Code: 2306003E
Display: The stage/slot numbers for the following feeder setup in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 100, and when stage 2 is specified, the slot
number input range is 1 to 400.
------------------------------
Code: 2306003F
Display: The stage number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The stage number input range is 1 to 2.
------------------------------
Code: 23060040
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. When the stage number value is 1, the slot number input range is 1 to 100. When the stage
number value is 2, the slot number input range is 1 to 400.
------------------------------
Code: 23060042
Display: Even if nozzle kinds are combined so that the maximum diameter nozzles are not used, there are
too many nozzle kinds to fit in the folder.
Used by:
Cause: When using automatic nozzle arrangement, the required number of nozzles exceed the number in
the nozzle folder.
Remedy: The program file is incorrect. Check the Nozzle Spec. file, or check the Minimum Nozzle Diameter
(PARTS/ENVDT/XP341ENVDT-/PENMI) and Maximum Nozzle Diameter (PARTS/ENVDT/XP341ENVDT-
/PENMA) settings in the part data.
------------------------------
Code: 23060044
Display: There is no nozzle suitable for the part.
Used by:
Cause: There is no suitable nozzle available in the nozzle folder for the part.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle arrangement] method. If using [Automatic Optimized
Nozzle Arrangement], check the Nozzle Spec. file, or check the Minimum Nozzle Diameter
(PARTS/ENVDT/XP341ENVDT-/PENMI) and Maximum Nozzle Diameter (PARTS/ENVDT/XP341ENVDT-
/PENMA) settings in the part data.
------------------------------
Code: 23060045
Display: There is no nozzle of the name specified for the parts.
Used by:
Cause: In the nozzle folder, there is no nozzle of the name specified for the parts.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
第 2168 页
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle Arrangement] method. If using [Automatic Optimized
Nozzle Arrangement], check the Nozzle Spec. file, or check the Nozzle Name
(PARTS/ENVDT/XP341ENVDT-/PENNZN) in the part data.
------------------------------
Code: 23060047
Display: The Alt. Feeder number must be set to a different slot. Set the Alt. Feeder to 0?
Used by:
Cause: A Alt. Feeder number has been set for the same slot.
Remedy: In the program file's Feeder Setup settings, and change the Alt. Feeder number
(PROGRAM/DEVICE+/GUTNSLTN) to 0 (No Alt. Feeder) or to another slot number.
------------------------------
Code: 23060048
Display: A Alt. Feeder is duplicated, or two or more first slots (reference slot) have been specified for the
same alternate feeder loop. The Alt. Feeder settings will be deleted.
Used by:
Cause: Two or more alternate feeder loops may be overlapping.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2306004A
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a loop did not exist. The Alt. Feeder setting is zero.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2306004B
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a non-existent Alt. Feeder setting was found.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2306004C
Display: Nozzle name is not specified. Assume as a standard nozzle?
Used by:
Cause: In the Nozzle folder information file, the Nozzle name is not specified for "GNANAM".
Remedy: When [Yes] is selected, standard Nozzle name is specified according to the diameter. When [No]
is selected, no Nozzle is specified to the Nozzle folder.
------------------------------
Code: 230600A1
Display: The source program is already in an optimized condition. It is not possible to further optimize the
source program.
Used by:
Cause: The post-optimized theoretical cycle time is slower than the pre-optimized time, however, source
program sequence or feeder setup problems have been fixed.
Remedy: It may be possible to achieve a better cycle time result by changing the optimization conditions,
if production constraints allow.
第 2169 页
------------------------------
Code: 230600A3
Display: Optimization cannot be performed if there are less than two active fiducial marks.
Used by:
Cause: Optimization cannot be performed for programs containing less than two active fiducial marks,
including skipped marks.
Remedy: Add two or more active fiducial mark sequences to the program.
------------------------------
Code: 230600A4
Display: Optimization cannot be performed because no valid placement sequences exist.
Used by:
Cause: Optimization cannot be performed because all placement sequences are skipped.
Remedy: The program must contain at least one placement sequence that is not to be skipped.
------------------------------
Code: 2306010C
Display: Tray part(s) cannot be loaded on the XP-341E.
Used by:
Cause: Package Type(PARTS/PACKCLS-/PPCMNPT) is 0*.
Remedy: The Package Type setting in the part data is incorrect. Check and correct the setting.
------------------------------
Code: 2306010E
Display: Dual Tape Feeder(s) cannot be loaded on the XP-341E.
Used by:
Cause: Package Type(PARTS/PACKCLS-/PPCMNPT) is 8*.
Remedy: The Package Type setting in the part data is incorrect. Check and correct the setting.
------------------------------
Code: 23078003
Display: Unregistered Tape Width.A feeder cannot be selected.
Used by:
Cause: <XP*42>Cannot optimize because feeder width is unknown.A registered Tape Width must be used
so that a feeder can be selected.
Remedy: <XP142>If Packaging Type is not "2:32mm Adhesive",set the tape width to "8","12","16","24",or
"32".
<XP242>If Packaging Type is not "0:Tray","2:32mm Adhesive","4:Stick Feeder"or "9:Grooved Stick
Feeder",set The Tape Width to "8","12","16","24","32","44","56","72",or "88".
------------------------------
Code: 23078005
Display: The stage-slot number is not defined.
Used by:
Cause: XP*42>No setting data exists for the stage-slot number specified in the sequence data.
Remedy: <XP*42>Either specify settings for the stage-slot number in the feeder setup data,or specify a
stage-slot number for which setting data already exists.
------------------------------
Code: 23078006
Display: The part data is not found.
Used by:
Cause: <XP*42>Data corresponding to the part number does not exist.
Remedy: <XP*42>Create the specified part number data,or specify an existing part number.
------------------------------
Code: 2307800E
Display: Feeders cannot be arranged.
第 2170 页