FUJI错误代码查询.pdf - 第1425页

------------------------------ Code: 1D11F??? Display: Used by: Cause: There was a logical error in the management program. Remedy: Check Part data. ------------------------------ Code: 1D120002 Display: Used by: Cause: …

100%1 / 5282
Cause: A lead could not be detected on the upper side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D11C4??
Display:
Used by:
Cause: An edge could not be detected on the left side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D11C5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D11C6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D11C7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D11D000
Display:
Used by:
Cause: There was too much picking slippage in the X direction.
Remedy: Check the part feeding orientation.
------------------------------
Code: 1D11D080
Display:
Used by:
Cause: There was too much picking slippage in the Y direction.
Remedy: Check the part feeding orientation.
------------------------------
Code: 1D11E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
第 1424 页
------------------------------
Code: 1D11F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D120002
Display:
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D124001
Display:
Used by:
Cause: The part cannot be detected.
Remedy: Check the Part data, check that the part is being picked properly, and check the image taken by
vision processing.
------------------------------
Code: 1D124002
Display:
Used by:
Cause: The image is not set (the nozzle is dirty or there is foreign matter on the parts), the part is mis-
shaped (the edges are uneven), and there is a large discrepancy between the part and the values set in
Part data.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D124003
Display:
Used by:
Cause: The part shape could not be detected.
Remedy: Check the image taken by vision processing.
------------------------------
Code: 1D124005
Display:
Used by:
Cause: The X length of the body is more than 15% larger than the value in Part data.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D124006
Display:
Used by:
Cause: The body size in the X direction is less than 85% of the value in Part data.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D124007
Display:
Used by:
Cause: The size of the part in the Y direction is too large.
Remedy: Check the part shape and the orientation of the part.
第 1425 页
------------------------------
Code: 1D124008
Display:
Used by:
Cause: The size of the part in the Y direction is too small.
Remedy: Check the part shape and the orientation of the part.
------------------------------
Code: 1D128002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D128100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D128110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D128111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D128112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D128113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D128114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
第 1426 页