FUJI错误代码查询.pdf - 第1203页
Display: 1CB01003 Used by: GL541 Cause: The jig cannot be found. Remedy: Check that the correct jig is being used. ------------------------------ Code: 1CB01004 Display: 1CB01004 Used by: GL541 Cause: The inclination of …
Display: 1CAF3005
Used by:
Cause: The defined lead elements do not match with the detected elements.
Remedy: Check the following items in element data.
帴Lead position
帴Lead center tolerance
帴Lead width
帴Lead width tolerance
帴Lead length
帴Lead length tolerance
------------------------------
Code: 1CAF3006
Display: 1CAF3006
Used by:
Cause: The number of detected leads differs from the number of leads specified in element data.
Remedy: Check the following part data items.
帴Vision height offset
帴No. of leads
帴Lead position
帴Lead center tolerance
帴Lead width
帴Lead width tolerance
帴Lead length
帴Lead length tolerance
------------------------------
Code: 1CAF3007
Display: 1CAF3007
Used by:
Cause: Failed to detect any leads.
Remedy: Ensure that the part pick-up position is not excessively out. If the pick-up position is okay,
check the following element data items.
帴Lead position
帴Lead center tolerance
帴Lead width
帴Lead width tolerance
帴Lead length
帴Lead length tolerance
------------------------------
Code: 1CB01001
Display: 1CB01001
Used by: GL541
Cause: The fluorescent plate cannot be found.
Remedy: Check the jig. Confirm that the fluorescent plate is being lit by checking the acquired image.
------------------------------
Code: 1CB01002
Display: 1CB01002
Used by: GL541
Cause: The fluorescent plate is dirty.
Remedy: Clean the fluorescent plate or change the nozzle.
------------------------------
Code: 1CB01003
第 1202 页
Display: 1CB01003
Used by: GL541
Cause: The jig cannot be found.
Remedy: Check that the correct jig is being used.
------------------------------
Code: 1CB01004
Display: 1CB01004
Used by: GL541
Cause: The inclination of the jig could not be measured.
Remedy: Check that the correct jig is being used.
------------------------------
Code: 1CB01005
Display: 1CB01005
Used by: GL541
Cause: The jig is tilted more than 5 deg..
Remedy: Correct the angle of the jig.
------------------------------
Code: 1CB01006
Display: 1CB01006
Used by: GL541
Cause: The jig edge could not be found.
Remedy: Check that the jig is fully illuminated in the acquired image.
------------------------------
Code: 1CB01101
Display: 1CB01101
Used by: GL541
Cause: The camera type specification is incorrect.
Remedy: Specify the correct camera type.
------------------------------
Code: 1CB01102
Display: 1CB01102
Used by: NP133
Cause: The entered parameter is outside the permissible range.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB02001
Display: 1CB02001
Used by: GL541
Cause: The fluorescent plate could not be found.
Remedy: Check the nozzle. Confirm that the fluorescent plate is being lit by checking the acquired image.
------------------------------
Code: 1CB02002
Display: 1CB02002
Used by: GL541
Cause: The fluorescent plate is dirty.
Remedy: Clean the fluorescent plate or change the nozzle.
------------------------------
Code: 1CB02003
Display: 1CB02003
Used by: GL541
Cause: The nozzle could not be found.
第 1203 页
Remedy: Check the nozzle. Check that there are no foreign objects in the acquired image.
------------------------------
Code: 1CB02004
Display: 1CB02004
Used by: GL541
Cause: The inclination of the nozzle could not be measured.
Remedy: Check the nozzle. Check that there are no foreign objects in the acquired image.
------------------------------
Code: 1CB02005
Display: 1CB02005
Used by: GL541
Cause: Not presently supported.
Remedy:
------------------------------
Code: 1CB02006
Display: 1CB02006
Used by: GL541
Cause: The nozzle search was not successful.
Remedy: Check that the correct nozzle is being used.
------------------------------
Code: 1CB02201
Display: 1CB02201
Used by: GL541
Cause: The nozzle type specification is incorrect.
Remedy: Specify the correct nozzle type.
------------------------------
Code: 1CB02202
Display: 1CB02202
Used by: GL541
Cause: The nozzle size specification is incorrect.
Remedy: Specify the correct nozzle size.
------------------------------
Code: 1CB02203
Display: 1CB02203
Used by: NP133
Cause: The entered parameter is outside the permissible range.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB03001
Display: 1CB03001
Used by: GL541
Cause: The specified mark size is too small.
Remedy: The minimum mark size is 0.5 mm. Check that the mark data settings in the production
program are correct. If they ARE correct, use a different mark.
------------------------------
Code: 1CB03002
Display: 1CB03002
Used by: GL541
Cause: The specified mark size is too large.
Remedy: The maximum mark size is 3.5 mm. Check that there are no errors in the production program's
mark data. If the production program is correct, use another mark.