stage and slot number. Used by: Cause: Sequence data with and without feeder skip settings exist for the same stage/slot number. Remedy: Correct the sequence data so that all sequences for the same stage/slot number have…

100%1 / 5282
Display: There are sequences on the same board with the same mark number.
Used by:
Cause: A fiducial mark reading sequence exists which has duplicate mark numbers within a single
board.
Remedy: Revise either the "Board No." or "Mark No." in the sequence data.
------------------------------
Code: 2300E109
Display: Main mark number has not been set.
Used by:
Cause: The main mark number in the part placement sequence is set as "0".
Remedy: Specify a main mark number setting other than "0".
------------------------------
Code: 2300E10A
Display: Sub mark number has not been set.
Used by:
Cause: The sub-mark number in the part placement sequence is set as "0".
Remedy: Specify a sub-mark number setting other than "0".
------------------------------
Code: 2300E10B
Display: The main mark and sub mark numbers are identical.
Used by:
Cause: The same setting value is specified for both the main mark number and the sub-mark number in
the part placement sequence.
Remedy: Specify setting values so that the main mark number and sub-mark number are different.
------------------------------
Code: 2300E10C
Display: The fiducial mark sequence for the mark number set as the main mark cannot be found.
Used by:
Cause: A fiducial mark reading sequence which contains the specified (in the part placement sequence)
main mark number cannot be found.
Remedy: Set the fiducial mark reading sequence for the specified main mark number to occur before the
part placement sequence.
------------------------------
Code: 2300E10D
Display: The fiducial mark sequence for the mark number set as the sub mark cannot be found.
Used by:
Cause: A fiducial mark reading sequence which contains the specified (in the part placement sequence)
sub-mark number cannot be found.
Remedy: Set the fiducial mark reading sequence for the specified sub-mark number to occur before the
part placement sequence.
------------------------------
Code: 2300E10E
Display: Board skip settings of '0' and '1' have both been specified in the sequence data for the same
board.
Used by:
Cause: Sequence data with and without board skip settings exist for the same board.
Remedy: Correct the sequence data so that all sequences for the same board have the same board skip
settings.
------------------------------
Code: 2300E10F
Display: Feeder skip settings of '0' and '1' have both been specified in the sequence data for the same
第 2127 页
stage and slot number.
Used by:
Cause: Sequence data with and without feeder skip settings exist for the same stage/slot number.
Remedy: Correct the sequence data so that all sequences for the same stage/slot number have the same
feeder skip settings.
------------------------------
Code: 2300E110
Display: The total number of board skip mark read sequences and fiducial mark read sequences exceeds
255.
Used by:
Cause: The total number of board skip mark read sequences and fiducial mark read sequences exceeds
255.
Remedy: Correct the sequence data so that the total number of board skip mark read sequences
(Sequence type:B) and fiducial mark read sequences (Sequence type:F) is 255 or less.
------------------------------
Code: 2300E111
Display: The "Sequence Comment" sequence specified for the "Place Before" sequence does not exist on the
same board.
Used by:
Cause: The "Sequence Comment" sequence specified for the "Place Before" sequence does not exist on the
same board.
Remedy: Specify a "Sequence Comment" sequence that applies to the same board as that of the "Place
Before" sequence.
The "Place Before" sequence is ignored where the "Sequence Comment" sequence does not apply to the
same board.
------------------------------
Code: 2300E112
Display: The same name has been allocated to "Place Before" and "Sequence Comment".
Used by:
Cause: The same name has been allocated to the "Place Before" and "Sequence Comment" sequences.
Remedy: Specify different names for the "Place Before" and "Sequence Comment" sequences.
------------------------------
Code: 2300E113
Display: Duplicate "Sequence Comment" sequences exist for the same board.
Used by:
Cause: Duplicate "Sequence Comment" sequences exist for the same board.
Remedy: Create sequences so that "Sequence Comment" sequences are not duplicated for the same
board.
------------------------------
Code: 2300E114
Display: The "Place Before" sequence order is incorrect.
Used by:
Cause: The "Place Before" sequence order is incorrect.
Remedy: Change the "Place Before" sequence order so that the "Place Before" sequence is positioned
before the "Sequence Comment" sequence.
------------------------------
Code: 2300E115
Display: Mark data does not exist for the specified mark name.
Used by:
Cause: Either the mark name is input incorrectly in the sequence data, or the mark data does not exist.
Remedy: Check the mark data. If mark data does exist, then check the mark name in the sequence data.
第 2128 页
------------------------------
Code: 2300E116
Display: The mark name is not specified.
Used by:
Cause: The mark name field in the mark sequence is blank.
Remedy: Specify the mark name to match the existing mark data.
------------------------------
Code: 2300E117
Display: The mark name is not specified. The No. 1 mark from the mark edit screen is being used.
Used by:
Cause: A mark name has not been specified in the sequence editor screen. The No. 1, type F mark from
the mark editor screen is being used.
Remedy: If there is a problem with the mark being used, then specify a different mark name in the
sequence edit screen.
------------------------------
Code: 2300E118
Display: The global skip mark sequence must be positioned earlier in the program than the board skip
mark sequence.
Used by:
Cause: The global skip mark sequence must be positioned earlier in the program than the board skip
mark sequence.
Remedy: Input the global skip mark sequence at an earlier sequence no. than the board skip mark
sequence.
------------------------------
Code: 2300E119
Display: When referencing fiducial marks for global / board skip mark sequences, the board no. for the
fiducial mark sequence must be 0.
Used by:
Cause: When referencing fiducial marks for global / board skip mark sequences, the board no. for the
fiducial mark sequence must be 0.
Remedy: Set the board no. for a fiducial mark sequence to 0 when referencing fiducial marks for global /
board skip mark sequences.
------------------------------
Code: 2300E11A
Display: The fiducial mark sequence must be positioned earlier in the program than the global / board
skip mark sequence.
Used by:
Cause: The fiducial mark sequence must be positioned earlier in the program than the global / board
skip mark sequence.
Remedy: Input the fiducial mark sequence at an earlier sequence no. than the global / board skip mark
sequence.
------------------------------
Code: 2300E11B
Display: A board skip mark sequence for a particular board no. must be positioned earlier in the program
than any placement sequences for that board.
Used by:
Cause: A board skip mark sequence for a particular board no. must be positioned earlier in the program
than any placement sequences for that board.
Remedy: Input the board skip mark sequence for a particular board no. at an earlier sequence no. than
any placement sequences for that board.
------------------------------