Cause: The part size is larger than the backlight size. Remedy: Check the part and backlight sizes. ------------------------------ Code: 1CA00F04 Display: 1CA00F04 Used by: Cause: A Vision_type setting was specified that…

100%1 / 5282
Used by:
Cause: The lead pitch is much narrower than the value entered in Part data.
Remedy: Enter the correct value in Part data.
------------------------------
Code: 1CA00004
Display: 1CA00004
Used by:
Cause: A lead is bent.
Remedy: A lead is bent in excess of the tolerance set in Pitch_limit in part data.
------------------------------
Code: 1CA00005
Display: 1CA00005
Used by:
Cause: There is not enough contrast between the part and its background for vision processing.
Remedy: Check the fluorescent plate on the nozzle sticker and the condition of the lighting system.
------------------------------
Code: 1CA00006
Display: 1CA00006
Used by:
Cause: Part data has not been registered.
Remedy: Failed to register part data. Check if part data and vision type setting are correct. If part data is
correct, the vision system may be faulty. Contact Fuji.
------------------------------
Code: 1CA00007
Display: 1CA00007
Used by:
Cause: The resolution is incorrect.
Remedy: The resolution is set to "0" or lower. Check Proper data.
------------------------------
Code: 1CA00008
Display: 1CA00008
Used by:
Cause: The nozzle center is incorrect.
Remedy: The nozzle center is outside the permissible range. Check Proper data.
------------------------------
Code: 1CA00009
Display: 1CA00009
Used by:
Cause: Nozzle data is incorrect.
Remedy: The nozzle type or backlight type is incorrect, or the nozzle size is set to zero or less. Check
Nozzle data.
------------------------------
Code: 1CA0000A
Display: 1CA0000A
Used by:
Cause: The direction setting is incorrect.
Remedy: The direction setting can be set between 1 and 8. Check the setting.
------------------------------
Code: 1CA0000B
Display: 1CA0000B
Used by:
第 1188 页
Cause: The part size is larger than the backlight size.
Remedy: Check the part and backlight sizes.
------------------------------
Code: 1CA00F04
Display: 1CA00F04
Used by:
Cause: A Vision_type setting was specified that does not exist in part data.
Remedy: Verify what types of vision types in part data can be utilized with the vision processing software
that is currently being used. In the case that part data is correct then there was a failure with the
initialization of the vision processing system during startup. If this error occurs contact Fuji.
------------------------------
Code: 1CA??001
Display: 1CA??001
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 14, 15, 16, 17, 18, or 28 this signifies that the part is larger than the diameter of the specified
background disk. If "??" equals 64, 78, 79, 7B, 7C, 96, 97, 98, 99or A0 then the part data description is
incorrect.
If "??" equal FC then the part is smaller than the specified nozzle size.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 14, 15, 16, 17, 18, or 28 then the production program should be
corrected so that a nozzle is employed that uses a background disk which is larger than the one currently
being used. If "??" equals 64, 78, 79, 7B, 7C, 96, 97, 98, 99or A0 this error will occur when the part is
being registered in the vision processing system. Vision processing can in fact be executed in this case,
however, the results cannot be guaranteed. Inspect the part data. If "??" equal FC then the part could not
be found because it is smaller than the specified nozzle size. Check for errors in the nozzle data.
------------------------------
Code: 1CA??002
Display: 1CA??002
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 14, 15, 16, 17, 18, or 28 this signifies that the part is smaller than the specified nozzle diameter.
If "??" equals 1E, 64, 78, 79, 7B, 7C, 96, 97, 98, 99, A0, AC, B4, F0, F1 or F2 then the part data
description is incorrect. If "??" equal FC then contour tracing cannot begin due to a bent nozzle.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 14, 15, 16, 17, 18, or 28 then the part is smaller than the specified
nozzle diameter and the part in question cannot be recognized. Make sure the nozzle data is correct. If
"??" equals 1E, 64, 78, 79, 7B, 7C, 96, 97, 98, 99, A0, AC, B4, F0, F1 or F2 this error will occur when the
part is being registered in the vision processing system. Vision processing cannot be executed. Inspect
the part data. If "??" equal FC then the nozzle's rotational center is not aligned with the nozzle image.
Check for a bent nozzle.
------------------------------
Code: 1CA??003
Display: 1CA??003
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 14, 15, 16, 17, 18, or 28 this signifies that there is an error in the part data. If "??" equal FC then
the part's X-direction size exceeds the tolerance value.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 14, 15, 16, or 17 the description in Bodysize in part data is
incorrect. Make the necessary corrections to this data item in part data. If "??" equals 18 or 28 the
description of the part in part data is incorrect. Make the necessary corrections in part data. If "??" equal
FC then the part size is incorrect. Correct the part data.
------------------------------
第 1189 页
Code: 1CA??004
Display: 1CA??004
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 15, or 18 this signifies that the search for the part boundaries could not begin because the nozzle
is bent. If "??" equals 14 or 28 then there is an error in the descriptions of the leads in part data. If "??"
equals 16 or 17 this indicates that the lead descriptions in part datahave been set to "0". If "??" equal FC
then the part's Y-direction size exceeds the tolerance value.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 15, or 18 then the nozzle center of rotation and the image of the
nozzle do not conform. Make sure the nozzle is not bent. If "??" equals 14, 16, 17, or 28 then make the
necessary corrections to the lead descriptions in part data. If "??" equal FC then the part size is incorrect.
Correct the part data.
------------------------------
Code: 1CA??005
Display: 1CA??005
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 15, or 18 this signifies that the part outline could not be found. If "??" equals 14 or 28 this
indicates that the lead pitch setting is either too narrow or too wide. If "??" equals 16 or 17 then the lead
width is smaller than the lead pitch. If "??" equal 7B, 7C, 96, 97, 98, 99, F0 or FE then invalid "P_Pattern"
value.
Remedy: If "??" equals 0A, 0B, 0C, or 0D then make sure that there are no unexpected protrusions
resulting from a burr or something being stuck to the part. If "??" equals 14, 16, 17, or 28 then make the
necessary corrections in part data. If "??" equals 15 or 18 then make sure that there are no unexpected
protrusions resulting from a burr or something being stuck to the part. If there is a protrusion on any
side other than the side opposite the lead segment on one portion of the part, then this Visio _type cannot
be used. Try using vision processing number 20 or 100 in such a case. If "??" equal 7B, 7C, 96, 97, 98,
99, F0 or FE then "P_Pattern" must be 1 to 16, 23, 24, 33 or 34.Check the "P_Pattern" setting.
------------------------------
Code: 1CA??006
Display: 1CA??006
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 15, or 18 this signifies that part positioning was not possible because there were too many
segments in the outline of the part. If "??" equals 14 or 28 then there are bent leads. If "??" equals 16 or
17 this indicates that the part could not be found because the nozzle was bent. If "??" equal 64, 78, 79,
7A, 7B, 7C, 96, 97, 98, 99, A0, F0 or FE then invalid "Result" value.
Remedy: If "??" equals 0A, 0B, 0C, or 0D then the part has too many slight protrusions such as burrs
causing breaks in the linear segments. If "??" equals 14 or 28 this indicates that the bend in the leads has
exceeded the permissible range specified in the pitch limit in part data. If "??" equals 15 or 18 then the
part has too many slight protrusions such as burrs causing breaks in the linear segments. Try
Vision_type 20 or 100 in such a case. If "??" equals 16 or 17 then either re-measure the nozzl center or
replace with another nozzle. If "??" equal 64, 78, 79, 7A, 7B, 7C, 96, 97, 98, 99, A0, F0 or FE then this
algorithm is not compatible with matrix tables.Check whether 128 is input at "Result".
------------------------------
Code: 1CA??007
Display: 1CA??007
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 15, or 18 then the part pickup status is bad. If "??" equals 14 or 28 this indicates that not a
single lead was detected. If "??" equals 16 or 17, the inspected leads were smaller than specified. If "??"
第 1190 页