FUJI错误代码查询.pdf - 第166页
Remedy: Measure the pulse values from the center of the mark camera to the center of the 1st pin check camera(#1). Input this value into 111.IC_Mark_Camera_Pos.X for the FLT and 112.IC_Mark1_Camera_Pos.X for the FIP3. --…
3 = Tamura VPS Reflow oven.
4 = Koki Reflow oven.
5 = Senju Reflow Oven.
Do not use
------------------------------
Code: 11022900
Display:
Used by: IP3
Cause: Origin_Position_X has no value specified.
Remedy: Input an appropriate value in Proper data's 100.Origin_Position_X item.
------------------------------
Code: 11022901
Display:
Used by: IP3
Cause: Origin Position Y has not been specified.
Remedy: Specify a value in Proper data item 100.Origin_Position_Y.
------------------------------
Code: 11022902
Display:
Used by: IP3
Cause: Nozzle position X1 has no data value specified.
Remedy: Input the offset pulse value from the mark camera center to nozzle 1 in the X direction. For the
FLT, input a value in 102.Nozzle_Position_X and for the IP3, input a value in 102.Nozzle1_Position_X.
------------------------------
Code: 11022903
Display:
Used by: IP3
Cause: Nozzle position X2 (offset pulse) has no data entered.
Remedy: Input the offset pulse value from the mark camera center to nozzle 2 in the X direction. For the
IP3, input a value in 103.Nozzle2_Position_X.
------------------------------
Code: 11022904
Display:
Used by: IP3
Cause: The vision processing camera 1 position has not been specified.
Remedy: Measure the pulse values from the center of the mark camera to the center of vision processing
camera 1. Input this value into 103.Camera1_Position_X for the FLT and 104.Camera1_Position_X for the
FIP3.
------------------------------
Code: 11022905
Display:
Used by: IP3
Cause: The vision processing camera 2 position has not been specified.
Remedy: Measure the pulse values from the center of the mark camera to the center of vision processing
camera 2. Input this value into 104.Camera2_Position_X for the FLT and 105.Camera2_Position_X for the
FIP3.
------------------------------
Code: 11022906
Display:
Used by:
Cause: The 1st pin check camera (#1) position has not been specified.
第 165 页
Remedy: Measure the pulse values from the center of the mark camera to the center of the 1st pin check
camera(#1). Input this value into 111.IC_Mark_Camera_Pos.X for the FLT and
112.IC_Mark1_Camera_Pos.X for the FIP3.
------------------------------
Code: 11022907
Display:
Used by:
Cause: The 1st pin check camera (#2) position has not been specified.
Remedy: Measure the pulse values from the center of the mark camera to the center of the 1st pin check
camera(#2). Input this value into 114.IC_Mark2_Camera_Pos.X for the FIP3.
------------------------------
Code: 11022908
Display:
Used by: IP3
Cause: No reflow position value has been input.
Remedy: Measure the pulse value obtained from measuring the distance from the placing nozzle (after
zero setting) to the center of rotation of the reflow head. Input this into Proper data item
113.Reflow_Position_X for the FLT.
------------------------------
Code: 11022909
Display:
Used by: IP3
Cause: The distance from placing nozzle 1 to the board surface has not been specified.
Remedy: Specify the pulse count of the distance from the position of nozzle 1 (after zero setting) to the
surface of the board. Input this into Proper data item 123.Origin_Position_Z for the FLT and
130.Origin_Position_Z1 for the FIP3.
------------------------------
Code: 1102290A
Display:
Used by: IP3
Cause: The distance from placing nozzle 2 to the board surface has not been specified.
Remedy: Specify the pulse count of the distance from the position of nozzle 1 (after zero setting) to the
surface of the board. Input this into Proper data item 131.Origin_Position_Z1 for the FIP3.
------------------------------
Code: 1102290B
Display:
Used by:
Cause: The carrier position Z1 position has not been specified even though carrier 1 is supposed to pick
parts from MTU1.
Remedy: Input the pulse count of the Z1 axis at the picking position of carrier 1. For the FLT, use
124.Carrier_Position_Z. For the FIP3, use 132.Carrier_Position_Z1.
------------------------------
Code: 1102290C
Display:
Used by:
Cause: The carrier position Z2 position has not been specified even though carrier 2 is supposed to pick
parts from MTU2.
Remedy: Input the pulse count of the Z2 axis at the picking position of carrier 2. For the FIP3, use
132.Carrier_Position_Z1.
------------------------------
Code: 1102290D
第 166 页
Display:
Used by: IP3
Cause: The carrier position Z1 position has not been specified even though carrier 1 is supposed to pick
parts from MFU1.
Remedy: Input the pulse count of the Z1 axis at the picking position of carrier 1. For the FLT, use
125.MFU1_Position_Z. For the FIP3, use 134.MFU1_Position_Z1.
------------------------------
Code: 1102290E
Display:
Used by: IP3
Cause: The carrier position Z2 position has not been specified even though carrier 2 is supposed to pick
parts from MFU2.
Remedy: Input the pulse count of the Z2 axis at the picking position of carrier 2. For the FLT, use
126.MFU2_Position_Z. For the FIP3, use 132.MFU2_Position_Z1.
------------------------------
Code: 1102290F
Display:
Used by: IP3
Cause: The nozzle change position has not been input for nozzle 1 even though that nozzle is to be
changed.
Remedy: Input the Z1 axis nozzle change position into Proper data
127.Nozzle_change_Pos.Z for the FLT and
136.Nozzle_change_Pos.Z1 for the FIP3.
------------------------------
Code: 11022910
Display:
Used by: IP3
Cause: The nozzle change position has not been input for nozzle 2 even though that nozzle is to be
changed.
Remedy: Input the Z1 axis nozzle change position into Proper data
137.Nozzle_change_Pos.Z2 for the FIP3.
------------------------------
Code: 11022911
Display:
Used by: IP3
Cause: The zero set position in the Q1 axis has not been input for nozzle 1.
Remedy: Input the Q1 axis zero set position into Proper data
128.Origin_Position_Q for the FLT and
138.Origin_Position_Q1 for the FIP3.
------------------------------
Code: 11022912
Display:
Used by: IP3
Cause: The zero set position in the Q2 axis has not been input.
Remedy: Input the Q2 axis zero set position into Proper data item
139.Origin_Position_Q2 for the FIP3.
------------------------------
Code: 11022913
Display:
Used by: IP3
Cause: The X2 axis plus movement range has not been specified.
第 167 页