Code: 1101B001 Display: 没有设定***。 Used by: XP141,XP241,XP341,XP142,XP242 Cause: 应设定的项目数值时为0,是字符串时为空格。 Remedy: 请设定为适当的数值。 ------------------------------ Code: 1101C000 Display: Used by: IP3 Cause: The sequence Q-axis angle…
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1501 to 1625.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C0D
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1626 to 1750.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C0E
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1751 to 1875.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C0F
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1876 to 2000.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11012001
Display: Same as code
Used by: GP551,GP6
Cause: An incorrect quantity of mark sequences has been included. There is only one board fiducial
sequence or mask fiducial sequence. Two or more sequences are required for proper execution of
compensation.
Remedy: Make sure that the production program contains an appropriate number of fiducial sequences.
As an exception to this rule, the program can be transmitted when neither board fiducial sequencesnor
mask fiducial sequences are present.
------------------------------
Code: 1101B000
Display: ***是范围出错。
Used by: XP141,XP241,XP341,XP142,XP242,GPX,NXTP
Cause: 在生产程序数据项目中设定了超过输入范围的数值。
Remedy: 请修正成输入范围内的数值。
------------------------------
第 59 页
Code: 1101B001
Display: 没有设定***。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 应设定的项目数值时为0,是字符串时为空格。
Remedy: 请设定为适当的数值。
------------------------------
Code: 1101C000
Display:
Used by: IP3
Cause: The sequence Q-axis angle is not a 90 deg.(+-3 deg.)increment, so the reflow sequence cannot be
performed.
Remedy: If the reflow sequence's Q-axis angle is not at 90 deg.(+-3 deg..) placing cannot be performed.
Set "Q" in N_data to a 90 deg. increment or set "RP" in N_data to reflow pass.
------------------------------
Code: 1101C001
Display:
Used by: IP3
Cause: There is no reflow temperature setting specified for the reflow sequence.
Remedy: A reflow temperature setting is necessary for the reflow sequence.
Therefore, set the appropriate sequence in the production program's "R_temp" setting in N_data or set "RP"
in N_data to reflow pass.
------------------------------
Code: 1101C002
Display:
Used by: IP3
Cause: There is no reflow time setting specified for the reflow sequence.
Remedy: A reflow time setting is necessary for the reflow sequence.
Therefore, set the appropriate sequence in the production program's "R_time" setting in N_data or set "RP"
in N_data to reflow pass.
------------------------------
Code: 1101C003
Display:
Used by: IP3
Cause: There is a reflow sequence in the object production program, but the production environment
data name has not been set.
Remedy: A production environment data name is necessary if there is a reflow sequence. Input a
production environment data name in the production program's "58.Reflow_data_name" in Machine_data.
Otherwise, set "RP" in N_data to reflow pass for all sequences.
------------------------------
Code: 1101C010
Display:
Used by: IP3
Cause: The device number in placing sequence data is out of range. This error applies to sequences 1 to
20.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C011
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 21
to 40.
第 60 页
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C012
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 41
to 60.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C013
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 61
to 80.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C014
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 81
to 100.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C015
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 101
to 120.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C016
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 121
to 140.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C017
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 141
to 160.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C018
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 161
to 180.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------