FUJI错误代码查询.pdf - 第1083页

Display: 1404000F Used by: Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is excessive. There may be a foreign object on the nozzle. Remedy: Check the camera, the vision proc…

100%1 / 5282
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040008
Display: 14040008
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040009
Display: 14040009
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 1404000A
Display: 1404000A
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 1404000B
Display: 1404000B
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 1404000C
Display: 1404000C
Used by:
Cause: The length in the y direction is too small.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 1404000D
Display: 1404000D
Used by:
Cause: The length in the y direction is too small.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 1404000F
第 1082 页
Display: 1404000F
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040010
Display: 14040010
Used by:
Cause: The length in the x direction is too small.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 14040011
Display: 14040011
Used by:
Cause: The length in the x direction is too big.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 14048002
Display: 14048002
Used by:
Cause: The nozzle cannot be found. There is nothing in the image.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 140482??
Display: 140482??
Used by:
Cause: The nozzle length is too long in the x direction.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct.
------------------------------
Code: 140483??
Display: 140483??
Used by:
Cause: The nozzle length is too short in the x direction.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct.
------------------------------
Code: 140484??
Display: 140484??
Used by:
Cause: The nozzle length is too long in the y direction.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct.
------------------------------
Code: 140485??
Display: 140485??
第 1083 页
Used by:
Cause: The nozzle length is too short in the y direction.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct.
------------------------------
Code: 1404C4??
Display: 1404C4??
Used by:
Cause: The left edge of the nozzle cannot be found.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct. Check the image acquisition conditions.
------------------------------
Code: 1404C5??
Display: 1404C5??
Used by:
Cause: The lower edge of the nozzle cannot be found.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct. Check the image acquisition conditions.
------------------------------
Code: 1404C6??
Display: 1404C6??
Used by:
Cause: The right edge of the nozzle cannot be found.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct. Check the image acquisition conditions.
------------------------------
Code: 1404C7??
Display: 1404C7??
Used by:
Cause: The upper edge of the nozzle cannot be found.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct. Check the image acquisition conditions.
------------------------------
Code: 1404D000
Display: 拿回机械夹头元件出错。
如果带有元件时,请用手将其取下。
Used by: XP241,XP341,XP242
Cause: 拿回机械夹头元件出错。
Remedy: 如果带有元件时,请用手将其取下。
基准定位点有污垢时,请拆下机械夹头清除污垢。
------------------------------
Code: 1404D001
Display: 编辑失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 影像处理数据错误
Remedy: 是内部错误,一般不发生。如果发生的话,请获取跟踪数据,并将它送至弊社。
------------------------------
Code: 1404D003
Display: 在周期自动补正中吸嘴的影像处理失败。
Used by: XP241,XP341,XP242
Cause: 在周期自动补正中吸嘴的影像处理失败。
第 1084 页