Cause: Abolished. Remedy: Abolished. ------------------------------ Code: 15040877 Display: UNLD MANI RISE FAIL Loader error: 15040877 Used by: QP132 Cause: The exit board transport upper-limit sensor went off during mov…
Cause: The ascend and descend operation of the manipulator on the unloading side was not completed
within the set amount of time.
Remedy: Check the ascend/descend operation of the manipulator on the unloading side and the
operation of the exit board transport upper-limit and lower-limit sensors.
------------------------------
Code: 1504086C
Display: UNLD MANI PCB PICKUP ERROR
Loader error: 1504086C
Used by: QP132
Cause: The unloading side manipulator failed to grab the board from the pallet during the pick operation.
Remedy: Make sure the board unclamp operation is working correctly. Check the operating status of the
exit transport board-check sensor. Make sure that the position at which the board is grabbed from the
pallet is correct.
------------------------------
Code: 1504086D
Display: UNLD MANI PCB PLACE ERROR
Loader error: 1504086D
Used by: QP132
Cause: The unloading side manipulator failed to place the board on the out-conveyor.
Remedy: Check the operating status of the exit transport board-check sensor and the out-conveyor
board-arrival-check sensor.
------------------------------
Code: 1504086F
Display: UNLD MANI PCB LOSE ERROR
Loader error: 1504086F
Used by: QP132
Cause: The board was lost during movement of the unloading side manipulator.
Remedy: Make sure that the board did not slip off during the manipulator movement. Check the
operating status of the exit transport board-check sensor.
------------------------------
Code: 15040872
Display: UNLD MANI TURN TUP
Loader error: 15040872
Used by: QP132
Cause: The rotation operation of the unloading side manipulator was not completed within the set
amount of time.
Remedy: Check the rotation operation of the unloading side manipulator and the operation of the exit
board transport rotation sensor.
------------------------------
Code: 15040873
Display: UNLD MANI BACK TUP
Loader error: 15040873
Used by: QP132
Cause: The return rotation operation of the unloading side manipulator was not completed within the set
amount of time.
Remedy: Check the return operation of the unloading side manipulator and the operation of the exit
board transport return sensor.
------------------------------
Code: 15040875
Display: Abolished.
Used by: QP122
第 1156 页
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040877
Display: UNLD MANI RISE FAIL
Loader error: 15040877
Used by: QP132
Cause: The exit board transport upper-limit sensor went off during movement of the unloading side
manipulator.
Remedy: Make sure that the air pressure used to raise the board which is to be transported out, has not
fallen. Check the operation of the exit board transport upper-limit sensor.
------------------------------
Code: 15040880
Display: UNLD 10-SHIFT FORWARD TUP
Loader error: 15040880
Used by: QP132
Cause: The out-conveyor pallet pusher (which shifts the pallet a further 10 mm) did not reach its
extended position in the given time.
Remedy: Check the pallet pusher is at its extended position (X073: P.OUT PLT RSFT) using I/O
commands and adjust if necessary.
------------------------------
Code: 15040881
Display: UNLD 10-SHIFT BACKWARD TUP
Loader error: 15040881
Used by: QP132
Cause: The out-conveyor pallet pusher (which shifts the pallet a further 10 mm) did not reach its retract
position in the given time.
Remedy: Check the pallet pusher is at its retract position (X074: P.OUT PLT LSFT)using I/O commands
and adjust if necessary.
------------------------------
Code: 15040882
Display: UNLD TRANS FORWARD TUP
Loader error: 15040882
Used by: QP132
Cause: The pallet pusher that moves a pallet from the pallet unloader to the return-conveyor did not
finish extending in the given time.
Remedy: Check the X075: P.OUT PUSH FED operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040883
Display: UNLD TRANS BACKWARD TUP
Loader error: 15040883
Used by: QP132
Cause: The pallet pusher that moves a pallet from the pallet unloader to the return-conveyor did not
finish retracting in the given time.
Remedy: Check the X076: P.OUT PUSH BED operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040884
Display: UNLD-RCV CHANGE TUP
Loader error: 15040884
Used by: QP132
Cause: After being unloaded to the return-conveyor, the pallet did not activate the return-conveyor pass-
第 1157 页
through sensor at the in-conveyor end.
Remedy: Check the X068: P.IN ARRV CK operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040885
Display: UNLD-CHGMODULE CHANGE TUP
Loader error: 15040885
Used by: QP132
Cause: The pallet did not activate the unloading pallet interlock when it was moved from the pallet
unloader to the changeover module.
Remedy: Check the X027: P.OUT INTERLCK operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040886
Display: CHGMODULE-UNLD CHANGE TUP
Loader error: 15040886
Used by: QP132
Cause: The pallet did not activate the unloading pallet interlock when it was moved from the changeover
module to the pallet unloader.
Remedy: Check the X027: P.OUT INTERLCK operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040887
Display: Chgst Bar Ext Pos Error
Loader error: 15040887
Used by: QP132
Cause: The change station bar has not reached its extended position in the time allowed.
Remedy: Check the operation of the change station bar with I/O X06C: CHG BAR FWEND and make any
necessary adjustments.
------------------------------
Code: 15040888
Display: Chgst Bar Ret Pos Error
Loader error: 15040888
Used by: QP132
Cause: The change station bar has not reached its retract position in the time allowed.
Remedy: Check the operation of the change station bar with I/O X06C: CHG BAR BWEND and make any
necessary adjustments.
------------------------------
Code: 15040901
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040A01
Display: 电路板载入异常 往复臂L
Used by: NXTP
Cause: 从前道工序到换乘传感器或者电路板到达传感器为止电路板没有到达。
Remedy: 1.请确认搬运轨道间的电路板载入是否顺畅。
2.请确认换乘传感器(RX080,RX081),电路板到达传感器(RX082)能正常检测电路板。
<img src="$LKEY_ERRIMG_MC$/15040A01.PNG">
------------------------------
Code: 15040A02
Display: 电路板载入异常 往复臂R