------------------------------ Code: 12054036 Display: Used by: Cause: The X-transport could not open and close in the specified time. Remedy: Check that the load on the cylinder is not unreasonable. --------------------…

100%1 / 5282
Code: 1205402F
Display: "Air Cylinder Cycle Alarm Cleaner Released"
Used by: GSP5,GP551,GP6
Cause: Removal of the notch required longer than the specified time.
Remedy: Use an I/O command to check the sensor.
------------------------------
Code: 12054030
Display: "Air Cylinder Cycle Alarm Cleaner Connected"
Used by: GSP5,GP551,GP6
Cause: Insertion of the notch required longer than the specified time.
Remedy: Use an I/O command to check the sensor (GSP5, GP6).
------------------------------
Code: 12054031
Display: 周期异常 汽缸 清洁器工作头关闭
Used by: GP551,GP6,GPX,NXTP
Cause: 关闭清洁器工作头超过了规定时间以上。 清洁器上下的进入端或者退出端没有在规定的时间内ON。
清洁器的上升端,下降端的传感器同时ON了。 (GPX)
Remedy: 请通过I/O确认传感器。 1.请除去清洁器上下时的障碍物。
2.请使用I/O进行清洁器上下进入确认,清洁器上下解除确认的传感器的检查。(RX018,019)(请与本公司的
Support联系)
3.UpDown Sensor Adjustment:请进行清洁器上升下降端的传感器位置的调整。(GPX)
<img src="$LKEY_ERRIMG_MC$/12054031.PNG">
------------------------------
Code: 12054032
Display: 周期异常 汽缸 清洁器工作头开启
Used by: GSP5,GP551,GP6,GPX,NXTP
Cause: 开启清洁器工作头超出规定时间以上。
Remedy: 请通过I/O确认传感器。
<img src="$LKEY_ERRIMG_MC$/12054032.PNG">
------------------------------
Code: 12054033
Display:
Used by: GSP5
Cause: The specified operation did not finish within the specified time.
Remedy: The cylinder which moves the solder supply in the Y-direction is broken or disconnected. Check
the cylinder movement and check the connections.
------------------------------
Code: 12054034
Display:
Used by: GSP5,GP6,NXTP
Cause: The specified operation did not finish within the specified time.
Remedy: The cylinder which moves the solder supply up and down is broken, disconnected or is being
prevented from moving by some interfering object. Check the cylinder movement, check the connections
and check for any interfering objects.
<img src="$LKEY_ERRIMG_MC$/12054034.PNG">
------------------------------
Code: 12054035
Display:
Used by:
Cause: The X-chuck could not open and close in the specified time.
Remedy: Check that the load on the cylinder is not unreasonable.
第 548 页
------------------------------
Code: 12054036
Display:
Used by:
Cause: The X-transport could not open and close in the specified time.
Remedy: Check that the load on the cylinder is not unreasonable.
------------------------------
Code: 12054037
Display:
Used by: GSP5
Cause: Mask reception advance or retraction takes too long.
Remedy: Check that the mask reception advance and retract limit sensors work.
------------------------------
Code: 12054038
Display:
Used by: GSP5
Cause: The solder recovery ascent or descent takes too long.
Remedy: Check that the solder recovery ascent or descent limit sensors work.
------------------------------
Code: 12054039
Display:
Used by: GSP5
Cause: A camera station cycle alarm has occurred. The camera station could not move to its target
position within the specified time. Alternately, the advance or retract limit sensors are not working
properly.
Remedy: Check for interference at the camera station.Check the advance and retract limit sensors.
------------------------------
Code: 1205403A
Display: 周期异常 刮刀架
Used by: GSP5,GP551,GP6,GPX
Cause: 在刮刀架的上升或下降中发生了超时。
Remedy: 请确认刮刀架的传感器的输入。
<img src="$LKEY_ERRIMG_MC$/EI0024.bmp">
------------------------------
Code: 1205403B
Display: Cycle Alarm Stencil Top Clamp (GSP5, GP6)
Used by: GSP5,GP551,GP6
Cause: The top clamp on the stencil did not work correctly. Or the stencil top clamp check sensor failed
to work correctly.
Remedy: Check the output and input of the stencil top clamp sensor using the I/O check operation.
------------------------------
Code: 1205403C
Display:
Used by:
Cause: The stroke cannot ascend or descend. Alternately, the stroke lower limit sensor is broken.
Remedy: Check the operation of the stroke at the I/O board, and check the sensors.
------------------------------
Code: 1205403D
Display:
Used by:
Cause: The stroke frame clamper cannot operate. Alternately, the stroke frame clamper confirmation
第 549 页
sensor is broken.
Remedy: Check the operation of the clamper at the I/O board, and check the sensors.
------------------------------
Code: 1205403E
Display:
Used by:
Cause: The stroke frame unclamper cannot operate. Alternately, the stroke frame unclamper
confirmation sensor is broken.
Remedy: Check the operation of the unclamper at the I/O board, and check the sensors.
------------------------------
Code: 1205403F
Display: The tape cutter error.
Used by: CP-732E,CP-742ME,CP-742E,CP-752E
Cause: It works tape cutter, being connected with the multitude time sending by the feeder
but it doesn't work normally.
The sensor of the end of the tape cutter forward movement doesn't ON during automatic operation.
Remedy: During multitude time sending execution, confirm that the tape cutter cylinder works.
When this error occurs though the cylinder is working, adjust a sensor of the end of the forward
movement and a sensor of the end of the backward movement.
This error occurs when the automatic operation starts. In case of being, adjust a sensor of the end of the
forward movement.
------------------------------
Code: 12054040
Display:
Used by: GP551,GP6
Cause: Mask reception was not completed within the specified time.
Remedy: Check that the mask reception cylinder and sensors work correctly, and check that no objects
are interfering with the movement of the cylinder. If there are, remove the objects. Otherwise, adjust or
replace the cylinder.
------------------------------
Code: 12054041
Display: 周期异常 印刷压力响应
Used by: GSP5,GP2,GP3,GP551,GP6,GPX,NXTP
Cause: 不能够施加所设定的印刷压力下限值以上的印刷压力。 最大压和最小压都没有达到设定的印刷压力。 (GPX)
Remedy: 请确认印刷压力测定用放大器中是否正确地设定了印刷压力。可认为是气源进口压低于印刷压力下限值的设
定。请将印刷压力的设定值变更为合适的值。 存在刮刀没有到达钢板的可能性。请确认刮刀的安装是否正常。(GPX)
<img src="$LKEY_ERRIMG_MC$/12054041.PNG">
------------------------------
Code: 12054042
Display: Pre-RQ rotation Error
Used by: CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Pre-RQ rotation could not be performed within the cycle time (Station 13).
Remedy: Check that the axis is not overloaded. Remove any objects that interfere with axis
movement.Check the cylinder's advance and retract sensors.
------------------------------
Code: 12054043
Display: "Tape feed cylinder alarm" (CP6)
Used by: CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The tape feed cylinder did not advance or retreat within the specified time.
Remedy: Perform an I/O check OUT operation to turn off cylinder stopper Y026, then make sure that the
cylinder moves forward and retracts when the cam handle is turned or when C-axis inching is performed.