FUJI错误代码查询.pdf - 第665页
production program issues an error if a non-STU type feeder is set within 9 slots since it would intefere with the STU.(NP2) Feeders cannot be set inside the interference area due to the possibility of interference with …
------------------------------
Code: 12066C05
Display: RADDS error
Used by: NP2,QP3
Cause: RADDS not connected.
Remedy: RADDS failed to start. Reset the part power supply.
------------------------------
Code: 12066C06
Display: RADDS error
Used by: NP2,QP3
Cause: RADDS failed to start.
Remedy: Reset the part power supply.
------------------------------
Code: 12066C07
Display: RADDS error
Used by: NP2,QP3
Cause: Wafer supply to RADDS was not completed within the prescribed period. Wafer door remains
open.
Remedy: Supply RADDS with wafers, then close the wafer door.
------------------------------
Code: 12066C08
Display: RADDS error
Used by: NP2,QP3
Cause: Unidentified part at RADDS.
Remedy: Inspect the RADDS front shuttle.
------------------------------
Code: 12066C09
Display: RADDS error
Used by: NP2,QP3
Cause: An error occurred during RADDS resetting.
Remedy: Cut the power to the RADDS and then reboot.
------------------------------
Code: 12066C0A
Display: Eject conveyor error
Used by: NP2,QP3
Cause: Feeder is present in slot specified for the reject parts conveyor.
Remedy: Check to see if a feeder is present in the slot indicated in the parameter slot display. Check to
see if a feeder is specified in the production program.
------------------------------
Code: 12066C0B
Display: Nozzle setting error
Used by: NP2,QP3
Cause: Nozzle catch sensor is ON even a although no nozzle is installed.
Remedy: Ensure if a nozzle is set in the holder.If so, reject the nozzle.
------------------------------
Code: 12066C0C
Display: STU data error
Used by: NP2,QP3
Cause: A non-STU type feeder exists within 9 slots to either side of the STU.(NP2)
A feeder has been set in the STU interference area.(QP3)
Remedy: It is prohibited to set non-STU type feeders within 9 slots at both sides of the STU. The
第 664 页
production program issues an error if a non-STU type feeder is set within 9 slots since it would intefere
with the STU.(NP2)
Feeders cannot be set inside the interference area due to the possibility of interference with the placing
head. Set all feeders outside the STU interference area.(QP3)
------------------------------
Code: 12066C0D
Display: STU error
Used by: NP2,QP3
Cause: The STU to be used with the PFU is not set to a slot specified in the production program.
Remedy: Set an STU in the slot specified in the production program.
------------------------------
Code: 12066C0E
Display: STU error
Used by: NP2,QP3
Cause: The STU to be used with the PFU is not set to a slot specified in
the production program.
Remedy: Set an STU in the slot specified in the production program.
------------------------------
Code: 12066C10
Display: Air removal failed
Used by: QP3
Cause: Stable glue dots cannot be produced due to insufficient air removal.
Remedy: Remove the air again.
------------------------------
Code: 12066C11
Display: Glue check tolerance error(QP3)
Used by: QP3
Cause: Production cannot be commenced because the glue application amount check result exceeded the
area tolerance.
Remedy: Clean the needle and screw.
------------------------------
Code: 12066C13
Display: Ion condition error
Used by: QP3
Cause: Ion emissions from the ionizer (static suppressor) are either being absorbed, or the machine
environment is unstable. Such conditions can affect the charge-neutralizing capability.
Remedy: Push [EMERGENCY STOP], verify that there is no conductive material near the ionizer, then
push [READY ON] to clear the error.
------------------------------
Code: 12066C14
Display: Pick-up position check -- interference error
Used by: QP3
Cause: The pick-up position check indicates possible interference between the head and the device.
Perform production with the pick-up position check disabled.
Remedy: Cancel the pick-up position check operation.
------------------------------
Code: 12066C15
Display: Pick-up position check -- interference area error
Used by: QP3
Cause: Device interference may occur within the interference range of the device where the pick-up
position check occurs. Perform production with the pick-up position check disabled.
第 665 页
Remedy: Do not place an interfering device within the interference range of the device where the pick-up
position check occurs.
------------------------------
Code: 12066C16
Display: Barcode Test Error
Used by: QP3
Cause: The barcode cannot be read because the loading confirmation sensor detects a panel.
Remedy: Move the detected panel out of the machine so the loading confirmation sensor is no longer
activated.
------------------------------
Code: 12066C17
Display: Insertion error
Used by: QP3
Cause: The Z-axis did not reach the placing height. Check for the placing condition.
Remedy: If placement was not completed, see "Remedy1". Otherwise, see "Remedy2". Remedy1:
Following are possible reasons the Z-axis did not reach the placing height:- The pins are bent. - A foreign
object exists in the placing area. - The pin holes on the panel are defective (the size or location does not
match or holes are blocked with solder paste.) - The X- and Y-coordinates specified in the program are
incorrect. - The Clamp Height, and Part Height specified in the program are incorrect. - The pin locations
specified in element information in the program are incorrect. - The height offset is incorrect. - The placing
thrust pressure is too small. - The program origin is incorrect. Remedy2: Check the following:- The
Placing Thrust Pressure is too small. - The Placing Motion Selection is incorrect. (Change to Placing Thrust
Pressure 2)
------------------------------
Code: 12066C18
Display: Insertion error
Used by: QP3
Cause: The Z-axis is too much lower than the placing thrust pressure completion height.
Remedy: Following are possible reasons for this condition:- The backup pins are not in an appropriate
position or the panel is warped. - The placing thrust pressure is too high.
------------------------------
Code: 12066C19
Display: Insertion error
Used by: QP3
Cause: The Z-axis arrived at the placement height, however the placement thrust pressure torque was
not reached. Check the placement condition.
Remedy: If placement was not completed, see "Remedy1". Otherwise, see "Remedy2". Remedy1:
Following are possible reasons for this condition:\n- The backup pins are not in an appropriate position or
the panel is warped. - The value in the "Offset Z" field of part data is not appropriate. - The value in the
"Placement Thrust Pressure" field of part data is not appropriate. - The placement height in calibration
data is not correct. Remedy 2: Check the following if placement was completed correctly and an error
occurred:- The backup pins are not in an appropriate position or the panel is warped. - The value in the
"Placement Thrust Pressure" field of part data is not appropriate. - The Placing Motion Selection is
incorrect. (Change to Placing Thrust Pressure 3)
------------------------------
Code: 12066C1A
Display: Insertion error
Used by: QP3
Cause: The placement thrust pressure torque was reached before the Z-axis reached the placement
height. Check the placement condition.
Remedy: If placement was not completed, see "Remedy1". Otherwise, see "Remedy2". Remedy1:
第 666 页