FUJI错误代码查询.pdf - 第555页

Used by: QP132 Cause: X066: The SS_PLT_UNCLAMP did not come off in the given time. Remedy: Check the operation using I/O commands and adjust if necessary. ------------------------------ Code: 12054069 Display: SS UNCLAMP…

100%1 / 5282
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054061
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054062
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054063
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054064
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054065
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054066
Display: SS_PIN ON TUP
Loader error: 12054066
Used by: QP132
Cause: X06A: The SS_PIN_ON did not come on in the given time.
Remedy: Check the operation using I/O commands and adjust if necessary.
------------------------------
Code: 12054067
Display: SS_PIN OFF TUP
Loader error: 12054067
Used by: QP132
Cause: X06B: The SS_PIN_OFF did not come on in the given time.
Remedy: Check the operation using I/O commands and adjust if necessary.
------------------------------
Code: 12054068
Display: SS CLAMP TUP
Loader error: 12054068
第 554 页
Used by: QP132
Cause: X066: The SS_PLT_UNCLAMP did not come off in the given time.
Remedy: Check the operation using I/O commands and adjust if necessary.
------------------------------
Code: 12054069
Display: SS UNCLAMP TUP
Loader error: 12054069
Used by: QP132
Cause: X066: The SS_PLT_UNCLAMP did not come on in the given time.
Remedy: Check the operation using I/O commands and adjust if necessary.
------------------------------
Code: 1205406A
Display: 周期异常 主挡块
Used by: GP551,GP6,GPX,NXTP,GPX-C
Cause: 在规定时间内无法进行主挡块的进入和退出。
Remedy: 请确认传感器MAIN搬运轨道挡块导入确认(X06D: MN STPR ON CHK)。 另外,请确认主挡块的上下
是否有干涉物、是否有负荷。 1.干涉:存在障碍物(电路板等)时,请除去障碍物。
2.是否动作:请使用I/O检查停止块是否动作。可考虑为电气断线,气源配管故障等。
3.传感器是否有输入:存在断线的可能性。请使用I/O进行停止块输入确认,停止块解除确认的传感器输入检查。
(请与本公司的Support联系)
4.请进行电路板停止块上升下降端的传感器位置的调整。(GPX)
<img src="$LKEY_ERRIMG_MC$/1205406A.PNG">
------------------------------
Code: 1205406B
Display: "Cycle alarm: solder cutter" (GP-6)
Used by:
Cause: The solder cutter required longer than the specified time to move up or down.
Remedy: Use I/O commands to check the solder cutter upper limit sensor
(1106:PASTE CUT UP) and the solder cutter lower limit sensor (1107:PASTE CUT DN).
------------------------------
Code: 1205406C
Display: "Cycle alarm: solder pusher" (GP6, GP5), "Insufficient solder in squeegee (GP6, GP5)
Used by: GP551,GP6
Cause: The solder pusher required longer than the specified time to move up or down, or an insufficiency
of solder was detected by the pusher's lower limit sensor.
Remedy: Use I/O commands to check the pusher upper limit sensor (X072:PUSHER UP) and the pusher
lower limit sensor (1107:PUSHER DN). Supply solder if needed.
------------------------------
Code: 1205406D
Display: Flux station error
Used by:
Cause: An error has occurred during the preliminary operation prior to application by the flux supply
unit. An error was detected during the preliminary operation by the sequencer which controls theflux
supply unit.
Remedy: Make sure that each of the flux supply unit actuators are working correctly. Confirm that each
of the flux supply unit sensors switch on and off correctly.
------------------------------
Code: 1205406E
Display: Flux station cycle alarm
Used by:
Cause: Although the preliminary operation for flux supply unit dispensing was conducted, the operation
第 555 页
did not register as being completed even after the specified amount of time had elapsed. After the feed
signal for a feeder came on, the feed completion signal of the device feeder in question did not come on
even though the specified amount of time had elapsed.
Remedy: Make sure that each of the flux supply unit actuators are working correctly. Confirm that each
of the flux supply unit sensors switch on and off correctly. Make sure the flux supply unit isproperly
installed on the MFU.
------------------------------
Code: 1205406F
Display: Error occurred on flux station or stick feeder
Used by:
Cause: An error occurred either during the preliminary operation for flux supply unit dispensing or while
parts were being supplied by a stick feeder.
Remedy: Make sure that each of the flux supply unit and stick feeder actuators are working
correctly.Confirm that each of the flux supply unit and stick feeder sensors switch on and off correctly.
------------------------------
Code: 12054070
Display: "Air Cylinder Cycle Alarm SCR Lifter"
Used by: GP6
Cause: The screen lifter did not operate within the specified time.
Remedy: Adjust the screen lifter so that it operates normally. Make sure that the upper limit and lower
limit sensors are functioning normally.
------------------------------
Code: 12054071
Display: "Air Cylinder Cycle Alarm SCR Chuck"
Used by: GP6
Cause: The screen transport chuck did not operate within the specified time.
Remedy: Adjust the screen transport chuck so that it operates normally. Make sure that the close limit
and open limit sensors are functioning normally.
------------------------------
Code: 12054072
Display: "Air Cylinder Cycle Alarm SCR Push"
Used by: GP6
Cause: The screen pusher cylinder did not operate within the specified time.
Remedy: Adjust the ejection cylinder so that it operates normally. Make sure that the forward end and
retract end sensors are functioning normally.
------------------------------
Code: 12054073
Display: "Pal Transport Err UPELV->IN"
Used by: CP652C
Cause: Either the forward end check sensor for the cylinder of the pallet conveyor between the UP
elevator and the IN position has not turned on even though the specified time has elapsed since the
cylinder was instructed to start moving, or the pallet movement complete status was not achieved when
the forward end check sensor turned on. "Pallet movement complete status" is as follows: when the pallet
IN cylinder forward end check sensor turns on, the pallet IN cylinder retract end check sensor should b
off, the IN position pallet check sensor should be on, the UP elevator pallet check sensor should be off,
and the UP elevator pallet passage check sensor should be on.
Remedy: Make sure that nothing is obstructing pallet movement. If there is no obstruction, perform an
I/O check on the input from the following sensors: pallet IN cylinder forward end check (X088) and retract
end check (X089), IN position pallet check (X046), UP elevator pallet check (X084), and UP elevator pallet
passage check (X085). Adjust the sensors as necessary.
------------------------------
第 556 页