FUJI错误代码查询.pdf - 第4824页
YY:料盘供料器种类·位置 01:料盘供料器MA 02:料盘供料器MB 03:料盘供料器MC 04:料盘供料器LA 05:料盘供料器LB ) Remedy: 请关闭主电源开关后重新打开,再次进行料盘供料器定位点读取。 ------------------------------ Code: 95B40000 Display: 影像处理装置异常 Used by: NXT,AIM Cause: 可考虑以下的原因。 影像处理装置的版本不一致 …
Code: 95B00000
Display: An internal processing error occurred
Used by: NXT,AIM
Cause: The process was discontinued due to an illegal process within the system.
( Additional )
Remedy: If this does not resolve the problem, acquire trace data from the machine under the conditions in
which the error occurs, and contact your Fuji representative.Turn off the main switch and restart the
machine.
------------------------------
Code: 95B10000
Display: 意想不到的异常
Used by: NXT,AIM
Cause: 在种类的取得、标记的确认、固有值的取得及设定等中发生了异常。
( 补充编码 00XXYY00
XX:平台号码
01:平台1
02:平台2
YY:料盘供料器种类·位置
01:料盘供料器MA
02:料盘供料器MB
03:料盘供料器MC
04:料盘供料器LA
05:料盘供料器LB )
Remedy: 请关闭主电源开关后重新打开,再次进行料盘供料器定位点读取。
------------------------------
Code: 95B20000
Display: 料盘供料器往复臂位置异常
Used by: NXT,AIM
Cause: 在料盘供料器位置识别中,料盘供料器往复臂位置不在前进端。
( 补充编码 00XXYY00
XX:平台号码
01:平台1
02:平台2
YY:料盘供料器种类·位置
01:料盘供料器MA
02:料盘供料器MB
03:料盘供料器MC
04:料盘供料器LA
05:料盘供料器LB )
Remedy: 1.请确认料盘供料器是否被连接到料站托架上。
2.请按下料盘供料器操作面板SW [▲],使料盘供料器往复臂移动到前进端。
3.有可能料盘供料器发生故障,请进行修理·维修保养。
------------------------------
Code: 95B30000
Display: XY机械手异常
Used by: NXT,AIM
Cause: 想要使XY机械手动作时发生了异常。
( 补充编码 00XXYY00
XX:平台号码
01:平台1
02:平台2
第 4823 页
YY:料盘供料器种类·位置
01:料盘供料器MA
02:料盘供料器MB
03:料盘供料器MC
04:料盘供料器LA
05:料盘供料器LB )
Remedy: 请关闭主电源开关后重新打开,再次进行料盘供料器定位点读取。
------------------------------
Code: 95B40000
Display: 影像处理装置异常
Used by: NXT,AIM
Cause: 可考虑以下的原因。
影像处理装置的版本不一致
影像处理装置的拍摄准备指示
影像处理装置的拍摄指示
影像处理装置的等待暴光结束
影像处理装置的F定位点拍摄处理
( 补充编码 00XXYY00
XX:平台号码
01:平台1
02:平台2
YY:料盘供料器种类·位置
01:料盘供料器MA
02:料盘供料器MB
03:料盘供料器MC
04:料盘供料器LA
05:料盘供料器LB )
Remedy: 1.请确认触发电路。
2.请确认版本是否不一致。
3.请更换影像处理电路板。
------------------------------
Code: 95B50000
Display: 影像处理装置光源IO异常
Used by: NXT,AIM
Cause: 在相机的光源I/O中发生了异常。
( 补充编码 00XXYY00
XX:平台号码
01:平台1
02:平台2
YY:料盘供料器种类·位置
01:料盘供料器MA
02:料盘供料器MB
03:料盘供料器MC
04:料盘供料器LA
05:料盘供料器LB )
Remedy: 1.请进行I/O检查。
2.如果I/O检查的结果为异常,请更换相机。
3.请关闭主电源开关后重新打开,再次进行料盘供料器定位点读取。
------------------------------
Code: 95B60000
Display: 影像处理结果取得异常
第 4824 页
Used by: NXT,AIM
Cause: 在定位点读取中发生了不良。
可考虑以下的原因。
·相机灯不亮
·在定位点上有元件等异物
·被搬运轨道导轨遮住
·定位点缺损
( 补充编码 00XXYY00
XX:平台号码
01:平台1
02:平台2
YY:料盘供料器种类·位置
01:料盘供料器MA
02:料盘供料器MB
03:料盘供料器MC
04:料盘供料器LA
05:料盘供料器LB )
Remedy: 如果影像暗淡时
1.请确认相机灯是否亮灯。
2.请确认触发电路。
如果影像不清晰时
1.请确认定位点是否缺损。
2.请清扫相机镜头。
------------------------------
Code: 95C00000
Display: An internal processing error occurred
Used by: NXT,AIM
Cause: The process was discontinued due to an illegal process within the system.
( Additional )
Remedy: If this does not resolve the problem, acquire trace data from the machine under the conditions in
which the error occurs, and contact your Fuji representative.Turn off the main switch and restart the
machine.
------------------------------
Code: 95C10000
Display: 在Dip动作的加压力控制中发生了紧急停止。
Used by: NXT,AIM
Cause: 由于在使用加压力控制下降Z轴时发生了紧急停止,Z轴的下降动作停止了。
根据停止位置,元件一直浸没在Flux槽内,Flux有可能附着在吸嘴上。
另外,也可考虑元件的落下。
(补充编码)
Remedy: 如果元件落到Flux槽内,请取除元件后重新开始生产。
同时请确认Flux是否附着在吸嘴上。
如果附着时,成为缺元件或误贴装的原因,因此请清扫。
如果没有问题,就这样请重新开始生产。
------------------------------
Code: 95C20000
Display: 助焊剂单元高度异常
Used by: NXT,AIM
Cause: 助焊剂单元的高度偏离基准。( 补充编码 ) NXTR:助焊剂单元的高度偏离基准。高度的公差值:测定的3点
都在盘边缘的基准高度(Z0-1mm)±300um以内。(补充编码)
Remedy: 1.请清扫单元的测定面 2.不能解决时,请收集发生错误时的跟踪数据并联系本公司的代理店或售后服务人
第 4825 页