Cause: The input program data type is inappropriate. Remedy: Use the Editor to check the input program's machine type. ------------------------------ Code: 21007626 Display: Input program file expand error Used by: …
Display: Que datqa moving error
Used by:
Cause: Unable to process the memory.
Remedy: Re-boot MCS. If the error recurs, re-install the software.
------------------------------
Code: 2100761E
Display: Que data sortting error
Used by:
Cause: Unable to process the memory.
Remedy: Re-boot MCS. If the error recurs, re-install the software.
------------------------------
Code: 2100761F
Display: Que data get error
Used by:
Cause: Unable to retrieve the memory.
Remedy: Re-boot MCS. If the error recurs, re-install the software.
------------------------------
Code: 21007620
Display: Strategy file read error
Used by:
Cause: Unable to read the system (strategy) file.
Remedy: Re-boot MCS. If the error recurs, re-install the software.
------------------------------
Code: 21007621
Display: Make not mark sequence
Used by:
Cause: Special sequences were not created.
Remedy: This message displays when there is a program without special sequences. It is all right to
continue running the program.
------------------------------
Code: 21007622
Display: No entry Input program file name
Used by:
Cause: The input program filename has not been input.
Remedy: Input the filename.
------------------------------
Code: 21007623
Display: Out put program file already exists
Used by:
Cause: An output file with the same name already exists.
Remedy: Either change the name of the output file, or overwrite the old file.
------------------------------
Code: 21007624
Display: Input program file data type unmatch.
Used by:
Cause: The input program data type is inappropriate.
Remedy: Use the Editor to check that the input program is the production program.
------------------------------
Code: 21007625
Display: Input program file machine type unmatch
Used by:
第 1949 页
Cause: The input program data type is inappropriate.
Remedy: Use the Editor to check the input program's machine type.
------------------------------
Code: 21007626
Display: Input program file expand error
Used by:
Cause: During expansion of the input program, an error occurred.
Remedy: Use [Cntrl] + [E] to check the contents of the expander.
------------------------------
Code: 21007627
Display: Part data file name get error
Used by:
Cause: A compatible Part data name has not been entered in the device number used by the sequence.
Remedy: Input a compatible Part data name into the program device data.
------------------------------
Code: 21007628
Display: Same davice comment entry in PST file
Used by:
Cause: A device comment with the same name exists in the PST file.
Remedy: The same name cannot be used. Change the comment.
------------------------------
Code: 21007629
Display: No entry Cartridge name in PST file
Used by:
Cause: The feeder name has not been entered in the PST file.
Remedy: Input the feeder name.
------------------------------
Code: 2100762A
Display: Can not feedback Fix device
Used by:
Cause: Unable to feed back the fixed device. The fixed device's device number is incorrect.
Remedy: Check the PST file device number.
------------------------------
Code: 2100762B
Display: Cartridge type unmatch
Used by:
Cause: The feeder type is incorrect.
Remedy: The feeder type described in Part data cannot be used. Input a different feeder type.
------------------------------
Code: 2100762C
Display: No used Cartridge
Used by:
Cause: An unused feeder exists. There is a feeder which does not use any sequences.
Remedy: This is a warning. It is all right to continue running the program if this situation is acceptable
to the user.
------------------------------
Code: 2100762D
Display: Can not setting Fix device data
Used by:
Cause: There is not enough space between the feeders.
Remedy: Change the PST file device number.
第 1950 页
------------------------------
Code: 2100762E
Display: Can not setting Next device data
Used by:
Cause: As there are too many devices in use, the next device cannot be set.
Remedy: Reduce the number of devices in use.
------------------------------
Code: 2100762F
Display: Next device not found
Used by:
Cause: The next device was not found.
Remedy: This message appears when there is no next device specified in the program.
------------------------------
Code: 21007630
Display: Cartridge name get error
Used by:
Cause: The feeder name is not input in the Device_name section of Sep_data in Part data.
Remedy: Check that the Part data has been entered correctly.
------------------------------
Code: 21007631
Display: Station over
Used by:
Cause: The device cannot be placed in the station.
Remedy: Join the feeders. Alternately, stop using the PST or the base program. Alternately, use fewer
devices.
------------------------------
Code: 21007632
Display: Occupancy data read error
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 21007633
Display: Slot info data read error
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 21007634
Display: New program file has no sequence
Used by:
Cause: There are no sequences in the new program file.
Remedy: Use the editor to check the input file.
------------------------------
Code: 21007635
Display: Parts height regulation over
Used by:
Cause: The part height exceeds the set limit.
Remedy: Check the Part data part height. It must be 4 mm or less on the FCP-II, and 6 mm or less on
other machines.
------------------------------