FUJI错误代码查询.pdf - 第775页

Used by: QP132 Cause: PMC board communication error. SVdata transmission error(Handshake timeout2). (value replacing "?" is module number; error code appears in place of asterisks) (value replacing "??&quo…

100%1 / 5282
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis command pulse error (outside software limit range).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: The Y-axis movement target position exceeds the limit values specified in the Proper data.
Check the movement target value and the Proper data values.
------------------------------
Code: 12074?22
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Command Out of Soft Lim (Z)" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Z-axis command pulse error (outside software limit range).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: The Z-axis movement target position exceeds the limit values specified in the Proper data.
Check the movement target value and the Proper data values.
------------------------------
Code: 12074?23
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Command Out of Soft Lim (Q)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Q-axis command pulse error (outside software limit range).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: The Q-axis movement target position exceeds the limit values specified in the Proper data.
Check the movement target value and the Proper data values.
------------------------------
Code: 12074?31
Display: PM?? ERROR Code:********
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(Handshake error).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12074?32
Display: PM?? ERROR Code:********
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(Handshake timeout1).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12074?33
Display: PM?? ERROR Code:********
第 774 页
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(Handshake timeout2).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12074?40
Display: PM?? ERROR Code:********
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(No data).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12074?41
Display: PM?? ERROR Code:********
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(Handshake timeout1).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12074?42
Display: PM?? ERROR Code:********
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(Handshake timeout2).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12074?43
Display: PM?? ERROR Code:********
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(Block count error).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12076?02
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"X-axis(-) Overtravel" (QP2)
第 775 页
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The X-axis has overtraveled in the (-) direction.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Use inching to cancel the overtravel.
------------------------------
Code: 12076?03
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"X-axis(+) Overtravel" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The X-axis has overtraveled in the (+) direction.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Use inching to cancel the overtravel.
------------------------------
Code: 12076?04
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"X-axis Servo Amp Error" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: X-axis servo driver error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether something is interfering with the axis, whether the axis action has become
extremely heavy, or whether an error has occurred in the servo amp.
------------------------------
Code: 12076?05
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"X-axis PG Disconnection Err" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: X-axis PG disconnection error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether the connector has become disconnected from the servo axis, or whether an error
has occurred in the servo amp.
------------------------------
Code: 12076?0B
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"X-axis Positioning Time Out" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: X-axis positioning timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether something is interfering with the axis, whether the axis action has become
extremely heavy, or whether an error has occurred in the servo amp.
------------------------------
Code: 12076?0C