Cause: An inappropriate process within the system was stopped. ( Additional ) Remedy: 1.Switch the machine power off and on. 2.If the error occurs again, acquire trace data from the machine under the conditions in which …
------------------------------
Code: 93FB0000
Display: 吸嘴更换器就座异常
Used by: NXT,AIM
Cause: 机器中记忆的就座状态与I/O传感器的状态不一致。
(补充编码)
Remedy: 对不起麻烦您获取发生错误时机器的跟踪数据,与敝公司Support联系。
------------------------------
Code: 93FC0000
Display: 没有测定吸嘴的安装位置
Used by: NXT,AIM
Cause: 由于没有测定吸嘴的安装位置,所以不能进行吸嘴的切换。
(补充编码)
Remedy: 对不起麻烦您获取发生错误时机器的跟踪数据,与敝公司Support联系。
------------------------------
Code: 93FD0000
Display: 元件废弃
Used by: NXT,AIM
Cause: 元件废弃时发生异常
(补充编码)
Remedy: 详细请参照子错误编码。
------------------------------
Code: 93FE0000
Display: 不是可以进行吸嘴切换的配置
Used by: NXT,AIM
Cause: 安装了F04料盘用的吸嘴置放台时,吸嘴头A或者吸嘴头D无法从奇数的吸嘴槽中进行吸嘴切换。
( 补充编码 没有 )
Remedy: 请按照向导,重新配置吸嘴。还是无法解决时,请确认Job的NozzleStationSetup中的吸嘴配置。
------------------------------
Code: 93FF0000
Display: 快门开闭超时
Used by: NXT,AIM
Cause: NXT-H:虽然发出了吸嘴更换器的快门开闭指示,但不能测出在规定时间内完成动作。(补充编码),NXT-
H,NEO,MWU12i,SNC,NXTP,REELLOADER
Remedy: NXT-H:如果Z轴保持在下降状态,最初请进行下记1~4的作业。1.请解除吸嘴和置放台的干涉状态。2.在
相应吸嘴头上有吸嘴时,请取下吸嘴。3.确认吸嘴是否在正常动作、是否有伤痕等,如果有问题请交换。4.请将取下的
吸嘴重新装到取下的吸嘴置放台上后重新开始运转。Z轴上升时,确认吸嘴没有异常,必要时请更换。此外,请确认吸
嘴更换器的快门开闭的状态。必要时请清扫·加油。
------------------------------
Code: 94000000
Display: 内部处理异常( 元件影像处理测试 )
Used by: NXT,AIM
Cause: 系统内发生了处理异常。
( 补充编码 )
Remedy: 对不起麻烦您获取错误发生时的跟踪数据,连同错误发生时的操作步骤一起与弊公司Support联系。为了重
新开始运转,请重新接通总电源开关。
------------------------------
Code: 94010000
Display: Machine application error
Used by: NXT,AIM
第 4789 页
Cause: An inappropriate process within the system was stopped.
( Additional )
Remedy: 1.Switch the machine power off and on.
2.If the error occurs again, acquire trace data from the machine under the conditions in which the error
occurs, and contact your Fuji representative.
------------------------------
Code: 94020000
Display: An error occurred during a vision processing test.
Used by: NXT,AIM
Cause: An error occurred at a unit.
( Additional )
Remedy: Refer to the unit error code (Additional code).
If necessary, clear the vision processing test mode and clear the error.
After clearing the error, perform the vision processing test again.
------------------------------
Code: 94030000
Display: A time out occurred while acquiring the result of a vision processing test.
Used by: NXT,AIM
Cause: A time out occurred while acquiring the result of a vision processing test.
( Additional )
Remedy: 1.Remove the part being held by the nozzle by hand.
2.Turn the machine power off and on.
------------------------------
Code: 94040000
Display: The status of a feeder is not Set OK.
Used by: NXT,AIM
Cause: Pickup cannot be performed because the status of a feeder is not Set OK.
( Additional )
Remedy: 1.Reset the feeder on the machine.
2.Check that the LED above the feeder turns green.
3.Perform the vision processing test again.
------------------------------
Code: 94050000
Display: 料盘的状态没有处在SetOK状态。
Used by: NXT,AIM
Cause: 由于料盘的状态没有处在SetOK状态,因此不能吸取。
( 补充编码 )
Remedy: 请执行以下的1~4的步骤。
1.请结束吸取测试指令,执行自动运转。
2.请根据料盘安装向导安装料盘,变成电路板等待状态。
3.请按下机器的周期停止按钮,变成START等待。
4.请再次执行吸取测试指令。
------------------------------
Code: 94060000
Display: The vision processing test cannot be continued because the job
was deleted.
Used by: NXT,AIM
Cause: A job was transmitted from MEdit during the vision processing
test but the job was disabled or deleted because it could not be
transmitted or it failed the data check.
( Additional )
第 4790 页
Remedy: Switch off the vision processing test mode and transmit the job
again.
------------------------------
Code: 94070000
Display: 因工作头电源OFF而无法取得工作头的信息
Used by: NXT,AIM
Cause: 在确认是否为能够影像处理的工作头时,因工作头电源OFF而无法取得工作头的信息。
(补充编码 无)
Remedy: 请按下开始按钮,使工作头的电源ON。
之后,通过周期停止按钮停止运转,然后再次执行影像处理测试指令。
------------------------------
Code: 94080000
Display: MWU8i 吸取-影像处理测试异常发生
Used by: NXT,AIM
Cause: MWU8i 吸取-影像处理测试中发生了异常。
( 补充编码 )
Remedy: 请参照子错误编码。
《子错误编码》
3:在机器上不存在Job。
4:机器为传送模式的设定。请在开始处理时解除传送模式。
5:机器的Profiler设定为有效。请在开始处理时解除Profiler设定。
6:机器为PAM模式。请在开始处理时解除PAM模式。
7:机器为故障运用。请在开始处理时解除故障运用。
8:机器为空转模式。
d:因为工作头没有被连接,不能开始处理。
e:因为吸嘴置放台没有被连接,不能开始处理。
10:是不能执行指令的工作头种类。
13:因为正在吸取自动运转中的元件,不能开始测试。
------------------------------
Code: 94090000
Display: 虽然执行了MWU 吸取测试、影像处理测试,但是需要进行换线或MWU上的各定位点读取。
Used by: NXT,AIM
Cause: 虽然执行了MWU 吸取测试、影像处理测试,但是需要进行换线或MWU上的各定位点读取。
( 补充编码 )
Remedy: 1.请退出MWU 吸取测试、影像处理测试模式,执行自动运转。
2.请根据换线向导进行换线。
定位点读取没有被进行时,机器自动进行读取。
请最终为电路板等待状态。
3.请按下机器的周期停止按钮,成为START等待。
4.请重新执行MWU 吸取测试、影像处理测试。
------------------------------
Code: 940A0000
Display: 数据编辑范围外异常
Used by: NXT,AIM
Cause: MWU中编辑的数据超出了公差范围,因此不能反映给机器。
( 补充编码 )
Remedy: 请修正Pickup-Offset的值,再次按下开始按钮。
详细内容请参照单元错误编码。
------------------------------
Code: 940B0000
Display: Vision Processing Test命令无法执行