FUJI错误代码查询.pdf - 第198页

turn off the power and start again. ------------------------------ Code: 11075004 Display: L3 COP_CAL COM Used by: IP1,IP2,IP3 Cause: A command to the L3 board to start coplanarity calculations resulted in an internal pr…

100%1 / 5282
Used by:
Cause: The carrier dropped a part.
Remedy: Feed another part to the carrier.
------------------------------
Code: 11074430
Display:
Used by: IP2
Cause: Parts were not moved to the machine.
Remedy: Check the carrier.
------------------------------
Code: 11074440
Display: MTU Positioning Err
Used by: IP2
Cause: The tray movement command was not carried out correctly.
Remedy: Turn off the power at the IP2 and the MTU, and re-boot.
------------------------------
Code: 11074450
Display: MTU Error
Used by:
Cause: An error occurred at the MTU.
Remedy: Turn off the power at the IP2 and the MTU, and re-boot.
------------------------------
Code: 11075001
Display: L3 SCAN_S COM
Used by: IP1,IP2,IP3
Cause: Transmission (to the L3 board) of a command to start scanning resulted in an error, or a timeout
condition.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again.
------------------------------
Code: 11075002
Display: L3 SCAN_S PRC
Used by: IP1,IP2,IP3
Cause: A command to start scanning was sent to the L3 board, and an error was returned, or a timeout
condition occurred.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again.
------------------------------
Code: 11075003
Display: L3 SCAN_E COM
Used by: IP1,IP2,IP3
Cause: Transmission (to the L3 board) of a command to start scanning resulted in an error, or a timeout
condition. This may be due to one of the following causes: the L3 board baud rate is set below 9600
(timeout), not all the leads could be measured, or the encoder cable/sensor cable is not properly
connected.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. Check that the length of
the leads in 10.Lead_length_x and Lead_length_y in Vision_data are the same as the actual leads. Check
that the size entered in Body_size is the same as the actual body size. Make Coplanarity item 4.Y_offset
bigger so that the measurement is done farther from the tips of the leads. Check that the encoder cable is
properly connected to the CyberOptics board. Check that the sensor cable is properly connected to both
the sensor and the CyberOptics board. The cable should be connected to jumper 1. If the error recurs,
第 197 页
turn off the power and start again.
------------------------------
Code: 11075004
Display: L3 COP_CAL COM
Used by: IP1,IP2,IP3
Cause: A command to the L3 board to start coplanarity calculations resulted in an internal processing
error, or a timeout condition occurred. Remedy: If the L3 board baud rate is set below 9600, set it to
9600 or greater. If the error recurs, turn off the power and start again.
Remedy:
------------------------------
Code: 11075005
Display: L3 COP_CAL PRC
Used by: IP1,IP2,IP3
Cause: A command to start coplanarity calculations was sent to the L3 board, and an internal processing
error was returned, or a timeout condition occurred.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again. Check that the part has 2, 3 or 4 leaded sides. If the part has only one leaded
side, coplanarity calculations cannot be carried out.
------------------------------
Code: 11075006
Display: L3 ENC_RES SET
Used by: IP1,IP2,IP3
Cause: An error occurred when the machine tried to set the encoder resolution value for L3.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again.
------------------------------
Code: 11075007
Display: L3 ENG DATA
Used by: IP1,IP2,IP3
Cause: An error or timeout condition occurred when the machine attempted to call up engineering data
from the L3 board.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again.
------------------------------
Code: 11075008
Display: L3 Para SET
Used by: IP1,IP2,IP3
Cause: An error or timeout condition occurred when the machine attempted to set L3 parameters
(linearity tolerance or coplanarity tolerance).
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again.
------------------------------
Code: 11075009
Display: L3 SCAN_E PRC
Used by: IP1,IP2,IP3
Cause: Transmission (to the L3 board) of a command to stop scanning resulted in an error, or a timeout
condition. This may be due to one of the following causes: the L3 board baud rate is set below 9600
(timeout), not all the leads could be measured, or the encoder cable/sensor cable is not properly
connected.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. Check that the width and
length of the leads in 10.Lead_length_x and Lead_length_y in Vision_data are the same as the actual leads.
第 198 页
Check that the size entered in Body_size is the same as the actual body size. Make Coplanarity item
4.Y_offset bigger so that the measurement is done farther from the edge of the leads. Check that the
encoder cable is properly connected to the CyberOptics board. Check that the sensor cable is properly
connected to both the sensor and the CyberOptics board. The cable should be connected to jumper 1. If
the error recurs, turn off the power and start again.
------------------------------
Code: 1107500A
Display: LLL system is executing another command.
Used by: IP3
Cause: Another measurement command was executed while the LLL board was performing a coplanarity
check.
Remedy: Switch off the machine and then re-start it.
------------------------------
Code: 1107500B
Display: Leads do not exist on part being inspected.
Used by: IP3
Cause: There were no leads on the part on which the coplanarity check was performed.
Remedy: The coplanarity check cannot be performed on parts which have no leads. Check that the Part
data settings are correct.
------------------------------
Code: 11079?01
Display: RB Servo Error :9?01
Used by: GP551,GP6,QP132
Cause: Processing cannot be performed during an emergency stop.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: After releasing the emergency stop button, restart operation.
------------------------------
Code: 11079?02
Display: "RB Servo Error: 9?02"
Used by: GP551,GP6,QP132
Cause: A timeout occurred during communication with the RB servo unit.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: Restart processing after resetting. This error may also be caused by breaks in cables, or by
malfunctions of the communication board or the RB controller.
------------------------------
Code: 11079?03
Display: RB Servo Error :9?03
Used by: GP551,GP6,QP132
Cause: It is not possible to execute a new command while still executing another command.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: Press RESET and then restart operation.
------------------------------