FUJI错误代码查询.pdf - 第167页
Display: Used by: IP3 Cause: The carrier position Z1 position has not been specified even though carrier 1 is supposed to pick parts from MFU1. Remedy: Input the pulse count of the Z1 axis at the picking position of carr…
Remedy: Measure the pulse values from the center of the mark camera to the center of the 1st pin check
camera(#1). Input this value into 111.IC_Mark_Camera_Pos.X for the FLT and
112.IC_Mark1_Camera_Pos.X for the FIP3.
------------------------------
Code: 11022907
Display:
Used by:
Cause: The 1st pin check camera (#2) position has not been specified.
Remedy: Measure the pulse values from the center of the mark camera to the center of the 1st pin check
camera(#2). Input this value into 114.IC_Mark2_Camera_Pos.X for the FIP3.
------------------------------
Code: 11022908
Display:
Used by: IP3
Cause: No reflow position value has been input.
Remedy: Measure the pulse value obtained from measuring the distance from the placing nozzle (after
zero setting) to the center of rotation of the reflow head. Input this into Proper data item
113.Reflow_Position_X for the FLT.
------------------------------
Code: 11022909
Display:
Used by: IP3
Cause: The distance from placing nozzle 1 to the board surface has not been specified.
Remedy: Specify the pulse count of the distance from the position of nozzle 1 (after zero setting) to the
surface of the board. Input this into Proper data item 123.Origin_Position_Z for the FLT and
130.Origin_Position_Z1 for the FIP3.
------------------------------
Code: 1102290A
Display:
Used by: IP3
Cause: The distance from placing nozzle 2 to the board surface has not been specified.
Remedy: Specify the pulse count of the distance from the position of nozzle 1 (after zero setting) to the
surface of the board. Input this into Proper data item 131.Origin_Position_Z1 for the FIP3.
------------------------------
Code: 1102290B
Display:
Used by:
Cause: The carrier position Z1 position has not been specified even though carrier 1 is supposed to pick
parts from MTU1.
Remedy: Input the pulse count of the Z1 axis at the picking position of carrier 1. For the FLT, use
124.Carrier_Position_Z. For the FIP3, use 132.Carrier_Position_Z1.
------------------------------
Code: 1102290C
Display:
Used by:
Cause: The carrier position Z2 position has not been specified even though carrier 2 is supposed to pick
parts from MTU2.
Remedy: Input the pulse count of the Z2 axis at the picking position of carrier 2. For the FIP3, use
132.Carrier_Position_Z1.
------------------------------
Code: 1102290D
第 166 页
Display:
Used by: IP3
Cause: The carrier position Z1 position has not been specified even though carrier 1 is supposed to pick
parts from MFU1.
Remedy: Input the pulse count of the Z1 axis at the picking position of carrier 1. For the FLT, use
125.MFU1_Position_Z. For the FIP3, use 134.MFU1_Position_Z1.
------------------------------
Code: 1102290E
Display:
Used by: IP3
Cause: The carrier position Z2 position has not been specified even though carrier 2 is supposed to pick
parts from MFU2.
Remedy: Input the pulse count of the Z2 axis at the picking position of carrier 2. For the FLT, use
126.MFU2_Position_Z. For the FIP3, use 132.MFU2_Position_Z1.
------------------------------
Code: 1102290F
Display:
Used by: IP3
Cause: The nozzle change position has not been input for nozzle 1 even though that nozzle is to be
changed.
Remedy: Input the Z1 axis nozzle change position into Proper data
127.Nozzle_change_Pos.Z for the FLT and
136.Nozzle_change_Pos.Z1 for the FIP3.
------------------------------
Code: 11022910
Display:
Used by: IP3
Cause: The nozzle change position has not been input for nozzle 2 even though that nozzle is to be
changed.
Remedy: Input the Z1 axis nozzle change position into Proper data
137.Nozzle_change_Pos.Z2 for the FIP3.
------------------------------
Code: 11022911
Display:
Used by: IP3
Cause: The zero set position in the Q1 axis has not been input for nozzle 1.
Remedy: Input the Q1 axis zero set position into Proper data
128.Origin_Position_Q for the FLT and
138.Origin_Position_Q1 for the FIP3.
------------------------------
Code: 11022912
Display:
Used by: IP3
Cause: The zero set position in the Q2 axis has not been input.
Remedy: Input the Q2 axis zero set position into Proper data item
139.Origin_Position_Q2 for the FIP3.
------------------------------
Code: 11022913
Display:
Used by: IP3
Cause: The X2 axis plus movement range has not been specified.
第 167 页
Remedy: Specify the X2 axis plus movement range in Proper data item
136.Max_Limit_Position_X2 for the FLT and
146.Max_Limit_Position_X2 for the FIP3.
------------------------------
Code: 11022914
Display:
Used by: IP3
Cause: The Y axis plus movement range has not been specified.
Remedy: Specify the Y axis plus movement range in Proper data item
137.Max_Limit_Position_Y for the FLT and
147.Max_Limit_Position_Y for the FIP3.
------------------------------
Code: 11022915
Display:
Used by: IP3
Cause: The X1 axis plus movement range has not been specified.
Remedy: Specify the X1 axis plus movement range in Proper data item
143.Max_Limit_Position_X1 for the FLT and
152.Max_Limit_Position_X1 for the FIP3.
------------------------------
Code: 11022916
Display:
Used by: IP3
Cause: RCU line port setting is out of range.
Remedy: Input a value into Proper data's 158.RCU_line_Port setting.
------------------------------
Code: 11022917
Display:
Used by: IP3
Cause: The RCU line port was previously set to a different setting.
Remedy: Input a correct value into Proper data's 158.RCU_line_Port setting.
------------------------------
Code: 11022A00
Display: 11022A00
Used by: QP132
Cause: The RB servo communication port number is not specified.
Remedy: Specify the correct data for 110. Servo Control Port No. in Proper data. When connecting to the
second VM 1440 board, channel 1 is 17, 2 is 18, etc (17 is input when shipped)
------------------------------
Code: 11022A01
Display: 11022A01
Used by: QP132
Cause: The offset value between boards was not input for operation with multiple boards in one pallet.
Remedy: Specify the correct data for 125. PCB Setup tolerance in Proper data.
------------------------------
Code: 11022A02
Display: 11022A02
Used by: QP132
Cause: The program origin x coordinate for mark reading was not input.
Remedy: Specify the correct data for 141. Mark Read Position MXC in Proper data.
------------------------------
第 168 页