Used by: Cause: "Tray" is specified as the packaging type, but the "Tray Row Quantity" item is set to "0". Remedy: When using the "Tray" packaging type, specify a "Tray Row Qu…
Check the Element settings.
Change the Vision Type.
------------------------------
Code: 2300E5B0
Display: [Packaging Type]-[Feed Count] is not defined.
Used by:
Cause: A [Packaging Type]-[Feed Count] setting of "0" existed when the [Packaging Type]-[Type] setting
was other than [0:Tray], [4:Stick Feeder], [5:Grooved Stick Feeder].
Remedy: Specify a [Packaging Type]-[Feed Count] setting when the [Packaging Type]-[Type] setting is other
than [0:Tray], [4:Stick Feeder], [5:Grooved Stick Feeder].
------------------------------
Code: 2300E5B1
Display: Tape Width is not defined.
Used by:
Cause: A Packaging Data "Tape Width" setting of "0" existed when the [Packaging Type]-[Type] setting
was other than [0:Tray].
Remedy: Specify a "Tape Width" setting.
------------------------------
Code: 2300E5B2
Display: Set a value less than 4 if the Packaging Type is specified as Stick Feeder or Grooved Stick feeder.
Used by:
Cause: The stick feeder "FeedCount" is set to 4 or more.
Remedy: When using the Stick Feeder and Grooved Stick Feeder packaging types, specify a "FeedCount"
setting of 3 or less.
------------------------------
Code: 2300E5B3
Display: Make a setting at Packaging Type.
Used by:
Cause: Packaging Type is not specified in the part packaging data.
Remedy: Specify the packaging type in the Packaging edit window.
------------------------------
Code: 2300E5D0
Display: Tray Length is not defined.
Used by:
Cause: "Tray" is specified as the packaging type, but there is no "Tray Length" setting.
Remedy: When using the "Tray" packaging type, specify a "Tray Length" setting.
------------------------------
Code: 2300E5D1
Display: Tray Width is not defined.
Used by:
Cause: "Tray" is specified as the packaging type, but there is no "Tray Width" setting.
Remedy: When using the "Tray" packaging type, specify a "Tray Width" setting.
------------------------------
Code: 2300E5D2
Display: Tray Column Quantity is not defined.
Used by:
Cause: "Tray" is specified as the packaging type, but the "Tray Column Quantity" item is set to "0".
Remedy: When using the "Tray" packaging type, specify a "Tray Column Quantity" setting of 1 or higher.
------------------------------
Code: 2300E5D3
Display: Tray Row Quantity is not defined.
第 2138 页
Used by:
Cause: "Tray" is specified as the packaging type, but the "Tray Row Quantity" item is set to "0".
Remedy: When using the "Tray" packaging type, specify a "Tray Row Quantity" setting of 1 or higher.
------------------------------
Code: 2300E5D4
Display: Tray Length is not correct. Can't eject tray.
Used by:
Cause: The length of the tray to be unloaded (Tray Type 0 or 2) is set as smaller than the remover.
Remedy: Specify a "Tray Length" setting of 72 or higher.
------------------------------
Code: 2300E5D5
Display: Tray Width is not correct. Can't eject tray.
Used by:
Cause: The width of the tray to be unloaded (Tray Type 0 or 2) is set as smaller than the remover.
Remedy: Specify a "Tray Width" setting of 83 or higher.
------------------------------
Code: 2300E5D6
Display: Tray Dump Pick Position X is not correct. Can't eject tray.
Used by:
Cause: The remover (nozzle used to unload trays) protrudes beyond the tray in the X-direction when
picking up a tray.
Remedy: Specify the "Tray Dump Pick Position X" setting so that the remover does not protrude beyond
the tray in the X-direction when picking up trays. (Setting value should satisfy the following equation.)
72 / 2 =< [Tray Dump Pick Position X] x (-1) =< [Tray Width] - (72 / 2)
------------------------------
Code: 2300E5D7
Display: Tray Dump Pick Position Y is not correct. Can't eject tray.
Used by:
Cause: The remover (nozzle used to unload trays) protrudes beyond the tray in the Y-direction when
picking up trays.
Remedy: Specify the "Tray Dump Pick Position Y" setting so that the remover does not protrude beyond
the tray in the Y-direction when picking up trays. (Setting value should satisfy the following equation.)
83 / 2 =< [Tray Dump Pick Position Y] =< [Tray Width] - (83 / 2)
------------------------------
Code: 2300E5D8
Display: The pick up point for the last tray parts exceeds the tray size in the X-direction.
Used by:
Cause: The final pickup position for tray parts exceeds the tray's X-direction size.
Remedy: Specify a setting value which satisfies the following equation.
[Tray Length] => { [Tray First Pickup Position X] x (-1) } + { [Tray Column Pitch] x ( [Tray Column Quantity]
- 1) }
------------------------------
Code: 2300E5D9
Display: The pick up point for the last tray parts exceeds the tray size in the Y-direction.
Used by:
Cause: The final pickup position for tray parts exceeds the tray's Y-direction size.
Remedy: Specify a setting value which satisfies the following equation.
[Tray Width] => [Tray First Pickup Position Y] + [Tray Row Pitch] x ( [Tray Row Quantity] - 1 )
------------------------------
Code: 2300E5DA
Display: Tray cannot be removed. Input the tray thickness (4.00mm - 25.40mm).
第 2139 页
Used by:
Cause: The tray dimensions are outside the permissible XP tray specifications (4.00mm - 25.40mm).
Remedy: Remedy: Input a permissible tray thickness (4.00mm - 25.40mm).
------------------------------
Code: 2300E5DB
Display: Set [Tray Length] to 95.00 mm or more when using the power remover.
Used by:
Cause: The power remover cannot be used to eject trays if the "Tray Length" setting is less than 95.00
mm.
(Only the standard remover can be used)
Remedy: When using the power remover, set "Tray Length" to 95.00 mm or more.
------------------------------
Code: 2300E5DC
Display: Set [Tray Width] to 95.00 mm or more when using the power remover.
Used by:
Cause: The power remover cannot be used to eject trays if the "Tray Width" setting is less than 95.00
mm.
(Only the standard remover can be used)
Remedy: When using the power remover, set "Tray Width" to 95.00 mm or more.
------------------------------
Code: 2300E5DD
Display: The current [Tray Dump Pick Position X] setting is incorrect when using the power remover.
Used by:
Cause: The power remover cannot be used to eject trays with the specified "Tray Dump Pick Position X"
setting.
(Only the standard remover can be used)
Remedy: When using the power remover, set "Tray Dump Pick Position X" so that the remover picks up
the tray at the correct position.
(Use the following formula to set the correct value.)
95 / 2 =< [Tray Dump Pick Position X] x (-1) =< [Tray Length] - (95 / 2)
------------------------------
Code: 2300E5DE
Display: The current [Tray Dump Pick Position Y] setting is incorrect when using the power remover.
Used by:
Cause: The power remover cannot be used to eject trays with the specified "Tray Dump Pick Position Y"
setting.
(Only the standard remover can be used)
Remedy: When using the power remover, set "Tray Dump Pick Position Y" so that the remover picks up
the tray at the correct position.
(Use the following formula to set the correct value.)
95 / 2 =< [Tray Dump Pick Position Y] =< [Tray Width] - (95 / 2)
------------------------------
Code: 23040005
Display: A feeder does not exist in the slot referred to in the sequence.
Used by:
Cause: A feeder does not exist in the slot referred to in the sequence.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23040006
Display: Part data referred to by the sequence slot does not exist.
Used by: