FUJI错误代码查询.pdf - 第1084页
Used by: Cause: The nozzle length is too short in the y direction. Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the acquired image is correct. ---…
Display: 1404000F
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040010
Display: 14040010
Used by:
Cause: The length in the x direction is too small.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 14040011
Display: 14040011
Used by:
Cause: The length in the x direction is too big.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 14048002
Display: 14048002
Used by:
Cause: The nozzle cannot be found. There is nothing in the image.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 140482??
Display: 140482??
Used by:
Cause: The nozzle length is too long in the x direction.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct.
------------------------------
Code: 140483??
Display: 140483??
Used by:
Cause: The nozzle length is too short in the x direction.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct.
------------------------------
Code: 140484??
Display: 140484??
Used by:
Cause: The nozzle length is too long in the y direction.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct.
------------------------------
Code: 140485??
Display: 140485??
第 1083 页
Used by:
Cause: The nozzle length is too short in the y direction.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct.
------------------------------
Code: 1404C4??
Display: 1404C4??
Used by:
Cause: The left edge of the nozzle cannot be found.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct. Check the image acquisition conditions.
------------------------------
Code: 1404C5??
Display: 1404C5??
Used by:
Cause: The lower edge of the nozzle cannot be found.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct. Check the image acquisition conditions.
------------------------------
Code: 1404C6??
Display: 1404C6??
Used by:
Cause: The right edge of the nozzle cannot be found.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct. Check the image acquisition conditions.
------------------------------
Code: 1404C7??
Display: 1404C7??
Used by:
Cause: The upper edge of the nozzle cannot be found.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct. Check the image acquisition conditions.
------------------------------
Code: 1404D000
Display: 拿回机械夹头元件出错。
如果带有元件时,请用手将其取下。
Used by: XP241,XP341,XP242
Cause: 拿回机械夹头元件出错。
Remedy: 如果带有元件时,请用手将其取下。
基准定位点有污垢时,请拆下机械夹头清除污垢。
------------------------------
Code: 1404D001
Display: 编辑失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 影像处理数据错误
Remedy: 是内部错误,一般不发生。如果发生的话,请获取跟踪数据,并将它送至弊社。
------------------------------
Code: 1404D003
Display: 在周期自动补正中吸嘴的影像处理失败。
Used by: XP241,XP341,XP242
Cause: 在周期自动补正中吸嘴的影像处理失败。
第 1084 页
Remedy: 请确认吸嘴直径是否正确。
请确认吸嘴的表面是否有伤痕和污垢。
请确认闪光灯是否发光。
------------------------------
Code: 1404D004
Display: 在周期自动补正中测定吸嘴置放地失败。
Used by: XP241, XP341
Cause: 在周期自动补正中测定吸嘴置放地失败。
Remedy: 请确认吸嘴直径是否正确。
请确认吸嘴的表面是否有伤痕和污垢。
请确认闪光灯是否发光。
------------------------------
Code: 1404D005
Display: 检查出吸嘴表面的异物。请确认完成电路板中是否遗漏贴装。
Used by: XP141,XP142
Cause: 检查出吸嘴表面的异物(包括吸嘴表面的伤痕)。
Remedy: 请确认吸嘴表面是否异常。
------------------------------
Code: 1404D006
Display: 不能检验出吸嘴中心。
Used by: XP241,XP341,XP242
Cause: 不能检验出吸嘴中心。
Remedy: 请确认吸嘴直径是否正确。
请确认吸嘴的表面是否有伤痕和污垢。
请确认闪光灯是否发光。
------------------------------
Code: 1404D007
Display: 吸嘴尺寸检查错误
由影像处理进行的吸嘴尺寸检查发生了错误。
请确认吸嘴编辑的设定数据和已设置的吸嘴是否一致。
请确认吸嘴的表面是否有伤痕或污垢。
请确认闪光灯是否发光。
Used by: XP241,XP341,XP242
Cause: 用影像处理进行的吸嘴尺寸检查发生了错误。
Remedy: 请确认吸嘴编辑的设定数据和已设置的吸嘴是否一致。
请确认吸嘴的表面是否有伤痕和污垢。
请确认闪光灯是否发光。
------------------------------
Code: 1404D008
Display: 检测出吸嘴表面有污垢,有可能不能正确地进行影像处理。
Used by: XP142,XP242
Cause: 检测出吸嘴表面有污垢,有可能不能正确地进行影像处理。
Remedy: 请确认以下状态,并排除故障。
·请确认发生错误的吸嘴上是否附有异物、污垢或伤痕。
有异物、污垢时请清扫。另外、吸嘴上有伤痕时,请使用别的吸嘴。
·请确认发生错误的SIDE的棱镜上是否附有异物。
有污垢时请清扫。
·请确认影像处理区域内是否安装了吸嘴。
区域内没有吸嘴时,请安装吸嘴。(XP142)
·相机影像太亮或太暗时,设定的亮度不正确。
请按照调整的步骤调整亮度。
第 1085 页