making contact with the board or the PPC. ------------------------------ Code: 12056008 Display: Certify to B_mark Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643 Cause: The B-marks that the machine read are …

100%1 / 5282
with a specific nozzle, inspect the nozzle detection locations for the specified head.
------------------------------
Code: 12056003
Display: 侧夹紧传感器逻辑异常
Used by: GSP5,GP551,GP6,GPX,GPX-C
Cause: 侧松开传感器或侧夹紧正常传感器的输入在逻辑上变得不正常。(GSP5) 即使电路板松开,侧夹紧落空确认传
感器也没有ON。 (GPX)
Remedy: 请进行侧松开传感器或侧夹紧正常传感器的调整/更换,使之变成以下的逻辑。
电路板松开时 正常夹紧时 夹紧失败时
松开 ○ × ×
正常夹紧 ○ ○ ×(GSP5) 1.请确认是否有妨碍了侧夹紧动作的落下电路板等的
存在。
2.什么也没有时,需要进行电路板侧夹紧落空确认传感器(GPX:RX006,GPX-C:IN10)的调整。(请与本公司的
Support联系)(GPX,GPX-C)
<img src="$LKEY_ERRIMG_MC$/EI0007.bmp">
------------------------------
Code: 12056004
Display: Sldr unit Position Error
Used by: GSP5
Cause: The position of the automatic paste dispenser is unacceptable.
Remedy: The adjustment of the sensor is probably incorrect. Adjust the sensor so that it corresponds
with the position of the automatic paste dispenser.
------------------------------
Code: 12056005
Display: Wrong Sqg Pres Data
Used by: GSP5
Cause: This error occurs only when the print pressure feedback option is in use.When measuring the
print pressure, a Low signal which was higher than the Hi signal was detected. This indicates that there
is an error in the Hi/Low logic specified in the print comparator. Furthermore, the low signal (X072 SQG
PRES LO) may be short circuited to GB.
Remedy: The print pressure input logic must be specified in the following manner: Hi is greater than
Low.Check that the high/low wiring is correct (GSP5). The pressure change/time gradient is too
steep.Adjust the Pressure/Time control item in Proper data to give a less steep gradient.
------------------------------
Code: 12056006
Display: M/C err Sqg Pres Range Over
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: This error occurs only when print pressure feedback is being used. Although the control pressure
dropped below 0% or exceeded 100% when print pressure feedback was being used, the print pressure did
not automatically return to the specified range.
Remedy: The print pressure input logic must be specified in the following manner: Hi is greater than
Low.The printing height may be too low or there may be something between the screen and the board
(GSP5).
------------------------------
Code: 12056007
Display: Error : PPC origin positon sensor
Used by: IP3
Cause: During calibration the reference position check sensor did not come on when parts were being
placed, or the sensor was already on when operation began.
Remedy: At the I/O map check that the reference position check sensor turns on and off
correctly.Furthermore, check the sensor and the nozzle if the sensor is on even when the nozzle is not
第 574 页
making contact with the board or the PPC.
------------------------------
Code: 12056008
Display: Certify to B_mark
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The B-marks that the machine read are all considered as "skip".
Remedy: Ensure that the B-marks are in the specified position of the program. After restarting the
machine, the B-marks arereread. Press the unload button to unload the board.
------------------------------
Code: 12056009
Display: "Pal Transport Err On R.Conv"
Used by: CP652C
Cause: The rear conveyor pallet arrival sensor has failed to indicate the arrival of a pallet within the
specified time.
Remedy: Make sure that the pallet is not stuck on the rear conveyor, and that nothing is obstructing
pallet movement.If there is no obstruction, perform an I/O check on the pallet arrival check sensor
(X09E), and adjust the sensor as necessary.
------------------------------
Code: 1205600A
Display: "Cleaner sensor logical alarm"
Used by: GP6
Cause: There is a logic error in input from the cleaner position check sensors.
Remedy: The logic error is in the following sensors: X05C:CLNR ZERO POS, X03E:CLNR NEAR CHK, and
X07C:CLNR SHIFT RET.In the case of a double-side cleaner, these three sensors should never all turn on
at once. The error may be caused by a wiring error or a sensor malfunction. Check the sensors and adjust
as necessary.
------------------------------
Code: 1205600B
Display: "Sensor logical alarm: upper cleaner head" (GP6)
Used by: GP6
Cause: The upper cleaner head open limit (X07C) and close limit (X07D) sensors have either both turned
on or both turned off at the same time.
Remedy: Check the upper cleaner head open limit and close limit sensors, and adjust them as necessary.
------------------------------
Code: 1205600C
Display: "Sensor logical alarm: lower cleaner head" (GP6)
Used by: GP6
Cause: The lower cleaner head open limit (X05A) and close limit (X05B) sensors have either both turned
on or both turned off at the same time.
Remedy: Check the lower cleaner head open limit and close limit sensors, and adjust them as necessary.
------------------------------
Code: 1205600D
Display: "Sensor logical alarm: cleaner notch" (GP6)
Used by: GP6
Cause: The cleaner notch sensors (X05D and X05E) sensors have either both turned on or both turned
off at the same time.
Remedy: If the machine supports a double-side cleaner, check and adjust the sensors for the notch that
connects the cleaner to the S-axis. If the machine uses a single-side cleaner, check and adjustthe sensors
for the notch that connects the cleaner to the cleaner shift.
------------------------------
Code: 1205600E
第 575 页
Display: "Sensor logical alarm: cleaner shift" (GP6)
Used by: GP6
Cause: The cleaner shift forward end (X07C) and retract end (X07D) sensors have either both turned on
or both turned off at the same time.
Remedy: Check the cleaner shift forward end and retract end sensors, and adjust them as necessary.
------------------------------
Code: 1205600F
Display: "M/C err Sensor SQG Holder" (GP6 w/single squeegee), "M/C err Sensor
SQG F" (front squeegee on double-squeegee GP6), "M/C err Sensor SQG R"
(rear squeegee on double-squeegee GP6)
Used by: GP6
Cause: The squeegee holder upper limit and lower limit check sensors (X070 and X071 for either a single
squeegee or squeegee F, and X078 and X079 for squeegee R) have either both turned on or both turned off
at the same time.
Remedy: Check the squeegee holder upper limit and lower limit check sensors, and adjust them as
necessary.
------------------------------
Code: 12056010
Display: "M/C err Sensor Top Cleaner Connected"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056011
Display: "Sensor Logic Error Conveyor Width Clutch"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056012
Display: "Sensor Logic Error Push Plate"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056013
Display: "M/C err Sensor Holder **(UPorDOWN)"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056014
Display: "Sensor Logic Error SQG Open/Close"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.