Code: 15040326 Display: XY-table unclamping error. Used by: CP-732E, CP-742ME, CP-742E Cause: The XY-table panel clamper's fixed rail side unclamp limit signal for the first panel failed to switch on even though a p…
------------------------------
Code: 15040319
Display: The conveyor width differs from the board width set in the production program.
Used by: NP-133E
Cause: The width of the board (set at "PCB Size Y" in the production program), differs from the width of
the conveyor. Alternatively, the maximum conveyor width (Proper data item "Conveyor Width Limit") may
have been exceeded.
Remedy: Check the settings at the production program item "PCB Size Y" and the Proper data item
"Conveyor Width Limit".
------------------------------
Code: 15040320
Display: XY-table is out of the loading position range.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: XY-table is out of the loading position range.
Remedy: Move the XY-table to the loading position.
------------------------------
Code: 15040321
Display: XY-table clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side clamp limit signal for the first panel failed to switch
on even though a panel clamp command was executed.
Remedy: Verify that the XY-table is clamping the panel correctly.
------------------------------
Code: 15040322
Display: XY-table clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side unclamp limit signal for the first panel failed to
switch off even though a panel clamp command was executed.
Remedy: Verify that the XY-table is clamping the panel correctly.
------------------------------
Code: 15040323
Display: XY-table clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side unclamp limit signal for the second panel failed to
switch off even though a panel clamp command was executed.
Remedy: Verify that the XY-table is clamping the panel correctly.
------------------------------
Code: 15040324
Display: XY-table clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's adjustable rail side clamp limit signal failed to switch on even
though a panel clamp command was executed.
Remedy: Verify that the XY-table is clamping the panel correctly.
------------------------------
Code: 15040325
Display: XY-table clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's adjustable rail side unclamp limit signal failed to switch off even
though a panel clamp command was executed.
Remedy: Verify that the XY-table is clamping the panel correctly.
------------------------------
第 1126 页
Code: 15040326
Display: XY-table unclamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side unclamp limit signal for the first panel failed to
switch on even though a panel unclamp command was executed.
Remedy: Verify that the XY-table is unclamping the panel correctly.
------------------------------
Code: 15040327
Display: XY-table unclamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side clamp limit signal for the first panel failed to switch
off even though a panel unclamp command was executed.
Remedy: Verify that the XY-table is unclamping the panel correctly.
------------------------------
Code: 15040328
Display: XY-table unclamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side unclamp limit signal for the second panel failed to
switch on even though a panel unclamp command was executed.
Remedy: Verify that the XY-table is unclamping the panel correctly.
------------------------------
Code: 15040329
Display: XY-table unclamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side clamp limit signal for the second panel failed to
switch off even though a panel unclamp command was executed.
Remedy: Verify that the XY-table is unclamping the panel correctly.
------------------------------
Code: 1504032A
Display: XY-table unclamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's adjustable rail side unclamp limit signal failed to switch on even
though a panel unclamp command was executed.
Remedy: Verify that the XY-table is unclamping the panel correctly.
------------------------------
Code: 1504032B
Display: XY-table unclamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's adjustable rail side clamp limit signal failed to switch off even
though a panel unclamp command was executed.
Remedy: Verify that the XY-table is unclamping the panel correctly.
------------------------------
Code: 1504032D
Display: XY-table clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side unclamp limit signal for the second panel failed to
switch on even though a panel clamp command was executed.
Remedy: Verify that the XY-table is clamping the panel correctly.
------------------------------
Code: 1504032E
Display: XY-table up/down travel time-up.
第 1127 页
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: XY-table up/down travel was not completed within the prescribed period of time.
Remedy: Check for objects which may be interfering with XY-table up/down travel.
------------------------------
Code: 15040330
Display: XY-table clamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A clamp limit sensor failed to switch on at one of the following:
qd The XY-table's first panel clamper at the fixed-rail side
qd The XY-tables second panel clamper at the fixed-rail side
qd The clamper at the adjustable-rail side
Remedy: Check to see if the panel is clamped properly. If clamped properly but this error occurs anyway,
adjust the mounting position of the clamp limit sensor. If the error still occurs, there may be a sensor
wiring problem or a sensor failure.
------------------------------
Code: 15040331
Display: XY-table unclamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: An unclamp limit sensor was not triggered at one of the following locations:
qd The XY-table's first panel clamper at the fixed-rail side
qd The XY-tables second panel clamper at the fixed-rail side
qd The clamper at the adjustable-rail side
Remedy: Check to see if the panel is clamped properly. If clamped properly but this error occurs anyway,
adjust the mounting position of the unclamp limit sensor. If the error still occurs, there may be a sensor
wiring problem or a sensor failure.
------------------------------
Code: 15040332
Display: XY-table unclamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: An unclamp limit sensor failed to switch on at one of the following locations:
qd The XY-table's first panel clamper at the fixed-rail side
qd The XY-tables second panel clamper at the fixed-rail side
qd The clamper at the adjustable-rail side
Remedy: Check to see if the panel is properly unclamped. If properly unclamped but this error occurs
anyway, adjust the mounting position of the unclamp limit sensor. If the error still occurs, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 15040333
Display: XY-table clamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A clamp limit sensor failed to switch off at one of the following locations:
qd The XY-table's first panel clamper at the fixed-rail side
qd The XY-tables second panel clamper at the fixed-rail side
qd The clamper at the adjustable-rail side
Remedy: Check to see if the panel is properly unclamped. If properly unclamped but this error occurs
anyway, adjust the mounting position of the clamp limit sensor. If the error still occurs, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 15040334
Display: XY-table clamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
第 1128 页