FUJI错误代码查询.pdf - 第721页

Remedy: Since production cannot be continued in such cases, either use the [SKIP] command to eject the board, or execute flush-out operation. This error should not normally occur on the QP2. -----------------------------…

100%1 / 5282
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12070?23
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Z Axis Not at Origin" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The Z-axis is not at the origin position.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Use inching or another method to return the Z-axis to the origin position, then restart. If the
machine has a sensor at the Z-axis origin position, check the sensor input.
------------------------------
Code: 12070?24
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Fiducial Mark Data" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The program does not contain sufficient fiducial marks to allow component placement.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the fiducial marks and the mark sequences in the program that caused the error, then
retransmit the program.
------------------------------
Code: 12070?25
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Check Sum Data Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command contains erroneous checksum data.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?26
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Board Attribute Data" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine does not contain any attribute data for a board. When a board's fiducial marks are
read at the mark reading station, a pallet data table is created that contains information such as mark
deviation amounts and block skip data. Although this data is supposed to be assured until the pallet is
ejected, the table corresponding to the pallet in question could not be found. This error may also occur
during index operation in a mode other than automatic mode, or as the result of a QP1 firmw re
malfunction.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
第 720 页
Remedy: Since production cannot be continued in such cases, either use the [SKIP] command to eject the
board, or execute flush-out operation. This error should not normally occur on the QP2.
------------------------------
Code: 12070?27
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Insuff Attrib Data Area" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: There is insufficient area for board attribute data.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?28
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Start before Index Comp" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A start instruction was received before index completion.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?29
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"VP Position NG" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A vision processing command was received even though the object to be processed is not at the
camera position.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?2A
Display: "ICM(PMC?,SCU?) Error Code:********"
"Parts removal error"
Used by: QP203
Cause: Failed to remove the spring clip correctly.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check to see if the spring clip has been dropped on the FOL carrier. Check to ensure the
mechanical chuck and the parts confirmation sensor (CLIP DETECT) are operating correctly.
------------------------------
Code: 12070?2B
Display: "ICM(PMC?,SCU?) Error Code:********"
第 721 页
"Parts release error"
Used by: QP203
Cause: The placing head has returned without placing the heat spreader or the spring clip.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove the part(s) which caused the error. Check to ensure the mechanical chuck and the
parts confirmation sensor (CLIP DETECT) are operating correctly.
------------------------------
Code: 12070?2C
Display: "ICM(PMC?,SCU?) Error Code:********"
"Clip pickup confirm. error"
Used by: QP203
Cause: Failed to pick-up the spring clip correctly.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check to see if the spring clip has been dropped on the supply tray. Check to ensure the
mechanical chuck and the parts confirmation sensor (CLIP DETECT) are operating correctly.
------------------------------
Code: 12070?2D
Display: "ICM(PMC?,SCU?) Error Code:********"
"Clip plmt confirm. error"
Used by: QP203
Cause: Failed to attach the spring clip.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check to ensure the spring clip has been attached correctly. If there is a problem, remove the
heat spreader and spring clip from the placing head, then check the placement coordinates. If the spring
clip is attached correctly, check that the block number settings in the recipe match the block number at
the placement target. Check to ensure the spring clip attachment confirmation sensors (CLIP CHK1 to 10)
are operating correctly.
------------------------------
Code: 12070?2E
Display: "ICM(PMC?,SCU?) Error Code:********"
"Parts at placement position"
Used by: QP203
Cause: Placement was not possible because the target position is already occupied.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the position for which the error occurred. If the position is occupied, change your
sequence data in the recipe. If the position is not occupied, check to ensure the spring clip attachment
confirmation sensors (CLIP CHK1 to 10) are operating correctly.
------------------------------
Code: 12070?2F
Display: "ICM(PMC?,SCU?) Error Code:********"
"Parts could not be rejected"
Used by: QP203
Cause: Failed to dump parts.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove any parts on the placing head. Also, check that there are no errors with the mechanical
chuck or the parts confirmation sensor (CLIP DETECT).
------------------------------
Code: 12070?30
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Not at Origin Position" (QP2)
PM?? ERROR Code:******** (QP132)
第 722 页