FUJI错误代码查询.pdf - 第1774页

Used by: Cause: Unable to pick parts. Remedy: Replenish the parts supply. ------------------------------ Code: 1D660003 Display: Used by: Cause: Unable to detect parts. Remedy: Check the image taken by vision processing.…

100%1 / 5282
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65C5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65C6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65C7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65D000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D65D080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D65E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D65F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D660002
Display:
第 1773 页
Used by:
Cause: Unable to pick parts.
Remedy: Replenish the parts supply.
------------------------------
Code: 1D660003
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660004
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660005
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660006
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660007
Display:
Used by:
Cause: Vision processing could not take a normal image. The upper or lower areas were too uneven or
there was foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D660008
Display:
Used by:
Cause: Vision processing could not take a normal image. The upper or lower areas were too uneven or
there was foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D660009
Display:
Used by:
第 1774 页
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D66000A
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D66000B
Display:
Used by:
Cause: The X length of the part is not within the acceptable range.
Remedy: Check the shape of the part.
------------------------------
Code: 1D66000C
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D66000D
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D66000E
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D66000F
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660010
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
第 1775 页