No] setting is not supported.
Used by:
Cause: XP-series machines do not support Program Polarity's "No" setting.q宝xcept for program data
transmitted from MCS/2q搽Remedy: Set the Program Polarity setting to "Yes".
Remedy: Set the Program Polarity setting to "Yes".
------------------------------
Code: 2300E202
Display: The Program Polarity setting [No] in the production program which was transmitted from the
MCS/2 to the XP-141E is not supported.
第 2130 页
Used by:
Cause: MCS/2 programs used on XP-141E with the Program Polarity setting set to "No" cannot be used
on other machine types.
Remedy: Set the Program Polarity setting to "Yes".
------------------------------
Code: 2300E203
Display: The Program Polarity setting [No] in the production program which was transmitted from the
MCS/2 to the XP-241E/XP-341E is not supported.
Used by:
Cause: MCS/2 programs used on XP-241E and XP-341E with the Program Polarity setting set to "No"
cannot be used on other machine types.
Remedy: Set the Program Polarity setting to "Yes".
------------------------------
Code: 2300E301
Display: Part number has not been specified.
Used by:
Cause: No part number has been set.
Remedy: Either specify a part number or delete the data.
------------------------------
Code: 2300E302
Display: Part data cannot be found.
Used by:
Cause: Data corresponding to the part number does not exist.
Remedy: Create the specified part number data, or specify an existing part number.
------------------------------
Code: 2300E303
Display: Unset slots are included in the slot loop.
Used by:
Cause: A vacant slot number (no setting data) is set as the "next slot" number.
Remedy: Specify a slot number with a same part number.
------------------------------
Code: 2300E304
Display: The part number does not match that of the Alt. Feeder.
Used by:
Cause: A slot number with a different part number setting has been specified as the "next slot".
Remedy: Specify a slot number with a same part number setting for use as the "next slot".
------------------------------
Code: 2300E305
Display: The Alt. Feeder number must be set to a separate feeder.
Used by:
Cause: The slot number and next slot number are identical.
Remedy: Specify a "next slot" number which is different from the slot number.
------------------------------
Code: 2300E306
Display: The alternate feeder setting is not a loop.
Used by:
Cause: The next slot number does not have a loop structure.
Remedy: Set the next slot number so that a loop structure is created.
------------------------------
Code: 2300E307
Display: The packaging type specified in part data cannot be used on this stage.
第 2131 页
Used by:
Cause: A part number with a Packaging Type of "Tray" is set for a Feeder stage number and slot number,
or, a part number with a Packaging Type other than "Tray" is set for a Tray stage number and slot
number.
Remedy: For Feeder stage numbers and slot numbers, specify a part number with a Packaging Type other
than "Tray". For Tray stage numbers and slot numbers, specify a part number with Packaging Type of
"Tray".
------------------------------
Code: 2300E401
Display: Fiducial Marks have not been set.
Used by:
Cause: There is no fiducial mark setting in the production program.
Remedy: Specify a fiducial mark setting at the Edit Mark screen.
------------------------------
Code: 2300E402
Display: Board skip marks have not been set.
Used by:
Cause: A board skip mark reading sequence exists, but there is no board skip mark setting.
Remedy: Specify a board skip mark setting at the Edit Mark screen.
------------------------------
Code: 2300E501
Display: The Polarity Setting item's [Not Use] setting is not supported.
Used by:
Cause: XP-series machines do not support Polarity Setting's "Not Use" setting.q宝xcept for program data
transmitted from MCS/2q搽Remedy: Set the Polarity Setting to another setting.
Remedy:
------------------------------
Code: 2300E502
Display: The Polarity Setting setting [Not Use] in the production program which was transmitted from the
MCS/2 to the XP-141E is not supported.
Used by:
Cause: MCS/2 programs used on XP-141E with the Polarity Setting set to "Not Use" cannot be used on
other machine types.
Remedy: Set the Polarity Setting to another setting.
------------------------------
Code: 2300E503
Display: The Polarity Setting setting [Not Use] in the production program which was transmitted from the
MCS/2 to the XP-241E/XP-341E is not supported.
Used by:
Cause: MCS/2 programs used on XP-241E and XP-341E with the Polarity Setting set to "Not Use" cannot
be used on other machine types.
Remedy: Set the Polarity Setting to another setting.
------------------------------
Code: 2300E540
Display: No suitable nozzle exists.
Used by:
Cause: The nozzle data contains neither the nozzle specified by the NozzleName item (in Part Type data),
or a nozzle which satisfies the NozzleSizeMin to NozzleSizeMax range setting.
Remedy: Specify the appropriate nozzle in the nozzle data.
------------------------------
Code: 2300E541