FUJI错误代码查询.pdf - 第1141页

Code: 1504043C Display: panel conveyance error. Used by: CP-732E, CP-742ME, CP-742E Cause: The Out 1 panel arrival sensor or the Out 2 panel arrival sensor was off when the out-lifter was being moved up and down for the …

100%1 / 5282
(4)Because the in-carrier is at neither the advance limit nor the retract limit position, a panel absent
status cannot be confirmed on the in-carrier.
Loading to the out-lifter is not possible. Although an out-lifter loading command (out-carrier panel is
unloaded to the out-lifter) was executed, the out-loader is disabled due to one of the following 4
conditions:
(1)There is a panel on the out-conveyor (out-conveyor panel sensor has detected a panel ).
(2)The out-carrier is at its advance limit position, and the panel cannot be clamped (out-carrier panel
sensor detects no panel ).
(3)The out-carrier is at its retract limit position, and a panel present status cannot be confirmed on the
out-carrier.
(4)Because the out-carrier is at neither the advance limit nor the retract limit position, a panel present
status cannot be confirmed on the out-carrier.
An improper panel unloading command was executed at the loader while in the IDLE mode.
An improper unloading command was attempted at the loader.
An improper loader command was attempted during operation (AUTO, COMMAND, IDLE mode) with the
out-loader ready to receive a panel from the main lifter.
Improper operation signal switched on during AUTO mode operation.
Improper operation signal switched on during COMMAND mode operation.
Improper operation signal switched on during IDLE mode operation.
An improper command was attempted while measuring the in-loader panel conveyance time.
An improper command was attempted while measuring the out-loader panel conveyance time. An
improper operation signal switched on while measuring the out-loader panel conveyance time.
There is no operation corresponding to the issued command.
Remedy: When improper command errors occur, use the machine's trace function to obtain trace data.
------------------------------
Code: 15040439
Display: Out-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A panel conveyance error occurred at the out-carrier. The Out 1 panel arrival sensor switched off
at some point between the start of out-lifter UP motion and the completion of panel unloading to the out-
lifter.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating properly.
------------------------------
Code: 1504043A
Display: Out-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A panel conveyance error occurred at the out-carrier. The Out 2 panel arrival sensor switched off
at some point between the start of out-lifter UP motion and the completion of panel unloading to the out-
lifter.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating properly.
------------------------------
Code: 1504043B
Display: Out-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: When unloading a panel to the out-lifter, the out-carrier panel sensor switched on when the out-
carrier moved to its advance limit position.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating properly.
------------------------------
第 1140 页
Code: 1504043C
Display: panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The Out 1 panel arrival sensor or the Out 2 panel arrival sensor was off when the out-lifter was
being moved up and down for the out-conveyor panel check.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating properly.
------------------------------
Code: 1504043D
Display: Out-carrier clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamp sensor operation is unstable at the out-carrier's advance limit side.
Remedy: Check the clamp sensor operation, and verify that the conveyor width is suitable for the panel in
question.
------------------------------
Code: 1504043E
Display: Panel unloading error
Used by: CP-752E
Cause: A panel was unloaded from the main-conveyor, however, the out-conveyor panel arrival sensor
(X0C7) did not detect the p
anel within the specified time limit.
Remedy: Check that the out-conveyor panel arrival sensor is functioning properly and confirm the panel
status.
------------------------------
Code: 1504043F
Display: Panel unloading error
Used by: CP-752E
Cause: An attempt was made to unload the panel to the next machine, however, the out-conveyor panel
arrival sensor (X0C7) did
not deactivate (OFF) within the specified time limit.
Remedy: Check that the out-conveyor panel arrival sensor is functioning properly and confirm the panel
status.
------------------------------
Code: 15040440
Display: Panel unloading error
Used by: CP-752E
Cause: This error occurs if panel exchange (send next panel) is set to take place when the out-conveyor
unload panel sensor (X
0CB) is deactivated.
Remedy: Check that the out-conveyor panel arrival sensor is working properly and confirm the panel
status.
------------------------------
Code: 15040441
Display: 向OUT搬运轨道的电路板到达传感器的电路板搬运失败。
Used by: XP143,XP243
Cause: 向OUT搬运轨道的电路板到达传感器的电路板搬运失败。
Remedy: 请确认电路板在搬运途中是否被钩住。
请确认OUT搬运轨道到达传感器(X00E:OutStArriveChk)是否正常地动作。
------------------------------
Code: 15040442
Display: OUT搬运轨道升降台的上升失败。
第 1141 页
Used by: XP143,XP243
Cause: OUT搬运轨道升降台的上升失败。
Remedy: OUT搬运轨道升降台未上升时,请确认通过OUT升降台的配管是否脱离
上升时,请确认以下传感器是否正常地动作。
<XP143>
·OUT搬运轨道升降台的上升确认传感器(X026:OutStLftUpChk)
<XP243>
·OUT搬运轨道升降台的上升确认传感器1(X040:OutStLftUpChk1)
·OUT搬运轨道升降台的上升确认传感器2(X041:OutStLftUpChk2)
------------------------------
Code: 15040443
Display: OUT搬运轨道的升降台下降失败。
Used by: XP143,XP243
Cause: OUT搬运轨道的升降台下降失败。
Remedy: OUT搬运轨道的升降台未下降时,请确认通过OUT搬运轨道的升降台的配管是否脱离。
下降时,请确认以下的传感器是否正常地动作。
<XP143>
·OUT搬运轨道升降台的上升确认传感器(X026:OutStLftUpChk)
<XP243>
·OUT搬运轨道升降台的上升确认传感器1(X040:OutStLftUpChk1)
·OUT搬运轨道升降台的上升确认传感器2(X041:OutStLftUpChk2)
------------------------------
Code: 15040444
Display: 电路板位置异常 送出侧
Used by: GPX
Cause: 在送出侧搬运轨道无法搬运的位置上存在电路板。
Remedy: 请除去电路板。
<img src="$LKEY_ERRIMG_MC$/EI0009.bmp">
------------------------------
Code: 15040445
Display: 载出搬运轨道有电路板错误
Used by: NXTP
Cause: 因为在载出搬运轨道上有电路板,所以不进入到下一步的处理。
Remedy: 请清除电路板。
<img src="$LKEY_ERRIMG_MC$/15040445.PNG">
------------------------------
Code: 15040446
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 15040447
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 15040448
Display:
Used by:
第 1142 页