time.Something interfered with the movement of the axis. Remedy: Check the load on the servo axis.Check the motor, servo amp connectors and wiring. Remove any obstacles to movement. ------------------------------ Code: 1…

100%1 / 5282
------------------------------
Code: 1205202A
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 1205202B
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 1205202C
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 1205202D
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 1205202F
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 12052030
Display:
Used by: GSP5
Cause: An MX axis cycle stop has occurred. The servo axis could not reach its tarte in the specified time.
Something interfered with the movement of the axis.
Remedy: Check the load on the servo axis.Check the motor, servo amp connectors and wiring. Remove
any obstacles to movement.
------------------------------
Code: 12052031
Display:
Used by: GSP5
Cause: An MYL axis cycle stop has occurred. The servo axis could not reach its tarte in the specified
time.Something interfered with the movement of the axis.
Remedy: Check the load on the servo axis.Check the motor, servo amp connectors and wiring. Remove
any obstacles to movement.
------------------------------
Code: 12052032
Display:
Used by: GSP5
Cause: An MYR axis cycle stop has occurred. The servo axis could not reach its tarte in the specified
第 525 页
time.Something interfered with the movement of the axis.
Remedy: Check the load on the servo axis.Check the motor, servo amp connectors and wiring. Remove
any obstacles to movement.
------------------------------
Code: 12052033
Display: Cycle Alarm SERVO SS
Used by: QP132
Cause: An SS servo axis cycle alarm has occurred. The servo axis did not reach the intended value within
the scheduled amount of time. Or there was something causing interference with the axis.
Remedy: Make sure that the servo is not overloaded. Check the connectors and wiring of the motor and
servo amp. Inspect the servo amp. Remove any objects that may be interfering with the axis.
------------------------------
Code: 12052034
Display: Cycle Alarm SERVO MX
Used by: QP132
Cause: An MX servo axis cycle alarm has occurred. The servo axis did not reach the intended value
within the scheduled amount of time. Or there was something causing interference with the axis.
Remedy: Make sure that the servo is not overloaded. Check the connectors and wiring of the motor and
servo amp. Inspect the servo amp. Remove any objects that may be interfering with the axis.
------------------------------
Code: 12052035
Display: Cycle Alarm SERVO MY
Used by: QP132
Cause: An MY servo axis cycle alarm has occurred. The servo axis did not reach the intended value
within the scheduled amount of time. Or there was something causing interference with the axis.
Remedy: Make sure that the servo is not overloaded. Check the connectors and wiring of the motor and
servo amp. Inspect the servo amp. Remove any objects that may be interfering with the axis.
------------------------------
Code: 12052036
Display: Cycle Alarm SERVO PI
Used by: QP132
Cause: A PI servo axis cycle alarm has occurred.The servo axis did not reach the intended value within
the scheduled amount of time. Or there was something causing interference with the axis.
Remedy: Make sure that the servo is not overloaded. Check the connectors and wiring of the motor and
servo amp. Inspect the servo amp. Remove any objects that may be interfering with the axis.
------------------------------
Code: 12052037
Display: Cycle Alarm SERVO PO
Used by: QP132
Cause: A PO servo axis cycle alarm has occurred.The servo axis did not reach the intended value within
the scheduled amount of time. Or there was something causing interference with the axis.
Remedy: Make sure that the servo is not overloaded. Check the connectors and wiring of the motor and
servo amp. Inspect the servo amp. Remove any objects that may be interfering with the axis.
------------------------------
Code: 12052038
Display: Cycle Alarm SERVO F
Used by:
Cause: An F servo axis cycle alarm has occurred.The servo axis did not reach the intended value within
the scheduled amount of time. Or there was something causing interference with the axis.
Remedy: Make sure that the servo is not overloaded. Check the connectors and wiring of the motor and
servo amp. Inspect the servo amp. Remove any objects that may be interfering with the axis.
第 526 页
------------------------------
Code: 12052039
Display: "UP Elevator UP/DOWN timeout"
Used by: CP652C
Cause: The UP elevator did not arrive at the upper (or lower) limit within the specified time after an
instruction to move up (or down) was issued. This error will also occur if the lower deceleration position
sensor is on when the elevator has arrived at the upper limit, or if the upper deceleration position sensor
is on when the elevator has arrived at the lower limit.
Remedy: If the elevator has arrived at the upper (or lower) limit, make sure that the upper (or lower) limit
sensor and the upper (or lower) deceleration position sensor are functioning normally. When the elevator
is moving up, the elevator upper limit and upper deceleration position sensors (X082 and X092) should be
off and the lower deceleration position sensor (X093) should be on. When it ismoving down, the lower
limit and lower deceleration position sensors (X083 and X093) should be off and the up er deceleration
position sensor (X092) should be on.
------------------------------
Code: 1205203A
Display: "UP Elevator Interlock ON"
Used by: CP652C
Cause: Either UP elevator pallet passage check sensor 1 (on the IN position side) or UP elevator pallet
passage check sensor 2 (on the PPS6 side) was tripped while the UP elevator was operating.
Remedy: Make sure that nothing is obstructing UP elevator operation. If there is no obstruction, perform
an I/O check to confirm input from the UP elevator pallet passage check sensors (X085 and X086,
respectively) and adjust as necessary.
------------------------------
Code: 1205203B
Display: "DOWN Elevator UP/DOWN timeout"
Used by: CP652C
Cause: The DOWN elevator did not arrive at the upper (or lower) limit within the specified time after an
instruction to move up (or down) was sent. This error will also occur if the lower deceleration position
sensor is on when the elevator has arrived at the upper limit, or if the upper deceleration position sensor
is on when the elevator has arrived at the lower limit.
Remedy: If the elevator has arrived at the upper (or lower) limit, make sure that the upper (or lower) limit
sensor and the upper (or lower) deceleration position sensor are functioning normally. When the elevator
is moving up, the elevator upper limit and upper deceleration position sensors (X0A2 and X09A) should be
off and the lower deceleration position sensor (X0AB) should be on. When it ismoving down, the lower
limit and lower deceleration position sensors (X0A3 and X0AB) should be off and the up er deceleration
position sensor (X0AA) should be on.
------------------------------
Code: 1205203C
Display: "DOWN Elevator Interlock ON"
Used by: CP652C
Cause: The DOWN elevator pallet passage check sensor was tripped while the UP elevator was operating.
Remedy: Make sure that nothing is obstructing DOWN elevator operation. If there is no obstruction,
perform an I/O check to confirm input from the DOWN elevator pallet passage check sensor (X0A5)
andadjust as necessary.
------------------------------
Code: 1205203D
Display: "Cycle Alarm DF or DR"
Used by: CP652C
Cause: Servo axis DF or DR did not reach the target position within the expected time. This error may be
caused by interference from another object, an excessive load, or an abnormality in a servo system circuit.