FUJI错误代码查询.pdf - 第1549页
Code: 1D234019 Display: 1D234019(CP2,3) Used by: Cause: The lead width is more than 50% narrower than the input value. Remedy: Check the lead width. ------------------------------ Code: 1D238002 Display: Used by: Cause: …
Display: 1D234003
Used by:
Cause: Coarse location of the part was not successful.
Remedy: Check the camera, the camera focus, the vision processing board and the cables. Remove any
foreign objects which may be present.
------------------------------
Code: 1D234004
Display: 1D234004
Used by:
Cause: The leads cannot be found.
Remedy: Check the camera, the camera focus, the vision processing board and the cables. Remove any
foreign objects which may be present.
------------------------------
Code: 1D234005
Display: 1D234005
Used by:
Cause: The x dimension of the part is more than 20% longer than the input value.
Remedy: Check the length of the part's x dimension.
------------------------------
Code: 1D234006
Display: 1D234006
Used by:
Cause: The x dimension of the part is too long.
Remedy: Check the length of the part's x dimension.
------------------------------
Code: 1D234007
Display: 1D234007(CP2,3)
Used by:
Cause: The length in the y direction is too long. The length is more than 50% longer than the input
value.
Remedy: Check the length of the part.
------------------------------
Code: 1D234008
Display: 1D234008(CP2,3)
Used by:
Cause: The length in the y direction is too short. The length is more than 50% shorter than the input
value.
Remedy: Check the length of the part.
------------------------------
Code: 1D234010
Display: 1D234010(CP2,3)
Used by:
Cause: The leads are too long.
Remedy: Check the lead length.
------------------------------
Code: 1D234018
Display: 1D234018(CP2,3)
Used by:
Cause: The lead width is more than 50% wider than the input value.
Remedy: Check the lead width.
------------------------------
第 1548 页
Code: 1D234019
Display: 1D234019(CP2,3)
Used by:
Cause: The lead width is more than 50% narrower than the input value.
Remedy: Check the lead width.
------------------------------
Code: 1D238002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D238100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D238110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D238111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D238112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D238113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D238114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D238115
第 1549 页
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D238120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D238121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D238122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D238123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
Remedy: Specify Qty_3.
------------------------------
Code: 1D2382??
Display:
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D2383??
Display:
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D2384??
Display:
Used by:
Cause: The body is too long in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D2385??
第 1550 页