------------------------------ Code: 1D030010 Display: 0016 Used by: Cause: The part is too short in the Y direction. Remedy: Check that the nozzle is not dirty, that there are no foreign particles on the part, and that …
Used by:
Cause: Part data's Body-Size is 0.
Remedy: Check Part data.
------------------------------
Code: 1D030005
Display: 0005
Used by:
Cause: Part data's lead width is 0.
Remedy: Check Part data.
------------------------------
Code: 1D030006
Display: 0006
Used by:
Cause: Part data's Pitch is 0.
Remedy: Check Part data.
------------------------------
Code: 1D030007
Display:
Used by:
Cause: The part's upper or lower area cannot be found. The part is too long in the Y direction.
Remedy: Check the picking conditions. Check the part size.
------------------------------
Code: 1D030008
Display:
Used by:
Cause: The part is too short in the Y direction. The part's angle of tilt is too large.
Remedy: Check the part size. Check the picking conditions.
------------------------------
Code: 1D03000A
Display: 0010
Used by:
Cause: There is no bright area on the right.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D03000B
Display: 0012
Used by:
Cause: The unevenness on the right is too large.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D03000D
Display: 0014
Used by:
Cause: The part shape is not what was expected. Vision processing cannot take a good image.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D03000F
Display: 0015
Used by:
Cause: The part shape is not what was expected. Vision processing cannot take a good image.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
第 1263 页
------------------------------
Code: 1D030010
Display: 0016
Used by:
Cause: The part is too short in the Y direction.
Remedy: Check that the nozzle is not dirty, that there are no foreign particles on the part, and that the
correct part is being analyzed.
------------------------------
Code: 1D030011
Display: 0017
Used by:
Cause: The part is too long in the Y direction.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D030012
Display: 0018
Used by:
Cause: The part shape is not what was expected. Vision processing cannot take a good image.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D030013
Display: 0019
Used by:
Cause: The part shape is not what was expected. Vision processing cannot take a good image.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D030014
Display: 0020
Used by:
Cause: The upper right hand corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D030015
Display: 0021
Used by:
Cause: The lower right hand corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D030016
Display:
Used by:
Cause: The upper area lead cannot be found. The tilt of the part was too large.
Remedy: Check the shape of the part. Check that the part is being picked properly.
------------------------------
Code: 1D030017
Display:
Used by:
Cause: The lower area lead cannot be found. The tilt of the part was too large.
Remedy: Check the shape of the part. Check that the part is being picked properly.
------------------------------
Code: 1D030080
第 1264 页
Display:
Used by:
Cause: A level surface cannot be found. The tilt of the part was too large.
Remedy: Check the shape of the part. Check that the part is being picked properly.
------------------------------
Code: 1D030081
Display:
Used by:
Cause: A level surface cannot be found. The tilt of the part was too large.
Remedy: Check the shape of the part. Check that the part is being picked properly.
------------------------------
Code: 1D030082
Display:
Used by:
Cause: A level surface cannot be found. The tilt of the part was too large.
Remedy: Check the shape of the part. Check that the part is being picked properly.
------------------------------
Code: 1D030083
Display:
Used by:
Cause: A correct image cannot be taken. The upper and lower parts of the part are too uneven. There is
foreign matter on the part.
Remedy: Check the camera, vision processing board, cable and focus. Remove foreign matter from the
part.
------------------------------
Code: 1D038002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D038100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D038110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D038111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------