FUJI错误代码查询.pdf - 第754页
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2) "Command Abort (Emg Stop)" (QP2) PM?? ERROR Code:******** (QP132) Used by: QP242,QP201,QP202,QP203,QP132 Cause: The command was canceled by an emerg…
"Problem With Parts Supply" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: has stopped because of a problem with the supply of components from a device.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Remove the cause of the component supply problem, press the RESET switch, and restart the
machine.
------------------------------
Code: 12070?D5
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Sequence Index Number" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: A sequence index number is incorrect.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure that the quantity of placing sequences in each module does not exceed 1,000.
------------------------------
Code: 12070?D6
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Recovery Count Not Reached" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The PMC stopped without performing the maximum number of recoveries
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
(as reported in MCHSTP).
Remedy: This is not a problem. Press the RESET switch, then restart the machine.
------------------------------
Code: 12070?D7
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Next Device Not Specified" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The PMC stopped recovering because a next device has not been specified.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the "Vision_type" and "Element_Data" parameters in the Part data for the device in
question.
------------------------------
Code: 12070?D8
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"All Next Device Used" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The PMC stopped recovering because all of the next device specifications have been used.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the "Vision_type" and "Element_Data" parameters in the Part data for the device in
question.
------------------------------
Code: 12070?D9
第 753 页
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Command Abort (Emg Stop)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command was canceled by an emergency stop.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: This is not a problem. Remove the error factor that caused the emergency stop, press the
RESET switch, and restart the machine.
------------------------------
Code: 12070?DA
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Mark Read Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Mark read error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the mark coordinate data and the mark data in the program data.
------------------------------
Code: 12070?DB
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Cannot dump parts" (QP2)
Used by: QP202,QP203
Cause: The machine attempted to dump parts even though there is no reject parts location.
Remedy: Turn the vacuum to OFF.
------------------------------
Code: 12070?DC
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Skip was recorded for all block skip marks read" (QP2)
Used by: QP202,QP203,QP242
Cause: As a result of the block skip mark positions read, all the blocks at the indicated module will be
skipped. ? is the module number. "****" is the error code.
Remedy: Remove the board from the machine. Do not add 32 to Proper data item "Machine status A" to
prevent an error occurring under these circumstances.
------------------------------
Code: 12070?E0
Display: PM?? ERROR Code:********
"Required feeders not set"(QP132)
Used by: QP132
Cause: Cannot find relevant PFU information.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Set a necessary feeder.
------------------------------
Code: 12070?F0
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"F-ROM Voltage Too Low" (QP2)
"Command Abort (Emg Stop)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by:
Cause: The F-ROM voltage is low.
(value replacing "?" is module number; error code appears in place of asterisks)
第 754 页
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?F1
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"F-ROM Command Seq Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: F-ROM command sequence error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?F2
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"F-ROM Block Delete Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: F-ROM block deletion error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?F3
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"F-ROM Write Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: F-ROM write error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?F4
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Start comnd w/o SV firmware" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A start command was received while no SV firmware was present.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
第 755 页