Used by: Cause: The carrier dropped a part. Remedy: Feed another part to the carrier. ------------------------------ Code: 11074430 Display: Used by: IP2 Cause: Parts were not moved to the machine. Remedy: Check the carr…
------------------------------
Code: 1107430D
Display:
Used by: IP2
Cause: Proper data's recovery setting is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 1107430E
Display:
Used by: IP2
Cause: Proper data's carrier X position is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 1107430F
Display:
Used by: IP2
Cause: Proper data's carrier Y position is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074310
Display:
Used by: IP2
Cause: Proper data's part pickup time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074311
Display:
Used by: IP2
Cause: Proper data's part carrier movement timer is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074312
Display:
Used by: IP2
Cause: Proper data's remover pickup timer is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074400
Display:
Used by: IP2
Cause: The SY axis and the tray is not in the safety position.
Remedy: Return the SY axis and tray to the safety position.
------------------------------
Code: 11074410
Display:
Used by: IP2
Cause: The part was not moved from the sub-nozzle to the carrier.
Remedy: Check the sub-nozzle and the carrier.
------------------------------
Code: 11074420
Display:
第 196 页
Used by:
Cause: The carrier dropped a part.
Remedy: Feed another part to the carrier.
------------------------------
Code: 11074430
Display:
Used by: IP2
Cause: Parts were not moved to the machine.
Remedy: Check the carrier.
------------------------------
Code: 11074440
Display: MTU Positioning Err
Used by: IP2
Cause: The tray movement command was not carried out correctly.
Remedy: Turn off the power at the IP2 and the MTU, and re-boot.
------------------------------
Code: 11074450
Display: MTU Error
Used by:
Cause: An error occurred at the MTU.
Remedy: Turn off the power at the IP2 and the MTU, and re-boot.
------------------------------
Code: 11075001
Display: L3 SCAN_S COM
Used by: IP1,IP2,IP3
Cause: Transmission (to the L3 board) of a command to start scanning resulted in an error, or a timeout
condition.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again.
------------------------------
Code: 11075002
Display: L3 SCAN_S PRC
Used by: IP1,IP2,IP3
Cause: A command to start scanning was sent to the L3 board, and an error was returned, or a timeout
condition occurred.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again.
------------------------------
Code: 11075003
Display: L3 SCAN_E COM
Used by: IP1,IP2,IP3
Cause: Transmission (to the L3 board) of a command to start scanning resulted in an error, or a timeout
condition. This may be due to one of the following causes: the L3 board baud rate is set below 9600
(timeout), not all the leads could be measured, or the encoder cable/sensor cable is not properly
connected.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. Check that the length of
the leads in 10.Lead_length_x and Lead_length_y in Vision_data are the same as the actual leads. Check
that the size entered in Body_size is the same as the actual body size. Make Coplanarity item 4.Y_offset
bigger so that the measurement is done farther from the tips of the leads. Check that the encoder cable is
properly connected to the CyberOptics board. Check that the sensor cable is properly connected to both
the sensor and the CyberOptics board. The cable should be connected to jumper 1. If the error recurs,
第 197 页
turn off the power and start again.
------------------------------
Code: 11075004
Display: L3 COP_CAL COM
Used by: IP1,IP2,IP3
Cause: A command to the L3 board to start coplanarity calculations resulted in an internal processing
error, or a timeout condition occurred. Remedy: If the L3 board baud rate is set below 9600, set it to
9600 or greater. If the error recurs, turn off the power and start again.
Remedy:
------------------------------
Code: 11075005
Display: L3 COP_CAL PRC
Used by: IP1,IP2,IP3
Cause: A command to start coplanarity calculations was sent to the L3 board, and an internal processing
error was returned, or a timeout condition occurred.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again. Check that the part has 2, 3 or 4 leaded sides. If the part has only one leaded
side, coplanarity calculations cannot be carried out.
------------------------------
Code: 11075006
Display: L3 ENC_RES SET
Used by: IP1,IP2,IP3
Cause: An error occurred when the machine tried to set the encoder resolution value for L3.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again.
------------------------------
Code: 11075007
Display: L3 ENG DATA
Used by: IP1,IP2,IP3
Cause: An error or timeout condition occurred when the machine attempted to call up engineering data
from the L3 board.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again.
------------------------------
Code: 11075008
Display: L3 Para SET
Used by: IP1,IP2,IP3
Cause: An error or timeout condition occurred when the machine attempted to set L3 parameters
(linearity tolerance or coplanarity tolerance).
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again.
------------------------------
Code: 11075009
Display: L3 SCAN_E PRC
Used by: IP1,IP2,IP3
Cause: Transmission (to the L3 board) of a command to stop scanning resulted in an error, or a timeout
condition. This may be due to one of the following causes: the L3 board baud rate is set below 9600
(timeout), not all the leads could be measured, or the encoder cable/sensor cable is not properly
connected.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. Check that the width and
length of the leads in 10.Lead_length_x and Lead_length_y in Vision_data are the same as the actual leads.
第 198 页