Display: There is a "UNIT", "MARK". Used by: Cause: Even though "UNIT", "MARK" is specified as being separate from the production program, "UNIT", "MARK" exists…
Code: 52??1222
Display: No "UNIT", "MARK" - "BLOCK", "HEADER-".
Used by:
Cause: "BLOCK", "HEADER" was not found in "UNIT", "MARK" in the specified production program. This
report is made if the mark data and production program are in the same file and the above error is
detected.
Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "HEADER" in the specified production
program.
------------------------------
Code: 52??1223
Display: No "UNIT", "MARK" - "BLOCK", "MARKDT-".
Used by:
Cause: "BLOCK", "MARKDT-" was not found in "UNIT", "MARK" in the specified production program.
This report is made if the mark data and production program are in the same file and the above error is
detected.
Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "MARKDT-" in the specified production
program.
------------------------------
Code: 52??1224
Display: "UNIT", "MARK" - "BLOCK", "HEADER-" format error.
Used by:
Cause: "UNIT", "MARK" was read in the specified production program and a format error was detected in
"BLOCK", "HEADER-". This report is made if the mark data and production program are in the same file
and the above error is detected.
Remedy: Check the setting "UNIT", "MARK" - "BLOCK", "HEADER-" in the production program.
------------------------------
Code: 52??1225
Display: No "MARKTYPE" in "UNIT", "MARK" - "BLOCK", "HEADER-".
Used by:
Cause: "UNIT", "MARK" was read in the specified production program and there was no "MARKTYPE" in
"BLOCK", "HEADER-". This report is made if the mark data and production program are in the same file
and the above error is detected.
Remedy: Check the setting for "MARKTYPE" in "UNIT", "MARK"-"BLOCK" , "HEADER-".
------------------------------
Code: 52??1226
Display: "MARKTYPE" format error in "UNIT", "MARK" - "BLOCK", "HEADER-".
Used by:
Cause: "UNIT", "MARK" was read in the specified production program and a format error was detected in
"MARKTYPE" in "BLOCK", "HEADER-". This report is made if the mark data and production program are
in the same file and the above error is detected.
Remedy: Check the setting for "MARKTYPE" in "UNIT", "MARK" - "BLOCK", "HEADER-".
------------------------------
Code: 52??1227
Display: Format error in "UNIT", "MARK" - "BLOCK", "MARKDT-.
Used by:
Cause: "UNIT", "MARK" was read in the specified production program and a format error was detected in
"BLOCK", "MARKDT-". This report is made if the mark data and production program are in the same file
and the above error is detected.
Remedy: Check the settings for "UNIT", "MARK" - "BLOCK", "MARKDT" in the production program.
------------------------------
Code: 52??1230
第 2287 页
Display: There is a "UNIT", "MARK".
Used by:
Cause: Even though "UNIT", "MARK" is specified as being separate from the production program, "UNIT",
"MARK" exists in the production program. When downloading "UNIT", MARK" in the production program
is ignored.
Remedy: Check the "UNIT", "MARK" setting in the production program and the "FILESTRUCT" setting in
"UNIT", "STRUCT".
------------------------------
Code: 52??1231
Display: No "UNIT", "MARK" for F mark or "UNIT", "MARK" is not at the correct position.
Used by:
Cause: "UNIT", "MARK" for the F mark was not found in the specified production program or "UNIT",
"MARK" may not follow the correct unit. This report is made if the mark data and production program are
in the same file and the above error is detected. When downloading, the F mark data is set to its default
values.
Remedy: Check the setting for "UNIT", "MARK" in the production program. Furthermore, check the
setting for the "UNIT" line prior to "UNIT", "MARK".
------------------------------
Code: 52??1232
Display: No "UNIT", "MARK" for B mark or "UNIT", "MARK" is not at the correct position.
Used by:
Cause: "UNIT", "MARK" for the B mark was not found in the specified production program or "UNIT",
"MARK" may not follow the correct unit. This report is made if the mark data and production program are
in the same file and the above error is detected. When downloading, the B mark data is set to its default
values.
Remedy: Check the setting for "UNIT", "MARK" in the production program. Furthermore, check the
setting for the "UNIT" line prior to "UNIT", "MARK".
------------------------------
Code: 52??1233
Display: No "UNIT", "MARK" for M mark or "UNIT", "MARK" is not at the correct position.
Used by:
Cause: "UNIT", "MARK" for the M mark was not found in the specified production program or "UNIT",
"MARK" does not follow the correct unit. This report is made if the mark data and production program are
in the same file and the above error is detected. When downloading, the M mark data is set to its default
values.
Remedy: Check the setting for "UNIT", "MARK" in the production program. Furthermore, check the
setting for the "UNIT" line prior to "UNIT", "MARK".
------------------------------
Code: 52??1234
Display: No "UNIT", "MARK" for G mark or "UNIT", "MARK" is not at the correct position.
Used by:
Cause: "UNIT", "MARK" for the G mark was not found in the specified production program or "UNIT",
"MARK" does not follow the correct unit. This report is made if the mark data and production program are
in the same file and the above error is detected. When downloading, the G mark data is set to its default
values.
Remedy: Check the setting for "UNIT", "MARK" in the production program. Furthermore check the setting
for the "UNIT" line prior to "UNIT", "MARK".
------------------------------
Code: 52??1240
Display: Cannot find F mark file specification line.
Used by:
第 2288 页
Cause: The F mark file specification line at "GMKFN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in
the specified production program has been omitted. When downloading, the F mark data is set to its
default values.
Remedy: Check the "GMKFN" settings in the production program.
------------------------------
Code: 52??1241
Display: Cannot find the B mark file specification line.
Used by:
Cause: The B mark file specification line at "GMKBN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in
the specified production program has been omitted. When downloading, the B mark data is set to its
default values.
Remedy: Check the "GMKBN" settings in the production program.
------------------------------
Code: 52??1242
Display: Cannot find the M mark file specification line.
Used by:
Cause: The M mark file specification line at "GMKMN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in
the specified production program has been omitted. When downloading, the M mark data is set to its
default values.
Remedy: Check the "GMKMN" settings in the production program.
------------------------------
Code: 52??1243
Display: Cannot find the G mark file specification line.
Used by:
Cause: The G mark file specification line at "GMKGN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in
the specified production program has been omitted. When downloading, the G mark data is set to its
default values.
Remedy: Check the "GMKGN" settings in the production program.
------------------------------
Code: 52??1244
Display: Multiple F mark file specification lines.
Used by:
Cause: There are multiple F mark file specification lines at "GMKFN" in "UNIT", "PROGRAM" - "BLOCK",
"PGHEAD" in the specified production program. When downloading, the final line is taken to be the valid
one.
Remedy: Check the "GMKFN" settings in the production program.
------------------------------
Code: 52??1245
Display: Multiple B mark file specification lines.
Used by:
Cause: There are multiple B mark file specification lines at "GMKBN" in "UNIT", "PROGRAM" - "BLOCK",
"PGHEAD" in the specified production program. When downloading, the final line is taken to be the valid
one.
Remedy: Check the "GMKBN" setting in the production program.
------------------------------
Code: 52??1246
Display: Multiple M mark file specification lines.
Used by:
Cause: There are multiple M mark file specification lines at "GMKMN" in "UNIT", "PROGRAM" - "BLOCK",
"PGHEAD" in the specified production program. When downloading, the final line is taken to be the valid
one.