FUJI错误代码查询.pdf - 第2160页
Cause: When using automatic nozzle arrangement, the required number of nozzles exceed the number in the nozzle folder. Remedy: The program file is incorrect. Check the Nozzle Spec. file, or check the Minimum Nozzle Diame…
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct.
When the stage number value is 1, the slot number input range is 1 to 100.
------------------------------
Code: 2305003D
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The stage number value is 2, but the slot number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct.
When the stage number value is 2, the slot number input range is 1 to 400.
------------------------------
Code: 2305003E
Display: The stage/slot numbers for the following feeder setup in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
The device number input range is 1 to 500.
When specifying a stage - slot arrangement, when stage 1 is specified, the slot number input range is 1 to
100, and when stage 2 is specified, the slot number input range is 1 to 400.
------------------------------
Code: 2305003F
Display: The stage number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
The stage number input range is 1 to 2.
------------------------------
Code: 23050040
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The stage number value is 1, but the slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
When the stage number value is 1, the slot number input range is 1 to 100.
------------------------------
Code: 23050041
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The stage number value is 2, but the slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
When the stage number value is 2, the slot number input range is 1 to 400.
------------------------------
Code: 23050042
Display: Even if nozzle kinds are combined so that the maximum diameter nozzles are not used, there are
too many nozzle kinds to fit in the folder.
Used by:
第 2159 页
Cause: When using automatic nozzle arrangement, the required number of nozzles exceed the number in
the nozzle folder.
Remedy: The program file is incorrect. Check the Nozzle Spec. file, or check the Minimum Nozzle
Diameter (PARTS/ENVDT/XP241ENVDT-/PENMI) and Maximum Nozzle Diameter
(PARTS/ENVDT/XP241ENVDT-/PENMA) settings in the part data.
------------------------------
Code: 23050043
Display: An inputted nozzle name does not exist in Nozzle Configuration File and the Nozzle Specification
File.
Used by:
Cause: The inputted nozzle name does not exist in the Nozzle Configuration file and Nozzle Specification
file.
Remedy: Try optimizing the program using [Automatic Nozzle Arrangement]. If still unsuccessful, check
the Nozzle Spec. file, or check the Minimum Nozzle Diameter (PARTS/ENVDT/XP241ENVDT-/PENMI) and
Maximum Nozzle Diameter (PARTS/ENVDT/XP241ENVDT-/PENMA) settings in the part data.
------------------------------
Code: 23050044
Display: There is no nozzle suitable for the part.
Used by:
Cause: There is no suitable nozzle available in the nozzle folder for the part.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle arrangement] method. If using [Automatic Nozzle
Arrangement], check the Nozzle Spec. file, or check the Minimum Nozzle Diameter
(PARTS/ENVDT/XP241ENVDT-/PENMI) and Maximum Nozzle Diameter (PARTS/ENVDT/XP241ENVDT-
/PENMA) settings in the part data.
------------------------------
Code: 23050045
Display: There is no nozzle of the name specified for the parts.
Used by:
Cause: In the nozzle folder, there is no nozzle of the name specified for the parts.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle arrangement] method. If using [Automatic Nozzle
Arrangement], check the Nozzle Spec. file, or check the Nozzle Name (PARTS/ENVDT/XP241ENVDT-
/PENNZN) in the part data.
------------------------------
Code: 23050047
Display: The Alt. Feeder number must be set to a different slot. Set the Alt. Feeder number to 0?
Used by:
Cause: A Alt. Feeder number has been set for the same slot.
Remedy: In the program file's Feeder Setup settings, and change the Alt. Feeder number
(PROGRAM/DEVICE+/GUTNSLTN) to 0 (No Alt. Feeder) or to another slot number.
------------------------------
Code: 23050048
Display: A Alt. Feeder is duplicated, or two or more first slots (reference slot) have been specified for the
same alternate feeder loop.
The Alt. Feeder settings will be deleted.
Used by:
Cause: Two or more alternate feeder loops may be overlapping.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
第 2160 页
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2305004A
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a loop did not exist. The Alt. Feeder setting is zero.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2305004B
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a non-existent Alt. Feeder setting was found.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2305004C
Display: Nozzle name is not specified. Assume as a standard nozzle?
Used by:
Cause: In the Nozzle folder information file, the Nozzle name is not specified for "GNANAM".
Remedy: When [Yes] is selected, standard Nozzle name is specified according to the diameter. When [No]
is selected, no Nozzle is specified to the Nozzle folder.
------------------------------
Code: 230500A1
Display: The source program is already in an optimized condition. It is not possible to further optimize the
source program.
Used by:
Cause: The post-optimized theoretical cycle time is slower than the pre-optimized time, however, source
program sequence or feeder setup problems have been fixed.
Remedy: It may be possible to achieve a better cycle time result by changing the optimization conditions,
if production constraints allow.
------------------------------
Code: 23060003
Display: The tape width is outside the specifications or is zero.
Used by:
Cause: The packaging name (PARTS/HEADER/CMPNAME) or the tape width (PARTS/PACKLS-
/TAPEWIDTH) is outside the specifications or is zero. For packaging name, one of the following types must
be specified: E08xx, E12xx, E16xx, E24xx, E32xx, J32xx, E44xx, E56xx, E72xx, E88xx. For tape width,
one of the following must be specified: 8, 12, 16, 24, 32, 44, 56, 72, 88.
Remedy: The tape width setting in the part data is incorrect. Check the file contents.
------------------------------
Code: 23060005
Display: A feeder does not exist in the slot referred to in the sequence.
Used by:
Cause: A feeder does not exist in the slot referred to in the sequence.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23060006
Display: Part data referred to by the sequence slot does not exist.
第 2161 页