FUJI错误代码查询.pdf - 第1168页
Cause: Fujitrax-Verifier has reported that production cannot continue because the low quantity limit has been reached. The parameter indicates the target slot number. Remedy: Resupply parts to the feeder that has reached…
Remedy: Reexecute the command, or cut and resupply power to the HT.
------------------------------
Code: 1801012E
Display: HT command trans. error
HT error: 1801012E
Used by: QP132
Cause: Command could not be transmitted to the HT.
Remedy: Cut and resupply power to the HT.
------------------------------
Code: 18010131
Display: None
Used by: QP132
Cause: Current status not suitable for data change.
Remedy: Ensure that parts supply changes have been enabled at Proper data item "88. Parts Supply".
Check the command.
------------------------------
Code: 18020004
Display: Fujitrax-Verifier DB error.
Used by:
Cause: An error has occurred at the Fujitrax-Verifier database.
Remedy: Perform maintenance on the Fujitrax-Verifier database.
------------------------------
Code: 18020007
Display: Fujitrax-Verifier no ID information.
Used by:
Cause: There is no feeder or part information.
The set feeder FIDL or the part's DID is not registered in the Fujitrax-Verifier database.
The parameter indicates the target slot number.
Remedy: Check that the feeder FIDL and the part DID for the slot indicating "No ID information" or
"Unchecked" (during changeover) are registered in the Fujitrax-Verifier database.
------------------------------
Code: 18020008
Display: Fujitrax-Verifier device comment mismatch.
Used by:
Cause: The part device comment does not match the one registered in Fujitrax-Verifier.
The parameter indicates the target slot number.
Remedy: Check the DID device comment of the part set at the target slot, and check the device comment
registered in Fujitrax-Verifier.
------------------------------
Code: 18020009
Display: Fujitrax-Verifier parts out.
Used by:
Cause: Fujitrax-Verifier has reported that there are insufficient parts to continue production (parts out
limit).
The parameter indicates the target slot number.
Remedy: Check the target slot and resupply parts as necessary.
If there are still parts available, check if the remaining parts count at Fujitrax-Verifier is down to 0.
------------------------------
Code: 18020015
Display: Fujitrax-Verifier parts limit.
Used by:
第 1167 页
Cause: Fujitrax-Verifier has reported that production cannot continue because the low quantity limit has
been reached.
The parameter indicates the target slot number.
Remedy: Resupply parts to the feeder that has reached the low quantity limit (indicated at the device
check screen).
------------------------------
Code: 18020016
Display: Fujitrax-Verifier splicing warning.
Used by:
Cause: Fujitrax-Verifier has reported that production cannot continue because of a splicing warning.
The parameter indicates the target slot number.
Remedy: Splice new parts to the feeder at the target slot.
------------------------------
Code: 18020024
Display: Changeover database error.
Used by:
Cause: An error has occurred at the Kitting Station changeover database.
Remedy: Perform maintenance on the Kitting Station changeover database.
------------------------------
Code: 18020025
Display: Changeover not initiated.
Used by:
Cause: Changeover preparations have not been carried out at the Kitting Station for the supply unit
specified at the Handy Terminal.
The parameter indicates the target unit number.
Remedy: Perform changeover preparations again at the Kitting Station, or carry out a device check again
at the machine.
------------------------------
Code: 18020026
Display: Changeover supply unit mismatch.
Used by:
Cause: The supply unit for which changeover preparations were carried out at the Kitting Station does
not match the unit specified at the Handy Terminal.
The parameter indicates the target unit number.
Remedy: Move the supply unit to the specified stage.
To continue operation, perform a device check again at the machine.
------------------------------
Code: 18020027
Display: Changeover incomplete.
Used by:
Cause: Changeover preparations for the supply unit specified at the Handy Terminal are not complete.
Remedy: Complete the device checks for any feeders for which verification is not completed at the device
check screen.
------------------------------
Code: 18020028
Display: Fujitrax-Verifier communications timeout.
Used by:
Cause: Communications with the KIT Server have timed out.
An error has occurred at the KIT Server, or communication between the KIT Server and the machine
has been cut.
Remedy: Check the KIT Server.
第 1168 页
------------------------------
Code: 18020029
Display: KIT Server communications not enabled.
Used by:
Cause: No communication has been established with the KIT Server.
The KIT Server may be off, or the network cabling may be disconnected.
Remedy: Check the KIT Server and the network cabling.
------------------------------
Code: 18020030
Display: Communication error
Used by:
Cause: An error occurred during communication with Fujitrax Verifier.
Remedy: Restart the KIT Server.
------------------------------
Code: 18020031
Display: Data format error
Used by:
Cause: The reported data format is incorrect.
Remedy: Load the correct data.
------------------------------
Code: 18020069
Display: HOST通信产生错误
Used by:
Cause: FujiTrax和客户端HOST没有建立通信。
Remedy: 请确认FujiTrax和客户端HOST的连接状态后重新开始操作。如果还是无法解决,请在收集追踪数据后与本
公司客服中心联系。
------------------------------
Code: 18020101
Display: Fujitrax Verifier vision processing error
Used by:
Cause: A vision processing error was reported by Fujitrax Verifier.
The parameter indicates the target slot number.
Remedy: Check the parts at the target slot and perform a device check at the machine or Fujitrax Verifier.
------------------------------
Code: 18020102
Display: Fujitrax Verifier pick-up error
Used by:
Cause: A pick-up error was reported by Fujitrax Verifier.
The parameter indicates the target slot number.
Remedy: Check the parts at the target slot and perform a device check at the machine or Fujitrax Verifier.
------------------------------
Code: 18020103
Display: Fujitrax System Error
Used by:
Cause: Due to transmission trouble with Fujitrax(KIT Server, FLP, etc), production cannot start.
Remedy: Confirm that KIT Server and FLP are operating correctly.
------------------------------
Code: 18020300
Display:
Used by:
Cause:
第 1169 页