FUJI错误代码查询.pdf - 第1918页
Remedy: Check the input filename. ------------------------------ Code: 21006817 Display: Input file error Used by: Cause: The input file is incorrect. Remedy: Check the input file. ------------------------------ Code: 21…
Display: Off_line read error
Used by:
Cause: Unable to read the off-line descriptor.
Remedy: Check the off-line descriptor.
------------------------------
Code: 21006805
Display: Off_line error
Used by:
Cause: The off-line descriptor is incorrect.
Remedy: Check the off-line descriptor.
------------------------------
Code: 21006810
Display: Data checker error
Used by:
Cause: An error occurred at the data checker.
Remedy: Check the program.
------------------------------
Code: 21006811
Display: Part data error
Used by:
Cause: The Part data file is incorrect.
Remedy: Check Part data.
------------------------------
Code: 21006812
Display: Part data error
Used by:
Cause: The Part data file is incorrect.
Remedy: Check Part data.
------------------------------
Code: 21006813
Display: Input file error
Used by:
Cause: The input file is incorrect.
Remedy: Check the input file.
------------------------------
Code: 21006814
Display: Input file read error
Used by:
Cause: Unable to read the input file.
Remedy: Check the input file.
------------------------------
Code: 21006815
Display: Input file error
Used by:
Cause: The input file is incorrect.
Remedy: Check the input file.
------------------------------
Code: 21006816
Display: Input file name over error
Used by:
Cause: The input filename is too long.
第 1917 页
Remedy: Check the input filename.
------------------------------
Code: 21006817
Display: Input file error
Used by:
Cause: The input file is incorrect.
Remedy: Check the input file.
------------------------------
Code: 21006818
Display: Output file error
Used by:
Cause: The output file is incorrect.
Remedy: Check the output file.
------------------------------
Code: 21006819
Display: GLgen_Parameter file error
Used by:
Cause: GLgen parameter is incorrect.
Remedy: Check the GLgen parameter file.
------------------------------
Code: 2100681A
Display: Traial_dot space error
Used by:
Cause: The trial dot area is incorrect.
Remedy: Check the trial dot area.
------------------------------
Code: 2100681B
Display: Nothing G_mark_data in Mark_data division
Used by:
Cause: There is no glue check in the mark data section.
Remedy: Check the program mark data section.
------------------------------
Code: 21006820
Display: ls command error
Used by:
Cause: The ls command produced an error.
Remedy: Re-execute the function. If it still doesn't work, re-install the software.
------------------------------
Code: 21006821
Display: GL_generator command error
Used by:
Cause: The GL_generator command produced an error.
Remedy: Re-execute the function. If it still doesn't work, re-install the software.
------------------------------
Code: 21006822
Display: Input file over <max 8>
Used by:
Cause: There are too many input files.
Remedy: Check the input files.
------------------------------
Code: 21006823
第 1918 页
Display: GLgen_Parameter file error
Used by:
Cause: GLgen parameter is incorrect.
Remedy: Check the GLgen parameter file.
------------------------------
Code: 21006824
Display: Memory error
Used by:
Cause: The memory cannot be saved.
Remedy: Re-boot MCS.
------------------------------
Code: 21006825
Display: Memory error
Used by:
Cause: The memory cannot be saved.
Remedy: Re-boot MCS.
------------------------------
Code: 21006826
Display: Input file over
Used by:
Cause: The input file is too long.
Remedy: Check the input file.
------------------------------
Code: 21006827
Display: Total sequence over <max 5000>
Used by:
Cause: There are too many sequences.
Remedy: Check the number of sequences in the program.
------------------------------
Code: 21006828
Display: Total Device over <max 500>
Used by:
Cause: There are too many devices.
Remedy: Check the number of devices in the program.
------------------------------
Code: 21006829
Display: Traial_dot space error
Used by:
Cause: The trial dot area is incorrect.
Remedy: Check the trial dot area.
------------------------------
Code: 2100682A
Display: Part Data reference by Device_data dose not exist.
Used by:
Cause: The Part data referenced by the device data cannot be found.
Remedy: Check the Part data being used by the program.
------------------------------
Code: 2100682B
Display: Part Data reference by Device_data dose not contain GL_gen d
Used by:
Cause: The GL_gen data referenced by the device data cannot be found.
第 1919 页