Used by: QP242 Cause: The flux cylinder size "PLM? Flux Cylinder Size"(QP2) setting is out of range. "?" represents the module number. Remedy: Input a value between 1-1000 for Proper data item, "…

100%1 / 5282
Code: 11022A29
Display: Same as code
Used by: QP242
Cause: No value has been set for the "PLM? Feeding Off Timer (QP2)" parameter, which determines how
long feeding by the IP-series feeder is turned off. The value for the "?" in the parameter name indicates the
module number.
Remedy: Set a value for the "PLM? Feeding Off Timer (QP2)" in the Proper data
------------------------------
Code: 11022A2A
Display: Same as code
Used by: QP242,QP202
Cause: The "PLM? PX In Convyr Speed (QP2)" setting (which determines the speed of the board conveyer
PX-axis during board loading) is outside the valid range. The value for the "?" in the parameter name
indicates the module number.
Remedy: Set a value from 38 to 1000 for the "PLM? PX In Convyr Speed (QP2)" parameter in the Proper
data.
------------------------------
Code: 11022A2B
Display: Same as code
Used by: QP242,QP202
Cause: The "PLM? PX Out Convyr Speed (QP2)" setting (which determines the speed of the board
conveyer PX-axis during board unloading) is outside the valid range. The value for the "?" in the
parameter name indicates the module number.
Remedy: Set a value from 38 to 1000 for the "PLM? PX Out Convyr Speed (QP2)" parameter in the Proper
data.
------------------------------
Code: 11022A2C
Display: Same as code
Used by: QP242,QP202
Cause: The "PLM? PX Red Convyr Speed (QP2)" setting (which determines the speed of the board
conveyer PX-axis during board deceleration) is outside the valid range. The value for the "?" in the
parameter name indicates the module number.
Remedy: Set a value from 5 to 37 for the "PLM? PX Red Convyr Speed (QP2)" parameter in the Proper
data.
------------------------------
Code: 11022A2D
Display: "Data check error [11022A2D]"
Used by: QP242,QP201,QP202,QP203
Cause: The number of the communication port to be used by the ID controller unit either has not been
set, or duplicates another setting.
Remedy: Check the number of the port being used and correct the setting.
------------------------------
Code: 11022A2E
Display: "Data check error [11022A2E]"
Used by: QP242
Cause: The number of the communication port to be used by the tape end sensor either has not been set,
or duplicates another setting.
Remedy: Check the number of the port being used and correct the setting.
------------------------------
Code: 11022A2F
Display: "Data check error [11022A2F]"
第 174 页
Used by: QP242
Cause: The flux cylinder size "PLM? Flux Cylinder Size"(QP2) setting is out of range. "?" represents the
module number.
Remedy: Input a value between 1-1000 for Proper data item, "PLM? Flux Cylinder Size"(QP2).
------------------------------
Code: 11022A30
Display: "Data check error [11022A30]"
Used by: QP242
Cause: The flux pump controller port number "PLM? Pump SCU Port"(QP2) setting is out of range. "?"
represents the module number.
Remedy: Specify the port number for the flux pump controller in Proper data item, "PLM? Pump SCU
Port"(QP2). Available SCU port numbers are 1-3.
------------------------------
Code: 11022A31
Display: Same as code.
Used by: QP242
Cause: The flux type has been specified at Proper data item, "PLM? Flux Dispence Type".
Remedy: Ensure that Proper data item, "PLM? Flux Dispence Type" (APL/CLT) is set to "0".
------------------------------
Code: 11022A32
Display: Same as code.
Used by: QP132
Cause: Proper data settings for heat expansion compensation are not correct.
Remedy: Proper data
485:T_MARK Check Interval
486:T_MARK Check Tolerance
487:Thermal Expansion Compensation
488:T_MARK Check PM No.
Ensure these settings are specified correctly.
------------------------------
Code: 11022A33
Display: Same as code.
Used by: QP242
Cause: The module width and supply unit type are not compatible.
Remedy: Check the setting of the following Proper data items ;
PLM? Module Width
PLM? Device Type
"?" represents the module number.
------------------------------
Code: 11022A34
Display: MX/MY-axis tolerance error.
Used by: QP132
Cause: The Proper data for the MX or MY-axis is not correct. The resolution level of the MX and MY-axis
has been changed from V1.43 and later. This error occurs if an unsuitable value is detected in 1 pulse 5
um mode or 1 pulse 2.5 um mode. Specify 2000H at Proper data item "12: Machine Status B" to set the
resolution mode to 5 um. If this setting is not made, a default setting of 2.5 um is used.
Remedy: Correctly set Proper data for the MX and MY-axis. If the version has been upgraded, double the
setting at the Proper data items listed below, and make the required changes to the servo board switch
settings. Refer to the appropriate upgrade report for further details.
141: Mark Read Position MXC
142: Mark Read Position MYC
第 175 页
145: PCB Pickup position MX
146: PCB Landing position MX
147: PCB Landing position MX_FWD
162: Max_Limit_Position_MX
163: Max_Limit_Position_MY
166: Min_Limit_Position_MX
162: Min_Limit_Position_MY
For example, if the item "141: Mark Read Position MXC" is set to "140000", this should be changed
to "280000", and retransmission then performed.
------------------------------
Code: 11022A35
Display: Same as the code
Used by: QP201 (APL)
Cause: Use of the raised part detection sensor has been enabled in Proper data, but the appropriate
setting has not been made for carrier unclamping.
Remedy: Check the settings at the Proper data item, "PLM? Machine Status" (? represents the module
number).
Raised part detection sensor attached: 0000 1000 0000 0000
Independent carrier unclamping: 0000 0100 0000 0000
------------------------------
Code: 11022A36
Display: Same as the code
Used by: QP201 (APL)
Cause: The raised part recovery setting has been made more than once.
Remedy: Specify just one of the following settings at the Proper data item, "Machine Status B".
Reinspect: 0001 0000 0000 0000
Reselect: 0010 0000 0000 0000
Push part: 0100 0000 0000 0000
Error: 1000 0000 0000 0000
------------------------------
Code: 11022A37
Display: Same as the code
Used by: QP201 (APL)
Cause: Data necessary to perform a raised part check has not been specified.
Remedy: Make settings at the following Proper data items
Laser Check Speed
Laser Zero Point 1
Laser Check Point 1
------------------------------
Code: 11022A38
Display: "PM?? @ ERROR Code:********"
PMC SERVO PARAMETER ERROR
Used by: QP132
Cause: PMC servo parameter is not correctly set in Proper data.
The Moule number is reqresented by ??, and the axis is reqresented by @.
Remedy: Check the PMC servo parameter for the displayed Module number and axis, and make
adjustments as required.
------------------------------
Code: 11022A39
Display: Same as the code
Used by: QP242