Remedy: Execute the recovery command. ------------------------------ Code: 12020204 Display: TPU SHUTTLE ERROR Used by: IP2,IP3 Cause: The shuttle does not work properly. Remedy: Operate the equipment in manual operation…
------------------------------
Code: 12020106
Display: Plt Clear Off To PPS Error
Used by: CP5
Cause: A request was made from PCM to PPS to unload pallets. The lower conveyor of the PPS was not
empty.
Remedy: Remove the pallet from the PPS lower conveyor.
------------------------------
Code: 12020107
Display: Check PCM R_Conveyor
Used by: CP5
Cause: An error was received from the PCM return conveyor.
Remedy: Check the PCM error display and remove the cause of the error.
------------------------------
Code: 12020108
Display:
Used by: CP5
Cause: The PCM is in manual operation, or the in and out elevator pallet arrived sensor or the pallet
arrived sensor between the out elevator and the PPS is OFF. The permission signal from the PPS to the
out elevator (with a PPS) is OFF.
Remedy: Get the PCM out of manual operation. Check the sensors.
------------------------------
Code: 12020109
Display: Desired Pallet is Not Found
Used by: CP652C
Cause: The PCM or PPS pallets were circulated and a search for the desired pallet was carried out, but
the pallet was not in the machine.
Remedy: Load the pallet to be used in production into the machine.
------------------------------
Code: 12020200
Display: TPU SEQUENCER ERROR
Used by: IP2,IP3
Cause: The digital controller is damaged or the battery is dead.
Remedy: Operate the equipment in manual operation. If it does not work normally, contact Fuji.
------------------------------
Code: 12020201
Display: TPU DEVICE No. ERROR
Used by: IP2,IP3
Cause: An incorrect magazine number was specified.
Remedy: Check the production program.
------------------------------
Code: 12020202
Display: TPU CYCLE NG
Used by: IP2,IP3
Cause: The TPU cycle could not finish.
Remedy: Operate the equipment in manual operation. If it does not work normally, contact Fuji.
------------------------------
Code: 12020203
Display: TPU PICK UP ERROR
Used by: IP2,IP3
Cause: The machine failed to pick parts.
第 290 页
Remedy: Execute the recovery command.
------------------------------
Code: 12020204
Display: TPU SHUTTLE ERROR
Used by: IP2,IP3
Cause: The shuttle does not work properly.
Remedy: Operate the equipment in manual operation. If it does not work normally, contact Fuji.
------------------------------
Code: 12020205
Display: TPU FORMING ERROR
Used by: IP2,IP3
Cause: The cut-and-form mechanism does not work properly.
Remedy: Operate the equipment in manual operation. If it does not work normally, contact Fuji.
------------------------------
Code: 12020206
Display: TPU SUPPLY ERROR
Used by: IP2,IP3
Cause: The TPU part supplier does not work properly.
Remedy: Operate the equipment in manual operation. Also, check the supplier at the I/O board.
------------------------------
Code: 12020207
Display: TPU ORIGINAL POSITION ERROR
Used by: IP2,IP3
Cause: When the TPU was started, the shuttle or the cut-and-form mechanism was not in the original
position.
Remedy: Return these parts to the origin position in manual operation.
------------------------------
Code: 12020208
Display: TPU MANUAL MODE ERROR
Used by: IP2,IP3
Cause: The TPU is in manual operation.
Remedy: Perform production in automatic operation.
------------------------------
Code: 12020209
Display: TPU EMERGENCY
Used by: IP2,IP3
Cause: The TPU has been subject to an emergency stop.
Remedy: Release the Emergency Stop button, or check for the cause at the I/O board.
------------------------------
Code: 1202020A
Display:
Used by: IP2,IP3
Cause: A parameter was specified incorrectly during startup of the TPU.
Remedy: Check the production program.
------------------------------
Code: 1202020B
Display:
Used by: IP3
Cause: A part supply cycle could not be completed.
Remedy: Check the I/O board at the machine.
------------------------------
第 291 页
Code: 1202020C
Display:
Used by: IP2,IP3
Cause: There was a TPU communication alarm.
Remedy: Check the I/O board at the machine.
------------------------------
Code: 1202020D
Display:
Used by: IP2,IP3
Cause: The TPU is out of parts.
Remedy: Supply parts to the TPU. Check the part sensors at the input section of the I/O board.
------------------------------
Code: 1202020E
Display:
Used by: IP2,IP3
Cause: There was a TPU communication alarm.
Remedy: Check the I/O board at the machine.
------------------------------
Code: 12020300
Display:
Used by: GSP5
Cause: An alarm was issued from the solder supplier.
Remedy: This is probably a solder supplier amp error. Check the solder supplier manual for more details.
------------------------------
Code: 12020301
Display:
Used by: GSP5
Cause: Too much amperage (0.7 amps or over) was flowing through the motor.
Remedy: The outer tubing is loose or the spiral shaft is not set in the garage. Check these items.
------------------------------
Code: 12020302
Display:
Used by: GSP5
Cause: Not enough amperage is flowing through the motor.
Remedy: The spiral shaft is removed or the motor is not rotating. Check these items.
------------------------------
Code: 12020303
Display:
Used by: GSP5
Cause: The cylinder takes too long (10 seconds or longer) to return.
Remedy: The air pressure is too low, the piston section has a load on it, or the upper limit confirmation
sensor (in the upper part of the cylinder section) has slipped. Check each of these items and make
adjustments.
------------------------------
Code: 12020305
Display:
Used by: GSP5
Cause: The solder outflow setting is out of range.
Remedy: Specify 8.0 cm3/s or less.
------------------------------
Code: 12020306