FUJI错误代码查询.pdf - 第1368页
Code: 1D0CF??? Display: Used by: Cause: There was a logical error in the management program. Remedy: Check Part data. ------------------------------ Code: 1D0D0002 Display: Used by: Cause: The part cannot be picked. Reme…
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0CC4??
Display:
Used by:
Cause: An edge could not be detected on the left side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0CC5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0CC6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0CC7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0CD000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D0CD080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D0CE???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
第 1367 页
Code: 1D0CF???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D0D0002
Display:
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D0D0010
Display:
Used by:
Cause: The part is tilted at an angle exceeding 45 deg..
Remedy: Check that the nozzle is clean, and that the part is clean. Check that the correct part is being
picked.
------------------------------
Code: 1D0D0011
Display:
Used by:
Cause: The X length is too short.
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
Code: 1D0D0012
Display:
Used by:
Cause: The X length is too long.
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
Code: 1D0D0013
Display:
Used by:
Cause: The part is tilted at an angle exceeding 45 deg..
Remedy: Check that the nozzle is clean, and that the part is clean. Check that the correct part is being
picked.
------------------------------
Code: 1D0D0014
Display:
Used by:
Cause: There are more than 3 parts where the area to the left and right is not evenly shaped.
Remedy: Place these parts using Computer Vision #6.
------------------------------
Code: 1D0D0015
Display:
Used by:
Cause: The Y length is too long.
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
Code: 1D0D0016
第 1368 页
Display:
Used by:
Cause: There are more than 3 parts where the area to the left and right is not unevenly shaped.
Remedy: Place these parts using Computer Vision #6.
------------------------------
Code: 1D0D0017
Display:
Used by:
Cause: The Y length is too short.
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
Code: 1D0D0018
Display:
Used by:
Cause: The Y length is too long.
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
Code: 1D0D0019
Display:
Used by:
Cause: The X length is too short.
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
Code: 1D0D001A
Display:
Used by:
Cause: The X length is too long.
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
Code: 1D0D001B
Display:
Used by:
Cause: The X length is too long.
Remedy: Check the part length.
------------------------------
Code: 1D0D001C
Display:
Used by:
Cause: The Y length is too short.
Remedy: Check the part length.
------------------------------
Code: 1D0D001D
Display:
Used by:
Cause: Vision processing is not going well (the nozzle is dirty, the parts are not clean), the part is not
evenly shaped, or the value in Part data is smaller than the real part.
Remedy: If the nozzle and parts are clean, check that the parts are not incorrect.
------------------------------
Code: 1D0D001E
Display:
Used by:
第 1369 页