FUJI错误代码查询.pdf - 第759页

------------------------------ Code: 12071?49 Display: "ICM(PMC?,SCU?) Error Code:********" (QP2) "Command Response Timeout" (QP2)(QP132) PM?? ERROR Code:******** (QP132) Used by: QP242,QP201,QP202,QP…

100%1 / 5282
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12071?02
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Module Number" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The module number is incorrect.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12071?20
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Command Transmission Failed" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: ARCNET driver error (transmission failure).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12071?21
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Receiving Buffer Overflow" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: ARCNET driver error (receive buffer overflow).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12071?3A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Receiving Module Busy" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: ARCNET driver error (receiving module busy).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
第 758 页
------------------------------
Code: 12071?49
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Command Response Timeout" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A timeout occurred while waiting for a response.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Make sure the ARCNET cable has not become disconnected.
------------------------------
Code: 12071?50
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Command Format Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: There is a format error in the command.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12071?A0
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Ring Buffer Full" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The ring buffer is full.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12071?A1
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Communication Pipe Full" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The communication pipe is full.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12071?A2
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"ARCNET Full" (QP2)
PM?? ERROR Code:******** (QP132)
第 759 页
Used by: QP242,QP201,QP202,QP203,QP132
Cause: ARCNET full.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12071?A3
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Transmission Request Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Transmission request error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12072?01
Display: PMC?? ERROR [Code:12072?01]
Used by: QP132
Cause: PFU information was transmitted without a request for PFU information.
(value replacing "??" is module number)
Remedy: Attach the PFU to the machine, ensuring it is properly clamped. If the problem reoccurs after
clearing the error using the RESET button, or retransmitting the control software to the PMC using a
reset-start, there may be a problem such as a fault in the PFU to machine link board. Replace the
hardware in question, and if the problem still persists, output the PMC log and send it to Fuji for analysis.
------------------------------
Code: 12072?02
Display: PMC?? ERROR [Code:12072?02]
Used by: QP132
Cause: An error has been detected in PFU related data.
(value replacing "??" is module number)
Remedy: Attach the PFU to the machine, ensuring it is properly clamped. If the problem reoccurs after
clearing the error using the RESET button, or retransmitting the control software to the PMC using a
reset-start, there may be a problem such as a fault in the PFU to machine link board. Replace the
hardware in question, and if the problem still persists, output the PMC log and send it to Fuji for analysis.
------------------------------
Code: 12072?03
Display: PMC?? ERROR [Code:12072?03]
Used by: QP132
Cause: An error has been detected in PFU related data.
(value replacing "??" is module number)
Remedy: Attach the PFU to the machine, ensuring it is properly clamped. If the problem reoccurs after
clearing the error using the RESET button, or retransmitting the control software to the PMC using a
reset-start, there may be a problem such as a fault in the PFU to machine link board. Replace the
hardware in question, and if the problem still persists, output the PMC log and send it to Fuji for analysis.
------------------------------
Code: 12072?04
第 760 页